{"product_id":"thyro-a-1a-230-60-h3","title":"Thyro-A-1A-230-60-H3, Thyro-A-1A-Series Single Phase SCR Controller 60Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_60 Amp","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eThyro-A-1A-230-60-H3, Thyro-A-1A-Series Single Phase SCR Controller 60Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_60 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet, Profibus, Ethernet, Modbus Comms\u003c\/li\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control, +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-230-60-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control, +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476916768902,"sku":"FE-Thyro A 1A 230-60 H3","price":1015.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_134cdf19-8c01-43cd-97d7-1b21db82deca.jpg?v=1759459727","url":"https:\/\/fastron.com.au\/products\/thyro-a-1a-230-60-h3","provider":"Fastron Electronics Store ","version":"1.0","type":"link"}