Current Transformers Australia

679 products

  • SCT-F36-400-40mA, 40mA, 400Amp Measurement, Class 1 Split Core CT's SCT-F36-400-5A, 5 Amp, 400Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F36-400-40mA, 40mA, 400Amp Measurement, Class 1 Split Core CT's

    78 pcs in stock

    Fastron Electronics SCT-F36-400-40mA, 40mA, 400Amp Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 40mA Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F36-400-40mA Technology Split Core AC Current Transformer Ratio 400/040 Amp Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output .40 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 400Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    78 pcs in stock

    $66.50
    $78.47 inclGST

  • SCT-F24-100-5A, 5 Amp, 100Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store SCT-F24-100-5A, 5 Amp, 100Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F24-250-40mA, 40mA, 250Amp Measurement, Class 1 Split Core CT's

    107 pcs in stock

    Fastron Electronics SCT-F24-250-40mA, 40mA, 250Amp measurement Split Core CT's's, Class 1 Series Current Transformer Features Quick Release Split Core System Cable Mount 40mA Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F24-250-40mA Technology Split Core AC Current Transformer Ratio 250/0.40 Amp Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 40mAmp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 250Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    107 pcs in stock

    $50.50
    $59.59 inclGST

  • SCT-F50-250-5A, 5 Amp, 250Amp measurement Split Core CT's SCT-F50-250-5A, 5 Amp, 250Amp measurement Split Core CT's

    SCT-F50-250-5A, 5 Amp, 250Amp measurement Split Core CT's

    74 pcs in stock

    Fastron Electronics SCT-F50-250-5A, 5 Amp, 250Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F50-250-5A Technology Split Core AC Current Transformer Ratio 250/5 Amp Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 250Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    74 pcs in stock

    $110.55
    $130.45 inclGST

  • SCT-F24-100, 0.333v, 100Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store SCT-F24-100, 0.333v, 100Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F24-100, 0.333v, 100Amp Measurement, Class 1 Split Core CT's

    341 pcs in stock

    Fastron Electronics SCT-F24-100, 100 Amp, 0.333v Class 1 Series Current Transformer Features Quick Release Split Core System Cable Mount 0.333v Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F24-100 Technology Split Core AC Current Transformer Ratio 100/0.333v Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 0.333v (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    341 pcs in stock

    $44.20
    $52.16 inclGST

  • FP125125P, 1250/5 Amp Split Core CT, Class 0.5, 7.5VA, 80 x 120mm Aperture, Dimensions 145 x 37 x 200mm FP125125P, 1250/5 Amp Split Core CT, Class 0.5, 7.5VA, 80 x 120mm Aperture, Dimensions 145 x 37 x 200mm

    FP125125P, 1250/5 Amp Split Core CT, Class 0.5, 7.5VA, 80 x 120mm Aperture, Dimensions 145 x 37 x 200mm

    9 pcs in stock

    FP125125P, 1250/5 Amp Split Core CT, Class 0.5. 7.5VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Electronics Part Number FP125125P Technology Split Core AC Clip On Current Transformer Ratio 1250/5 Aperture Size 85 x 120mm VA Rating 7.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 1250Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1   Datasheet Product Datasheet Installation Guide  

    9 pcs in stock

    $137.00
    $161.66 inclGST

  • FP060080P, 600/5 Amp Split Core CT, Class 0.5 2.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm FP060080P, 600/5 Amp Split Core CT, Class 0.5 2.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm

    FP060080P, 600/5 Amp Split Core CT, Class 0.5 2.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm

    Out of stock

    Free Aus Post Shipping for $300 Spend

    FP060080P, 600/5 Amp Split Core CT, Class 1 3VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number FP060080P Technology Split Core AC Clip On Current Transformer Ratio 600/5 Aperture Size 50 x 80mm VA Rating 2.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 600Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1   Datasheet Product Datasheet Installation Guide  

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $102.00
    $120.36 inclGST

  • SCT-F36-500-5A, 5 Amp, 500Amp Measurement, Class 1 Split Core CT's SCT-F36-500-5A, 5 Amp, 500Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F36-500-5A, 5 Amp, 500Amp Measurement, Class 1 Split Core CT's

    66 pcs in stock

    Fastron Electronics SCT-F36-500-5A, 5 Amp, 500Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F36-500-5A Technology Split Core AC Current Transformer Ratio 500/5 Amp Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 400Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    66 pcs in stock

    $66.50
    $78.47 inclGST

  • FP080125P, 800/5 Amp Split Core CT, Class 0.5 2.5VA, 83 x 123.5mm Aperture, Dimensions 157 x 198 x 36mm-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store FP080125P, 800/5 Amp Split Core CT, Class 0.5, 2.5VA, 80 x 120mm Aperture, Dimensions 145 x 37 x 200mm

    FP080125P, 800/5 Amp Split Core CT, Class 0.5, 2.5VA, 80 x 120mm Aperture, Dimensions 145 x 37 x 200mm

    22 pcs in stock

    FP080125P, 800/5 Amp Split Core CT, Class 0.5, 2.5VA, 80 x 120mm Aperture, Dimensions 145 x 37 x 200mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Electronics Part Number FP080125P Technology Split Core AC Clip On Current Transformer Ratio 800/5 Aperture Size 85 x 120mm VA Rating 2.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 800Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1   Datasheet Product Datasheet Installation Guide  

    22 pcs in stock

    $137.00
    $161.66 inclGST

  • FP100080P, 1000/5 Amp Split Core CT, Class 0.5, 5VA Series Clip On Current Transformer FP100080P, 1000/5 Amp Split Core CT, Class 0.5, 5VA Series Clip On Current Transformer

    FP100080P, 1000/5 Amp Split Core CT, Class 0.5, 5VA Series Clip On Current Transformer

    10 pcs in stock

    FP100080P, 1000/5 Amp Split Core CT, Class 0.5, 5VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number FP10080P Technology Split Core AC Clip On Current Transformer Ratio 1000/5 Aperture Size 50 x 80mm VA Rating 5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 800Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1   Datasheet Product Datasheet Installation Guide  

    10 pcs in stock

    $102.00
    $120.36 inclGST

  • SCT-F50-500-5A, 5 Amp, 500Amp measurement Split Core CT's SCT-F50-500-5A, 5 Amp, 500Amp measurement Split Core CT's

    SCT-F50-500-5A, 5 Amp, 500Amp measurement Split Core CT's

    69 pcs in stock

    Fastron Electronics SCT-F50-500-5A, 5 Amp, 500Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F50-500-5A Technology Split Core AC Current Transformer Ratio 500/5 Amp Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 500Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    69 pcs in stock

    $110.55
    $130.45 inclGST

  • SCT-F50-300-5A, 5 Amp, 300Amp measurement Split Core CT's SCT-F50-300-5A, 5 Amp, 300Amp measurement Split Core CT's

    SCT-F50-300-5A, 5 Amp, 300Amp measurement Split Core CT's

    71 pcs in stock

    Fastron Electronics SCT-F50-300-5A, 5 Amp, 300Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F50-300-5A Technology Split Core AC Current Transformer Ratio 300/5 Amp Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 300Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    71 pcs in stock

    $110.55
    $130.45 inclGST

  • FP063080P, 630/5 Amp Split Core CT, Class 0.5 3VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm FP063080P, 630/5 Amp Split Core CT, Class 0.5 3VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm

    FP063080P, 630/5 Amp Split Core CT, Class 0.5 3VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm

    Out of stock

    Free Aus Post Shipping for $300 spend

    FP063080P, 630/5 Amp Split Core CT, Class 1 3VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number FP063080P Technology Split Core AC Clip On Current Transformer Ratio 630/5 Aperture Size 50 x 80mm VA Rating 3VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 630Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1   Datasheet Product Datasheet Installation Guide  

    Out of stock

    Free Aus Post Shipping for $300 spend

    $102.00
    $120.36 inclGST

Login

Forgot your password?

Don't have an account yet?