Current Transformers Australia
-
FP025080P/1A, 250/1 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm
FP025080P/1A, 250/1 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number FP025080P/1A Technology Split Core AC Clip On Current Transformer Ratio 250/1 Aperture Size 50 x 80mm VA Rating 1.5VA Accuracy Class Class 1 Output 1 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 250Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1  Datasheet Product Datasheet Installation Guide Â
$112.00
$132.16 inclGST -
FP010030P/1A, 100/1 Amp Split Core CT, Class 1, 1VA Clip On AC Current Transformer, 20 x 30mm Aperture, Dimension 90 x 40 x 110mm
FP010030P/1A, 100/1 Amp Split Core CT, Class 1, 1VA Clip On AC Current Transformer, 20 x 30mm Aperture, Dimension 90 x 40 x 110mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number FP010030P/1A Technology Split Core AC Clip On Current Transformer Ratio 100/1 Aperture Size 20 x 30mm VA Rating 1VA Accuracy Class Class 1 Output 1 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 100Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1  Datasheet Product Datasheet Installation Guide Â
$92.00
$108.56 inclGST -
SCT-F16-50-16.6mA, 50/16.6mA Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F16-50-16.6mA, 50/16.6mA Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 16.6mA Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number SCT-F16-50-16.6mAmA Technology Split Core AC Current Transformer Ratio 50/16.6mA Aperture Size ø 10 mm VA Rating N/A Accuracy Class Class 1 Output 16.6mA (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9  Datasheet Product Datasheet Application Notes Installation Guide
$45.00
$53.10 inclGST -
FESCT-6000-5000-0.333V, 5000Amp 0.333V Class 1 Measurement Split Core CT's, w/1M Flying Leads, 153x157mm Aperture
Fastron Electronics FESCT-6000-5000-0.333V, 5000Amp 0.333V Class 1 Measurement Split Core CT's, w/1M Flying Leads, 153x157mm Aperture Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Electronics Part Number FESCT-6000-5000-0.333V Technology Split Core AC Current Transformer Ratio 5000/0.333V Aperture Size 153x157mm VA Rating N/A Accuracy Class Class 1 Output 0.333VAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 5000Amp x 1.2 Termination Style 1M Flying leads Unit Weight 3000g Factory Pack Qty 9  Datasheet Product Datasheet Application Notes Installation Guide
$249.00
$293.82 inclGST -
FESCT-6000-4000-0.333V, 4000Amp 0.333V Class 1 Measurement Split Core CT's, w/terminals, 153x157mm Aperture
Fastron Electronics FESCT-6000-4000-0.333V, 4000Amp 0.333V Class 1 Measurement Split Core CT's, w/terminals, 153x157mm Aperture Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Electronics Part Number FESCT-6000-4000-0.333V Technology Split Core AC Current Transformer Ratio 4000/0.333V Aperture Size 153x157mm VA Rating N/A Accuracy Class Class 1 Output 0.333VAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 4000Amp x 1.2 Termination Style Terminals Unit Weight 3000g Factory Pack Qty 9  Datasheet Product Datasheet Application Notes Installation Guide
$249.00
$293.82 inclGST -
FESCT-19-050-0.333V, 50Amp measurement Split Core CT's, Class 1, w/1M Flying leads, 19x19mm Aperture
Fastron Electronics FESCT-19-050-0.333V, 50Amp measurement Split Core CT's, w/1M Flying leads, 19x19mm Aperture, Class 1 Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number FESSCT-19-050-0.333V Technology Split Core AC Current Transformer Ratio 50/0.333V Aperture Size 19 x 19mm VA Rating N/A Accuracy Class Class 1 Output 0.333VAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 50Amp x 1.2 Termination Style 1M Twisted Pair 0.34mm^2 Unit Weight 350g Factory Pack Qty 9  Datasheet Product Datasheet Application Notes Installation Guide
$69.00
$81.42 inclGST -
CT 40/5 Class 1 1VA 50/14 (50) Current Transformer
Rishabh CT 40/5 Class 1 1VA 50/14 (50) Current Transformer Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Rishabh Part Number CT 40/5 Class 1 1VA 50/14 (50)) Technology AC Current Transformer Ratio 40/5 Aperture Size ⌀ 14mm VA Rating 1VA Accuracy Class Class 01 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 40Amp x 1.2 Termination Style Screw Unit Weight 300g Factory Pack Qty 9  Datasheet Product Datasheet Â
$26.00
$30.68 inclGST -
CT 60/5 Class 0.5 1.5VA 50/21 (50) Current Transformer
Rishabh CT 60/5 Class 0.5 1.5VA 50/21 (50) Series Current Transformer Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Rishabh Part Number CT 60/5 Class 0.5 1.5VA 50/21 (50) Technology AC Current Transformer Ratio 6/5 Aperture Size ⌀ 21mm or 20x10mm Busbar VA Rating 1.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 60Amp x 1.2 Termination Style Screw Unit Weight 300g Factory Pack Qty 9  Datasheet Product Datasheet Â
$36.00
$42.48 inclGST -
CRJ-31, Converter for 3 x HY-2.0 to 3 Phase RJ12 kWh Meter Connection
Eastron Europe CRJ-31, Converter for 3 x HY-2.0 to 3 Phase RJ12 kWh Meter Connection Features Quick Release Split Core System Cable Mount 100mAmp or 100mV input and Output Applications Eastron Modular Metering Equipment Accessories RJ12cable-1SW  Specification Fastron Part Number CRJ-31 Technology Splitter for HY2.0 Split Core AC Current Transformers Rating 100mV/100mA Bandwidth 50-60Hz Operating Temperature Range -15°C / 45°C Termination Style 1M Flying leads with RJ12 Connector Unit Weight 50g Factory Pack Qty 10  Application Notes Installation Guide CRJ-31 Connector User Guide
$10.00
$11.80 inclGST -
SCT-F36-600-040A, 40mA, 600Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F36-600-040A, 40mA, 600Amp Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 40mA Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-600-040A Technology Split Core AC Current Transformer Ratio 600/40mA Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 600Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
SCT-F36-500-040A, 40mA, 500Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F36-500-040A, 40mA, 500Amp Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 40mA Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-500-040A Technology Split Core AC Current Transformer Ratio 500/40mA Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 500Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
FP030030P, 300/5 Amp Split Core CT, Class 0.5 2.5VA Clip On AC Current Transformer, 20 x 30mm Aperture, Dimension 90 x 40 x 110mm
Fastron FP030030P, 300/5 Amp Split Core CT, Class 0.5 2.5VA AC Clip On Current Transformer, 20 x 30mm Aperture, Dimension 90 x 40 x 110mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number FP030030P Technology Split Core AC Clip On Current Transformer Ratio 300/5 Aperture Size 20 x 30mm VA Rating 1.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 300Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1  Datasheet Product Datasheet Installation Guide Â
$85.00
$100.30 inclGST