Current Transformers Australia

633 products

  • CT 50/5 Class 1 10VA 74W (45) Series Current Transformer, HIGH BURDEN, Wihtout Aperture CT 50/5 Class 1 10VA 74W (45) Series Current Transformer, HIGH BURDEN, Wihtout Aperture

    CT 50/5 Class 1 10VA 74W (45) Series Current Transformer, HIGH BURDEN, Wihtout Aperture

    12 pcs in stock

    Rishabh CT 50/5 Class 1 10VA 74W (45) Series Current Transformer, HIGH BURDEN, Without Aperture Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Rishabh Part Number CT 50/5 Class 1 10VA 74W (45) Technology AC Current Transformer Ratio 50/5 Aperture Size No Apeture. Cable passed through P1(Incoming) and P2(Load Side) terminals VA Rating 10VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 50Amp x 1.2 Termination Style Screw Unit Weight 450g Factory Pack Qty 9   Datasheet Product Datasheet  

    12 pcs in stock

    $65.00
    $76.70 inclGST

  • SCT-F16-90-90mA/SP1, Split Core CT's 90 Measurement, Class 1, 90mA output SCT-F16-100-5A, 120/5Amp Measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F16-90-90mA/SP1, Split Core CT's 90 Measurement, Class 1, 90mA output

    Out of stock

    Fastron Electronics SCT-F16-90-90mA/SP1, Split Core CT's 90 Measurement, 90mA Output , 100Amp measurement Split Core Current Transformer Features Quick Release Split Core System Cable Mount 500mA Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F16-90-90mA/SP1 Technology Split Core AC Current Transformer Ratio 90A/90mA Aperture Size ø 15 mm VA Rating 1VA Accuracy Class 5% Output 1 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    Out of stock

    $49.00
    $57.82 inclGST

  • SCT-F10-10-500mA, 10Amp/500mA Measurement, Class 1 Split Core CT's, 5% Accuracy SCT-F10-10-500mA, 10Amp/500mA Measurement, Class 1 Split Core CT's, 5% Accuracy

    SCT-F10-10-500mA, 10Amp/500mA Measurement, Class 1 Split Core CT's, 5% Accuracy

    Out of stock

    Fastron Electronics SCT-F10-10-100mA, 10Amp/100mA measurement Split Core CT's Class B Features Quick Release Split Core System Cable Mount 500mA Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F10-10-500mA Technology Split Core AC Current Transformer Ratio 10/0.333v Aperture Size ø 8 mm VA Rating N/A Accuracy Class Class 1 Output 0.333v (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 10Amp x 1.2 Termination Style 0.5M Flying Leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide

    Out of stock

    $47.30
    $55.81 inclGST

  • CT 300/5 Class 0.5 15VA 86/40 (45), Current Transformer 300/5Amp CT 15VA HIGH BURDEN, Class 0.5,  Aperture or 11x41mm Busbar CT 300/5 Class 0.5 15VA 86/40 (45), Current Transformer 300/5Amp CT 15VA HIGH BURDEN, Class 0.5,  Aperture or 11x41mm Busbar

    CT 300/5 Class 0.5 15VA 86/40 (45), Current Transformer 300/5Amp CT 15VA HIGH BURDEN, Class 0.5, Aperture or 11x41mm Busbar

    15 pcs in stock

    Rishabh CT 300/5 Class 0.5 15VA 86/40 (45), Current Transformer 300/5Amp CT 15VA, Class 0.5 HIGH BURDEN Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number CT 300/5 Class 0.5 15VA 86/40 (45) Technology AC Current Transformer Ratio 300/5 Aperture Size 36mm or 11x41mm Busbar VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Moun Operating Temperature Range -30°C / 85°C Continuous Current (max) 300Amp x 1.2 Termination Style Screw Unit Weight 300g Factory Pack Qty 9 Datasheet Product Datasheet

    15 pcs in stock

    $66.70
    $78.71 inclGST

  • CT 400/5 Class 1 20VA 86/40 (45), Current Transformer 400/5Amp CT 20VA HIGH BURDEN, Class 1 CT 400/5 Class 1 20VA 86/40 (45), Current Transformer 400/5Amp CT 20VA HIGH BURDEN, Class 1

    CT 400/5 Class 1 20VA 86/40 (45), Current Transformer 400/5Amp CT 20VA HIGH BURDEN, Class 1

    Out of stock

    Rishabh CT 400/5 Class 1 20VA 86/40 (45), Current Transformer 400/5Amp CT 20VA, Class 1 HIGH BURDEN Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number CT 400/5 Class 1 20VA 86/40 (45) Technology AC Current Transformer Ratio 400/5 Aperture Size 36mm or 11x41mm Busbar VA Rating 20VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Moun Operating Temperature Range -30°C / 85°C Continuous Current (max) 400Amp x 1.2 Termination Style Screw Unit Weight 300g Factory Pack Qty 9 Datasheet Product Datasheet

    Out of stock

    $66.70
    $78.71 inclGST

  • CT 500/5 Class 0.5 15VA 86/40 (45), Current Transformer 500/5Amp CT 30VA HIGH BURDEN, Class 0.5, 11 x 41mm or ø36mm Aperture CT 500/5 Class 0.5 15VA 86/40 (45), Current Transformer 500/5Amp CT 30VA HIGH BURDEN, Class 0.5, 11 x 41mm or ø36mm Aperture

    CT 500/5 Class 0.5 15VA 86/40 (45), Current Transformer 500/5Amp CT 30VA HIGH BURDEN, Class 0.5, 11 x 41mm or ø36mm Aperture

    15 pcs in stock

    Rishabh CT 500/5 Class 0.5 15VA 86/40 (45), Current Transformer 500/5Amp CT 15VA, Class 0.5 HIGH BURDEN Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number CT 500/5 Class 0.5 15VA 86/40 (45) Technology AC Current Transformer Ratio 500/5 Aperture Size 36mm or 11x41mm Busbar VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Moun Operating Temperature Range -30°C / 85°C Continuous Current (max) 500Amp x 1.2 Termination Style Screw Unit Weight 300g Factory Pack Qty 9 Datasheet Product Datasheet

    15 pcs in stock

    $66.70
    $78.71 inclGST

  • SCT-F36-600, 0.333V, 600Amp Measurement, Class 1 Split Core CT's Class 1, 35mm Aperture SCT-F36-500, 0.333V, 500Amp measurement Split Core CT's Class 1, 35mm Aperture-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F36-600, 0.333V, 600Amp Measurement, Class 1 Split Core CT's Class 1, 35mm Aperture

    145 pcs in stock

    Fastron Electronics SCT-F36-600, 0.333V, 600Amp measurement Split Core CT's Class 1, 35mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-600 Technology Split Core AC Current Transformer Ratio 600/0.333V Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 600Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    145 pcs in stock

    $66.50
    $78.47 inclGST

  • CT105F-100/5-2.5/1 Class 1, 2.5VA 100 Amp, 5 Amp Output, 3 Phase Current Transformer, With Feet Mount-3 Phase AC Current Transformer-Hobut Howard Butler-Fastron Electronics Store

    CT105F-100/5-2.5/1 Class 1, 2.5VA 100 Amp, 5 Amp Output, 3 Phase Current Transformer, With Feet Mount

    10 pcs in stock

    Hobut CT105F-100/5-2.5/1 Class 1, 2.5VA 100 Amp, 5 Amp Output, 3 Phase Current Transformer, With Feet Mount for MCCB Mounting Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Hobut Part Number CT105F-100/5-2.5/1 Technology AC Current Transformer Ratio 100/5 Aperture Size 21 x 25mm VA Rating 2.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 100Amp x 1.2 Termination Style Screw Unit Weight 450g Factory Pack Qty 9   Datasheet Product Datasheet  

    10 pcs in stock

    $103.00
    $121.54 inclGST

  • SCT-F16-175, 175/0.333V MeasurementSplit Core CCT's, 16mm Aperture-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store SCT-F16-175, 175/0.333V MeasurementSplit Core CCT's, 16mm Aperture-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F16-175, 175/0.333V Measurement, Class 1Split Core CCT's, 16mm Aperture

    Out of stock

    Fastron Electronics SCT-F16-175, 0.333V Output, 175Amp measurement Split Core Current Transformer, 16mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-175 Technology Split Core AC Current Transformer Ratio 175/0.333V Aperture Size ø 15 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 175Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide

    Out of stock

    $45.00
    $53.10 inclGST

  • SCT-F16-25-1A, 25/1Amp Measurement, Class 1 Split Core CT's SCT-F16-25-1A, 25/1Amp Measurement, Class 1 Split Core CT's

    SCT-F16-25-1A, 25/1Amp Measurement, Class 1 Split Core CT's

    25 pcs in stock

    Fastron Electronics SCT-F16-25-1A, 1 Amp Output, 25Amp measurement Split Core Current Transformer Features Quick Release Split Core System Cable Mount 1 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-25-1A Technology Split Core AC Current Transformer Ratio 25/1A Aperture Size ø 15 mm VA Rating 1VA Accuracy Class Class 1 Output 1 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 25Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide

    25 pcs in stock

    $48.00
    $56.64 inclGST

  • Last stock! SCT-F16-50-100mA, 50/100mA Measurement, Class 1 Split Core CT's SCT-F16-50-100mA, 50/100mA Measurement, Class 1 Split Core CT's

    SCT-F16-50-100mA, 50/100mA Measurement, Class 1 Split Core CT's

    3 pcs in stock

    Fastron Electronics SCT-F16-50-100mA, 50/100mA Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 100mAmp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F16-50-100mA Technology Split Core AC Current Transformer Ratio 50/100mA Aperture Size ø 15 mm VA Rating 1VA Accuracy Class Class 1 Output 1 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 50Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    3 pcs in stock

    $48.00
    $56.64 inclGST

  • SCT-F16-120, 120/0.333V Measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store SCT-F16-120, 120/0.333V Measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F16-120, 120/0.333V Measurement, Class 1 Split Core CT's

    42 pcs in stock

    Fastron Electronics SCT-F16-120-5A, 0.333V Output, 120Amp measurement Split Core Current Transformer, 16mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-120 Technology Split Core AC Current Transformer Ratio 120/0.333V Aperture Size ø 15 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 120Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide

    42 pcs in stock

    $45.00
    $53.10 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account