How to Test Klixon Sensata 4CR Series Motor Start Relays

How to Test Klixon Sensata 4CR Series Motor Start Relays

, by Daniel Rehe, 1 min reading time

How to Test Klixon Sensata 4CR Series Motor Start Relays

How to Test Klixon Sensata 4CR Series Motor Start Relays

4CR Single Circuit Relay

For single circuit relay, apply pick-up current through terminal #3 and #4, then check if the circuit between terminal #2 and #4 is close, then remove current, check if the circuit between terminal #2 and #4 is open.

 

4CR Two Circuit Relay

For two circuit relay, apply pick-up current through terminal #3 and #1, then check if the circuit between terminal #2 and #4 is close, then remove current, check if the circuit between terminal #2 and #4 is open.

Note: 4CR relay can only be used for AC motors, it can’t be used for DC.

For 4CR Catalogue Download Here. 