{"product_id":"frs2-c40-320-r-2-0","title":"FRS2-C40\/320\/R 2+0, 2 Pole (L\/N,PE) Un = 230VAC Type 2 (Class II) Surge Protection Device, 20\/40kA, Pluggable, With Remote C\/O Contacts. Uc = 320VAC","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFRS2-C40\/320\/R 2+0, 2 Pole (L\/N,PE) Un = 230VAC Type 2 (Class II) Surge Protection Device, 20\/40kA, Pluggable, With Remote C\/O Contacts. Uc = 320VAC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\" style=\"height: 293.907px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5938px;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5938px;\"\u003eFRS2-C40\/320\/R 2+0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5938px;\"\u003e\u003cstrong\u003eNominal Voltage (Un)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5938px;\"\u003e230VAC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5938px;\"\u003e\u003cspan\u003e320VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eVoltage Protection Level (Up)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e\u0026lt;1.5kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5938px;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5938px;\"\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5938px;\"\u003eType 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5938px;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5938px;\"\u003e\u003cspan\u003eSub Distribution Board or Machinery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5938px;\"\u003e\u003cspan\u003eL\/N,PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5938px;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5938px;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5938px;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5938px;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5938px;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 39.1875px;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 39.1875px;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5938px;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5938px;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5938px;\"\u003e\u003cspan\u003e400g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5938px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5938px;\"\u003e\u003cspan\u003eIEC614643-31:2018 (TUV, CE Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1765345981\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS2-C40_Un_500VDC_Uc_600VDC.pdf\" title=\"Trent FRS2-C40 500VDC Surge Protection Device Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Trent FRS2-C40 275VAC 320VAC Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1768974010\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS2-C40_275VAC_320VAC.pdf\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" title=\"Raycap G29 SPD Tester\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":43066849919110,"sku":"FE-FRS2-C40\/320\/R 2+0","price":53.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS2-C40-275R-T2.jpg?v=1768973658","url":"https:\/\/fastron.com.au\/products\/frs2-c40-320-r-2-0","provider":"Fastron Electronics Store ","version":"1.0","type":"link"}