Current Transformer Type
|
Advantages
|
Image
|
Available Range
|
Northern Design XD Series, 4-20mA, 0-5V, or Pulse Output |
Solid Core, True and Average RMS Types, Din Rail Mount, User Selectable Range |
 |
100 mAmp - 300 Amp (User Selectable) |
LEM AT Series, 0-5V, 4-20mA, 0-10V |
Split Core, 1.5% Accuracy, Average RMS, Low Cost |
 |
5 Amp- 150 Amp |
LEM ATO Series, 4-20mA |
Split Core, 1.5% Accuracy, Average RMS, Low Cost, with flying leads |
 |
0 Amp - 5 Amp |
LEM AK Series, 0-10V, 0-5V, 0-20mA, 4-20mA |
Accuracy to 1%, User Selectable Range, Average RMS, Solid and Split Core Types |
 |
2 Amp - 200 Amp (User Selectable) |
LEM AKR Series, 0-10V, 0-5V, 0-20mA, 4-20mA |
Accuracy to 1%, User Selectable Range, True RMS, Solid and Split Core Types
|
 |
1 Amp - 7500 Amp |
LEM AP Series, 0-10V, 0-5V, 4-20mA
|
Accuracy to 1%, User Selectable Range, Average RMS, Split Core
|
 |
10 Amp - 400 Amp |
LEM APR Series, 0-10V, 0-5V, 4-20mA |
Accuracy to 1%, User Selectable Range, True RMS, Split Core
|
 |
10 Amp - 400 Amp |
LEM AHR Series, 0-10V, 0-5V, 4-20mA
|
Accuracy to 1%, Large Busbar Mount, True RMS, Railway Approved
|
 |
500Amp - 2000Amp |
LEM DHR Series, 0-10V, 0-5V, 4-20mA |
AC and DC Measurement, True RMS, Railway Approved |
 |
100 Amp - 1000 Amp |
Fastron DCBT Series +/-10V, 4-20mA Bipolar |
DC Measurement Only, Accuracy 1%, Solid Core |
|
50 Amp - 300 Amp |
LEM DK Series, 0-10V, 0-5V, 0-20mA, 4-20mA, 4-20mA Bipolar
|
DC Measurement Only, Accuracy 1%, Solid or Split Core Types |
 |
5A mp - 2000 Amp |
LEM HAZ Series, 0-10V, 0-5V, 0-20mA, 4-20mA, 4-20mA Bipolar |
Accuracy to 1%, Busbar Mount, Average or True RMS Types available |
 |
5Amp - 2000Amp |
Fastron FRC Series, 0-10V |
Accuracy to 2%, Average RMS, Low Cost, Easy to install
|
 |
100Amp - 800 Amp |
Fastron FES Series, 4-20mA |
Accuracy to 5% True RMS, Easy to install, Low Cost
|
 |
500Amp - 5000Amp (User Selectable) |
LEM DVL Voltage Series, 4-20mA |
Accuracy to 0.5%, 8.5kV Isolation, Railway Approved, Instantaneous Output |
 |
50 Volt - 1500 Volt |
LEM DVM Voltage Series, 4-20mA |
Accuracy to 0.5%, 12kV Isolation, Railway Approved, Instantaneous Output
|
 |
50 Volt - 2000 Volt |
Magnelab DVT Series, 4-20mA, 0-10V |
Accuracy +/-1%, 4-20mA output, DIN Rail Mount, 150% Continuous Overload, 4.5kV Isolation, Instantaneous Output (10ms) |
 |
10-1000VDC |
LEM ART Series Rogowski Coil & AI-PMUL Integrator - Ferrite Core, 0.333v, 0.166v, 4-20mA, 0-20mA, 0-5V, 0-10V |
Highest Accuracy to Class 0.5, Easy to install, Integrator suits and LEM Coil, Low interference, True RMS or Instantaneous Output
|
 |
100 - 5000 Amp (User Selectable)
|