{"product_id":"frs4-c40-385v-1p-1-0-r","title":"FRS4-C40 385V 1P (1+0) (R), Class II\/Type 2, AC Surge Protection Device (SPD), Un = 320VAC, Uc = 385VAC, 1 Pole In = 20\/50kA L-N, L\/N-PE, DIN Rail Mount, High Energy MOV Type, with Remote Contacts","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eTrent FRS4-C40 385V 1P (1+0) (R), Class II\/Type 2, AC Surge Protection Device (SPD), Un = 320VAC, Uc = 385VAC, 1 Pole In = 20\/50kA L-N, L\/N-PE, DIN Rail Mount, High Energy MOV Type, with Remote Contacts\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 89.3762%; height: 274.313px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003eFRS4-C40 385V 1P (1+0) (R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eNominal Voltage (Un)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003e320VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.387%;\"\u003e\u003cstrong\u003eMaximum Operating Voltage (Uc(\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%;\"\u003e\u003cspan\u003e385VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.387%;\"\u003e\u003cstrong\u003eVoltage Protection Level (Up)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%;\"\u003e\u003cspan\u003e\u0026lt;1.5kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003e\u003cspan\u003eClass II \/ Type 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003e\u003cspan\u003eSub Distribution Boards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003e\u003cspan\u003eL\/N-PE,  High Energy MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 39.1875px;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 39.1875px;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 39.1875px;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 39.1875px;\"\u003e\u003cspan\u003eImax up to 40kA(8\/20us) L\/N-PE 385VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 39.1875px;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 39.1875px;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1780616331\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS4-C40-385R-T2_WEB.pdf\" target=\"_blank\" title=\"FRS4-C40 1P 320VAC Datasheet\" rel=\"noopener\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":44034406285446,"sku":"FE-FRS4-C40 385V 1P (1+0) (R)","price":39.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS4-C40-385R-T2.jpg?v=1780615714","url":"https:\/\/fastron.com.au\/products\/frs4-c40-385v-1p-1-0-r","provider":"Fastron Electronics Store ","version":"1.0","type":"link"}