How to Test Klixon Sensata 4CR Series Motor Start Relays
How to Test Klixon Sensata 4CR Series Motor Start Relays
4CR Single Circuit Relay
For single circuit relay, apply pick-up current through terminal #3 and #4, then check if the circuit between terminal #2 and #4 is close, then remove current, check if the circuit between terminal #2 and #4 is open.
4CR Two Circuit Relay
For two circuit relay, apply pick-up current through terminal #3 and #1, then check if the circuit between terminal #2 and #4 is close, then remove current, check if the circuit between terminal #2 and #4 is open.
Note: 4CR relay can only be used for AC motors, it can’t be used for DC.
For 4CR Catalogue Download Here.
For additional support please contact Fastron Support.