add wishlist add wishlist show wishlist add compare add compare show compare preloader
  • electro-marker-icon Store Location
  • Currencies
    • AUD
    L/A

Oztherm Phase Angle Controller Special (SP) Builds

 

F311 Series Single Phase, Phase Angle Controller 

Fastron - Oztherm Special (SP) Number
Description of Special Feature
Reccommended Application
F311-1-25DC-C-F-SP04
Half Controller Bridge with Flywheel Diode
Voltage Controller with POT Input
F311-4-40DC-F-MV-SP05
370VDC Half Controlled Bridge with, Flywheel Diode, Suppression and Overvoltage Varistor
0-370VDC Power Supply
F311-4-N/A-SP06
Current Trip Relay NC
F311-4-750W-C-F
F11-4-N/A-C Mounted on Gear Tray C/W 1M Gate Leads, Supplied Loose with Square Body Fuse and 750/5 CT
F311-4-N/A-C-SP08
Zero Ramp (C15 Removed), Mounted on Aluminium Gear Tray 260x180x3mm, 500mm Gate Leads 250/5 Amo Ct Supplied Loose, Input 0-10V
F311-2-25DC-F-CI-SP09
Controller Rectifier, Internal CT
F311-480-65-CI-F-SP10
Internal Fuse, Mounted 10K POT and 0-100% Escutcheon on Cover with knob, 4M 4 Core + Earth Cable Supplied1.35PVC/PVC Orange Circular 10MM Loose
F311-48-25-CI-SP11
GBPC3510 Mounted on Heatsink for DC output, Internal CT
20V,15 Amp Power Supply
F311-220-25-CI-SP11
GBPC3510 Mounted on Heatsink for DC output, Internal CT
F311-2-25-CCE-F-SP11A
Current Control, Supplied with HAS 50-S
F311-2-100-CI-F-T-SP12
Current Trip Time Constant = 220mS, Soft Start, 3 - 75 Second Ramp up Ramp Down.
Soft Starter
F311-4-300F-C-F
Gear Tray Mounted COntroller + ST6157, 0-10K POT & 4-20mA switchable inputs, Loose CT, POT to 4-20mA Converter
F311-SP15
0-1V output from MI terminals, 0-1V Control Input, MI connected to DCL33AA/M as converter.
F311-480-40-CC-F-SP16
Constant Current for Inductive Load, Blocking Diode
F311-4-25-CI-F-SP17
5-10 second ramp setting range, Control input set to 0-100% permanently, Gain POT still functional to allow phasing back a fixed amount.
F311-2-22-A-F-PW-MP-SP18
Set to 22 Amp Full Scale, internal Fuse, MP set to maximum level to suit Signal Conditioner, Set to constant power source with voltage limit and current trip.
Bag Sealing Element Control
F311-2-8-A-F-PW-MP-SP19
Set to 8 Amp Ful Scale, internal Fuse, MP set to maximum level to suit Signal Conditioner, Set to constant power source with voltage limit and current trip.
Bag Sealing Element Control
F311-4-N/A-SP20
Use as Half Wave Rectifier, 10K Control Input
DC Power Supply
F311-4-N/A-SP21
Constant Current, Constant Voltage
Chlorinator
F311-2-60--N/A-C-SP22
60hz with Current Limit delay
F311-2-N/A-C-SP23
Current Limt Delay, Check Flashing at turn on
F311-140-100-F-SP24
140V Transformer, Internal Fuse
F311-4-50-C-MI-F-SP25 0-1V MI output for DCL 0-1V to 4-20mA converter mode
F311-4-180F-CI-F-T-SP028 SP=No ramp
F311-4-300F-CI-F-T-SP029 SP=No ramp
F311-4-100F-SP30 DC controlled bridge with Freewheel diode, 5V I/P, no ramp & special cover/connectors
F311-4-N/A-C-MI-T-SP031 400mm Gate leads soldered to board, mounted on aluminium plate and CT 132 D5 75/5 CT's supplied loose
F311-380-N/A-CE-SP32 Control Card only same as S/N 9807 3678 Page 117. Card set up for 0-12VDC input into into PCB from a HTA100S. 12V = 300ADC. (1.5kohm in parallel with 390ohms.) 
F311-4-200F-C-F-SP33 SP=No ramp supplied with loose fuses to suit 200F
F311-2-N/A-CC-SP034 Modified to suit customer requirements
F311-4-350F-C-F-SP35 uses 1 x H31/250MA with 1 x TT285N14TOF fan cooled, using standard side plates and covers. loose 400/5 CT and 350BBF fuse kit.  Foam Wire Cutter
F311-4-N/A-C-T-SP36 Card built onto 180 x 260mm aluminium gear plate; 1m gate leads, Zero start/stop RAMP  
F311-4-100-CI-F-SP037 Fuse Mounted internally like the CI option.
F311-4-N/A-C-SP38
F311-4-N/A-CC-T-SP39  As per the SP36 with 0-10VDC external current limit input and lowest current limit delay possible.
F311-4-N/A-SP040 PCB replacement for original F311-4-N/A-SP001 (Green Book) Remove C15. Set ramp to Minimum. Ramp Pot fully anti-clockwise. No cables.  Spot Welder
F311-4-N/A-SP041 Card only. Same as SP008 without gear plate, gate leads or CT. 
F311-4-75-C-FI-SP42 Half Wave Output Control, Internal Fuse Vibration Machine

 

F312 Series Single Phase, Phase Angle Control Module for SSR's

Fastron - Oztherm Special (SP) Number

Description of Special Feature

Reccommended Application

F312-60-VP-SP02 60V Transformer, CI with External 10K POT
F312-2-VA-SP03 with DRA1-CX480D5R
F312-2-VP-SP04 45 Second Ramp Up, 10K Resistor built in, Votl Free Contact to Enable/Disable Controller
F312-2-VP-SP05 Additional External Span Laboratory, Incubators
F312-4-VP-SP05 Additional External Span Laboratory, Incubators

 

F330 Series 3 Phase, Phase Angle Controller 

Fastron - Oztherm Special (SP) Number

Description of Special Feature

Reccommended Application

 

F430 Series 2 Leg, Burst Fire Controller 

Fastron - Oztherm Special (SP) Number

Description of Special Feature

Reccommended Application

 

F431 Series 3 Phase, Burst Fire Controller 

Fastron - Oztherm Special (SP) Number

Description of Special Feature

Reccommended Application

 

F920 Series AC/DC Current Transducer with Process Output

Fastron - Oztherm Special (SP) Number

Description of Special Feature

Reccommended Application

 

Light