{"product_id":"fdv-300-v05-24","title":"FDV-300-V05-24, DC Voltage Transducer, Din Rail Mount, 0-300VDC, 0-5V output, 24VDC Supply Voltage, 150mS Response","description":"\u003ch1\u003e\u003cspan style=\"color: #8ab3d9;\"\u003e\u003cstrong\u003eFastron FDV-300-V05-24, DC Voltage Transducer, Din Rail Mount, 0-300VDC, 0-5V output, 24VDC Supply Voltage, 150mS Response\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e150mS Response Time\u003c\/li\u003e\n\u003cli\u003ePC 94 UL V0\u003c\/li\u003e\n\u003cli\u003eInput signals can be converted to insulated 5V DC output (for voltage output type)\u003c\/li\u003e\n\u003cli\u003eEach unit needs just 22.5 x 114\u003cspan\u003e \u003c\/span\u003emm depth DIN Rail\u003cspan\u003e \u003c\/span\u003ecabinet space\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 100.061%;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 59.7804%;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFastron Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40.086%;\"\u003eFDV-300-V05-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 59.7804%;\"\u003e\u003cstrong\u003eAnalogue Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40.086%;\"\u003e0-5V\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 59.7804%;\"\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40.086%;\"\u003e0 - 300VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 59.7804%;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40.086%;\"\u003e120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 59.7804%;\"\u003e\u003cstrong\u003eOverload\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40.086%;\"\u003e\u003cspan\u003e150% Continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 59.7804%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40.086%;\"\u003e-30 - 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 59.7804%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40.086%;\"\u003e24VDC +\/-15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 59.7804%;\"\u003e\u003cstrong\u003eVoltage Isolation (1 min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40.086%;\"\u003e2.5kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 59.7804%;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40.086%;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 59.7804%;\"\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40.086%;\"\u003e150mS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 59.7804%;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40.086%;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 59.7804%;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMounting Style \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40.086%;\"\u003eDIN Rail Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 59.7804%;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40.086%;\"\u003eCE, UL94V0\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 59.7804%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40.086%;\"\u003e170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 59.7804%;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 40.086%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1617856706\/Fastron%20Stuff\/Transducers-New\/Fastron-FDV_DC_Voltage_Transducer.pdf\" title=\"Fastron FDV Series Datasheet\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fastron Electronics","offers":[{"title":"Default Title","offer_id":39768948244614,"sku":"FE-FDV-300-V05-24","price":265.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FDV-500-420-24_Angle_3_51d4385a-30ba-4646-bb1e-b8f7866ebfad.png?v=1686899263","url":"https:\/\/fastron.com.au\/products\/fdv-300-v05-24","provider":"Fastron Electronics Store ","version":"1.0","type":"link"}