Current Transformers Australia

637 products

  • Last stock! Rishabh Instruments Split Core AC Current Transformer Rish Xmer 155/80 2000/5 Split Core CT Class 0.5 20VA FE-Rish Xmer 155/80 2000/5 SCCT Class 0.5 20VA Rish Xmer 155/80 2000/5 Split Core CT Class 0.5 20VA, 85 x 125mm Aperture

    Rish Xmer 155/80 2000/5 Split Core CT Class 0.5 20VA, 85 x 125mm Aperture

    3 pcs in stock

    Rishabh Xmer CT Split 155/80 2000/5 Class 0.5 20VA Series Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Rishabh Part Number Rish Xmer 155/80 2000/5 SCCT Class 0.5 20VA Technology Split Core AC Current Transformer Ratio 2000/5 Aperture Size 85 x 125mm Burden 45VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 2000Amp x 1.2 Termination Style Screw Unit Weight 1000g Factory Pack Qty 9   Datasheet Product Datasheet  

    3 pcs in stock

    $295.00
    $348.10 inclGST

  • SCT-F10-75, 0.333v, 75Amp Measurement, Class 1 Split Core CT's Class 1 SCT-F10-75, 0.333v, 75Amp Measurement, Class 1 Split Core CT's Class 1

    SCT-F10-75, 0.333v, 75Amp Measurement, Class 1 Split Core CT's Class 1

    144 pcs in stock

    Fastron Electronics SCT-10-75, 75 Amp, 0.333v Class 1 Series Current Transformer Features Quick Release Split Core System Cable Mount 0.333v Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F10-75 Technology Split Core AC Current Transformer Ratio 75/0.333v Aperture Size ø 8 mm VA Rating N/A Accuracy Class Class 1 Output 0.333v (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 75Amp x 1.2 Termination Style 0.5M Flying Leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide

    144 pcs in stock

    $39.00
    $46.02 inclGST

  • CT 300/5 Class 0.5 10VA 62/30 (50), Current Transformer 300/5Amp CT 10VA HIGH BURDEN, Class 0.5 CT 300/5 Class 0.5 10VA 62/30 (50), Current Transformer 300/5Amp CT 10VA HIGH BURDEN, Class 0.5

    CT 300/5 Class 0.5 10VA 62/30 (50), Current Transformer 300/5Amp CT 10VA HIGH BURDEN, Class 0.5

    42 pcs in stock

    Rishabh CT 300/5 Class 0.5 10VA 62/30 (50), 300/5 Amp, Class 0.5 Current Transformer HIGH BURDEN Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number CT 300/5 Class 0.5 10VA 62/30 (50) Technology AC Current Transformer Ratio 300/5 Aperture Size 28mm or 10x30mm Busbar VA Rating 30VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 300Amp x 1.2 Termination Style Screw Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet

    42 pcs in stock

    $49.90
    $58.88 inclGST

  • FES521-FP-420E, Split Core AC Current Transducer, Multirange 10A, 20A, 50A, Average RMS 4-20mA Output. 1% Accuracy FES521-FP-420E, AC Current Transducer, Multirange 10A,20A, 50A, Average RMS 4-20mA Output. 2% Accuracy-AC Current Transformer with Process Output-Fastron Electronics-Fastron Electronics Store

    FES521-FP-420E, Split Core AC Current Transducer, Multirange 10A, 20A, 50A, Average RMS 4-20mA Output. 1% Accuracy

    75 pcs in stock

    Fastron FES521-FP-420E, Split Core AC Current Transducer, Multirange 10A, 20A, 50A, Average RMS 4-20mA Output. 1% Accuracy (FCS521-FP-420E) Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 4-20mA True RMS output Features True RMS 4-20mA output Multirange selector Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Highly accurate low current measurement down to 1Amp High isolation between primary and secondary circuits Easy installation Applications Fault Detection Motor or Fan Protection Application Domain Energy and Automation Specification Fastron Part Number FES521-FP-420E Technology Split Core AC Current Transducer Range Selectable 0-10Amp, 0-20Amp, 0-50Amp via jumper Supply Voltage Self Powered Load Current (RMS) 1Amp to 50 Amp Output 4-20mA Average RMS Isolation 2kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C Accuracy 1% Termination Style Screw Terminals Unit Weight 200g Certifications UL E320368, CE, Rohs compliant Datasheet Product Datasheet Installation Guide

    75 pcs in stock

    $79.00
    $93.22 inclGST

  • FESCT-32-250-0.333V, 250Amp measurement Split Core CT's, w/1M Flying leads, 32x32mm Aperture-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store FESCT-32-250-0.333V, 250Amp measurement Split Core CT's, w/1M Flying leads, 32x32mm Aperture-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    FESCT-32-250-0.333V, 250Amp measurement Split Core CT's, Class 1, w/1M Flying leads, 32x32mm Aperture

    12 pcs in stock

    Fastron Electronics FESCT-32-250-0.333V, 250Amp measurement Split Core CT's, w/1M Flying leads, 32x32mm Aperture, 0.333v Class 1 Series Current Transformer Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/2kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number FESCT-32-250-0.333V Technology Split Core AC Current Transformer Ratio 250/0.333V Aperture Size 32 x 32mm VA Rating N/A Accuracy Class Class 1 Output 0.333VAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 250Amp x 1.2 Termination Style 1M Twisted Pair 0.34mm^2 Unit Weight 350g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    12 pcs in stock

    $80.00
    $94.40 inclGST

  • Last stock! MCT-0024-250, 250 Amp, Loop Powered AC Current Transducer, Average RMS, 4-20mA Output, Accuracy +/-2% (Ripple)

    MCT-0024-250, 250 Amp, Loop Powered AC Current Transducer, Average RMS, 4-20mA Output, Accuracy +/-2% (Ripple)

    3 pcs in stock

    Magnelab MCT-0024-250, 250 Amp, Loop Powered AC Current Transducer, Average RMS, 4-20mA Output Features Average RMS Output Split Core 4-20mA Current Output Cable Mounting 20-30VDC Loop Powered Isolated plastic case recognised according to UL94-V0 UL, CE, ROHS Approved Advantages Large aperture for cable up to ⌀ 24mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Motor Control Actuators Lamp Failure Specification Magnelab Part Number MCT-0024-250 Technology AC Current Transducer Protection Class IP50 Supply Voltage 20-30VDC Loop Powered (10mA) Load Current (RMS) 250 Amp Output 4-20mA (Average RMS) Isolation 3.5kV (AC, 50Hz, 1 min) Bandwidth 50 - 60Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy +/-2% Ripple on output Termination Style Screw Aperture 24mm Approvals UL, CE, ROHS Unit Weight 200g Factory Pack Qty 6   Datasheet Product Datasheet  

    3 pcs in stock

    $283.50
    $334.53 inclGST

  • CT 250/5, Class 0.5 5VA 50/21 (30) Current Transformer CT 250/5, Class 0.5 5VA 50/21 (30) Current Transformer

    CT 250/5, Class 0.5 5VA 50/21 (30) Current Transformer

    36 pcs in stock

    Rishabh CT 250/5 Class 0.5 5VA 50/21 (30) Series Current Transformer Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number CT 250/5 Class 0.5 5VA 50/21 (30) Technology AC Current Transformer Ratio 250/5 Aperture Size ⌀ 21mm or 20x10mm Busbar VA Rating 5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 250Amp x 1.2 Termination Style Screw Unit Weight 300g Factory Pack Qty 9 Datasheet Product Datasheet

    36 pcs in stock

    $34.00
    $40.12 inclGST

  • FESCT-51-600-0.333V, 600Amp measurement Split Core CT's, w/1M Flying leads, 51x51mm Aperture-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store FESCT-51-600-0.333V, 600Amp measurement Split Core CT's, w/1M Flying leads, 51x51mm Aperture-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    FESCT-51-600-0.333V, 600Amp measurement Split Core CT's, Class 1, w/1M Flying leads, 51x51mm Aperture

    18 pcs in stock

    Fastron Electronics FESCT-51-600-0.333V, 600Amp measurement Split Core CT's, w/1M Flying leads, 51x51mm Aperture Class 1 Series Current Transformer Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Electronics Part Number FESCT-51-600-0.333V Technology Split Core AC Current Transformer Ratio 600/0.333V Aperture Size 51 x 51mm VA Rating N/A Accuracy Class Class 1 Output 0.333VAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 600Amp x 1.2 Termination Style 1M Twisted Pair 0.34mm^2 Unit Weight 950g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    18 pcs in stock

    $105.00
    $123.90 inclGST

  • Last stock! Rishabh Instruments Split Core AC Current Transformer Xmer CT Split 125/50SC 250/5 Class 1, 50 x 80mm Aperture FE-Xmer CT Split 125/50SC 250/5

    Xmer CT Split 125/50SC 250/5 Class 1, 1VA 55 x 85mm Aperture

    3 pcs in stock

    Rishabh Xmer CT Split 125/50SC 250/5 Class 1, 1VA Series Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Rishabh Part Number Xmer CT Split 125/50SC 250/5 Class 1 1VA Technology Split Core AC Current Transformer Ratio 250/5 Aperture Size 55 x 85mm VA Rating 1VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 250Amp x 1.2 Termination Style Screw Unit Weight 1.25kg Factory Pack Qty 9   Datasheet Product Datasheet

    3 pcs in stock

    $155.00
    $182.90 inclGST

  • Last stock! AT 5 B420L, AC Current Transformer, loop powered, 5 Amp Average RMS 4-20mA output

    AT 5 B420L, AC Current Transformer, loop powered, 5 Amp Average RMS 4-20mA output

    1 pcs in stock

    LEM AT 5 B420L, AC Current Transformer, loop powered, 5 Amp Average RMS 4-20mA output Features Average RMS Output Split Core 4-20mA Current Output Cable Mounting 20-30VDC Loop Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ? 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Motor Control Actuators Lamp Failure Specification LEM Part Number AT 5 B420L Technology AC Current Transformer Protection Class IP50 Supply Voltage 20-30VDC Loop Powered (10mA) Load Current (RMS) 5 Amp Maximum Measurement Current (RMS) 6 Amp Output 4-20mA (Average RMS) Isolation 3.5kV (AC, 50Hz, 1 min) Bandwidth 55 - 65Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy 1.5% Aperture ? 16mm Termination Style Screw Approvals CE,UL,ROHS Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet

    1 pcs in stock

    $237.50
    $280.25 inclGST

  • Northern Design Electronics Ltd AC Current Transformer with Process Output XD-I420-1, AC Current Transducer, Average RMS, Ipn = Selectable 5,10,15,20,25 Amp, 4-20mA out, 16-36VDC Loop powered FE-XD-I420-1

    XD-I420-1, AC Current Transducer, Average RMS, Ipn = Selectable 5,10,15,20,25 Amp, 4-20mA out, 16-36VDC Loop powered

    15 pcs in stock

    Northern Design XD-I420-1, AC Current Transducer, Average RMS, Ipn = Selectable 5,10,15,20,25 Amp, 4-20mA out, 16-36VDC Loop powered Features Ipn = Selectable 5,10,15,20,25 Amp Average RMS Output 4-20mA Current Output Din Rail Mounting 16-36VDC Loop Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀ 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Earth Leakage Measurement Motor Control Actuators Lamp Failure Specification Northern Design Part Number XD-I420-1 Technology AC Current Transformer Protection Class IP50 Supply Voltage 16-36VDC Loop Powered (10mA) Load Current (RMS) Selectable 5,10,15,20,25 Amp Output 4-20mA Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 55 - 65Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy Class 1 Termination Style Screw Unit Weight 180g Factory Pack Qty 6   Datasheet Product Brochure Product Manual  

    15 pcs in stock

    $179.00
    $211.22 inclGST

  • SCT-F16-50-1A, 50/1A Measurement, Class 1 Split Core CT's SCT-F16-50-1A, 50/1A Measurement, Class 1 Split Core CT's

    SCT-F16-50-1A, 50/1A Measurement, Class 1 Split Core CT's

    39 pcs in stock

    Fastron Electronics SCT-F16-50-1A, 50/1A Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 1 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F16-50-1A Technology Split Core AC Current Transformer Ratio 50/1A Aperture Size ø 15 mm VA Rating 1VA Accuracy Class Class 1 Output 1 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 50Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    39 pcs in stock

    $48.00
    $56.64 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account