How to Test Klixon Sensata 4CR Series Motor Start Relays
, by Daniel Rehe, 1 min reading time
How to Test Klixon Sensata 4CR Series Motor Start Relays
How to Test Klixon Sensata 4CR Series Motor Start Relays
4CR Single Circuit Relay
For single circuit relay, apply pick-up current through terminal #3 and #4, then check if the circuit between terminal #2 and #4 is close, then remove current, check if the circuit between terminal #2 and #4 is open.
4CR Two Circuit Relay
For two circuit relay, apply pick-up current through terminal #3 and #1, then check if the circuit between terminal #2 and #4 is close, then remove current, check if the circuit between terminal #2 and #4 is open.
Note: 4CR relay can only be used for AC motors, it can’t be used for DC.