{"title":"Voltage Monitoring Relays","description":"\u003ch1\u003e\u003cspan style=\"color: #77b4de;\"\u003e\u003cstrong\u003eVoltage Monitoring Relays\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAre you looking for Voltage monitoring relays to suit your control application? Here at Fastron Electronics, we provide several types of monitoring relays from Crouzet Automation, Fastron OEM, and Iskra Systemi to meet your needs.\u003c\/p\u003e\n\u003cp\u003eVoltage monitoring relays respond to abnormal or pre-programmed conditions. Typically, they operate when phase supply is lost or when there has been a sequence reversal. As leaders in automation and control, Crouzet have provided their solutions across a range of industries – from Aerospace to Defence, Electrical to Access Control.\u003c\/p\u003e\n\u003cp\u003eWe are confident that these products can meet your voltage monitoring relay needs.\u003c\/p\u003e\n\u003cp\u003eFastron Electronics stocks only a limited range of monitoring relays based on market demand. If you are interested in any other monitoring relay products, please contact us today. We will provide availability and pricing information for any product not currently in stock.\u003c\/p\u003e\n\u003cp\u003eAlternatively, shop online today for the products on this page and enjoy free shipping on all purchases over $300AUD.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Contact Fastron\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/pages\/contact-us\" target=\"_blank\"\u003eContact us\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e for any specific enquiries\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"84873220","title":"84873220 3 Phase C-Lynx Voltage Monitoring Relay With DPDT Contacts, 3 x 220 - 480 V AC H3US, Sequence, Failure, Imbalance, Under\/Over","description":"\u003ch1\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eCrouzet 84873220 3 Phase C-Lynx Voltage Monitoring Relay With DPDT Contacts, 3 x 220 - 480 V AC H3US, Sequence, Failure, Imbalance, Under\/Over, Neutral Loss\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eH3US and M3US relays control, on 3-phase networ\u003c\/strong\u003eks :\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOvervoltage between phases,\u003c\/li\u003e\n\u003cli\u003eUndervoltage between phases\u003c\/li\u003e\n\u003cli\u003eThe H3USN relay controls, on 3-phase networks :\u003c\/li\u003e\n\u003cli\u003eOvervoltage between phases and neutral,\u003c\/li\u003e\n\u003cli\u003eUndervoltage between phases and neutral\u003c\/li\u003e\n\u003cli\u003eAsymmetry (Imbalance)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLoss of neutral\u003c\/li\u003e\n\u003cli\u003eMulti-voltage Products\u003c\/li\u003e\n\u003cli\u003eControls its own supply voltage\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement\u003c\/li\u003e\n\u003cli\u003eLED status indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e3-phase voltage controllers which monitor : \u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eUndervoltage, adjustable from -20 to -2 % of Un\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAsymmetry adjustabel from 5 to 25%\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOvervoltage, adjustable from 2 to 20 % of Un \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePresence of the neutral (H3USN only) Measurements are taken between Phases for the H3US \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eM3US and between Phases and Neutral for the H3USN Faults are signalled via LEDs, distinguishing the origin of the fault (one LED for the upper threshold, one LED for the lower threshold). Set the selector switch to the 3-phase network voltage Un. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe position of this selector switch is only taken into account when the unit is powered up. If the switch position changes while the unit is operating, all the LEDs flash but the product continues to work normally with the voltage selected on energisation prior to the change of position. The LEDs return to their normal state if the switch is reset to its initial position defined before the last energisation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e84873220 (3 Phase C-Lynx Voltage Monitoring Relay With DPDT Contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUndervoltage\/Overvoltage between phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 x 220 → 3 x 480 V ∿\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x C\/O Relays, 250VAC\/DC @ 5 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMin Breaking Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10mA\/5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTiming Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 \u003cspan\u003e→ 30s (0, +10%)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eDelay on Pickup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAlarm Delay on Time (max)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eReset Time \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eFixed Hysteresis\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2% of Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMaximum Measurement Cycle Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e150ms\/True RMS Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMeasurement Accuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSame as Measurement \u003cspan\u003e3 x 220 → 3 x 480 V ∿\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, GL, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOver Voltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in accordance with IEC\/EN 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in accordance with IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (Front), IP20 (Rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMechanical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunity to vibrations IEC\/EN 60068-2-6, test Fc\u003c\/p\u003e\n\u003cp\u003eImmunity to shock IEC\/EN 60068-2-27, test Ea\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff;\" title=\"Crouzet Automation 84873220 Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552807531\/Crouzet%20Automation\/Datasheets\/H3US.pdf\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003ctable style=\"width: 29.4011%; float: left;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 10%; text-align: right;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%; text-align: right;\"\u003e\u003cstrong\u003eLegend\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eOvervoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eHysteresis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eUndervoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003ePhases L1, L2, L3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e5\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eRelay R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eRelay R2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eOvervoltage threshold delay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eUndervoltage threshold delay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align: right;\"\u003e \u003c\/p\u003e\n\u003cdiv style=\"text-align: right;\" class=\"panel-heading\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: right;\" class=\"panel-body\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: right;\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"166\" width=\"312\" alt=\"84873220 Application Note\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/CO_RMC2_H3US_N_N1_large.jpg?v=1560665492\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe relay monitors its own supply voltage. It controls :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eUndervoltage, adjustable from - 2 to - 20 % of Un (-2 to -12 % over the 3 x 220 V ∿ range due to the minimum voltage 194 V ∿)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOvervoltage, adjustable from + 2 to +20 % (+2 to +10 % over the 3 x 480 V ∿ range due to the maximum voltage 528 V ∿). Each threshold has its own time delay with independent setting between 0.3 and 30 s. In the event of a voltage fault, the corresponding relay (one undervoltage output\/one overvoltage output) opens at the end of the time delay set by the user. In the event of phase failure, both relays open instantaneously, without waiting for the end of the time delay. The two relay LEDs go out. The relay monitors its own supply voltage. It controls : \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePresence of the neutral, - Undervoltage, adjustable from -2 to -20 % of Un, - Overvoltage, adjustable from +2 to +20 %. Each threshold has its own time delay with independent setting between 0.3 and 30 s. In the event of a voltage fault, the corresponding relay (one undervoltage output\/one overvoltage output) opens at the end of the time delay set by the user. If neutral is lost, both relays open instantaneously and the corresponding LED is extinguished, without waiting for the end of the time delay. The two relay LEDs are extinguished.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Crouzet Automation","offers":[{"title":"Default Title","offer_id":18422767550579,"sku":"FE-84873220","price":316.97,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/PH_RMC2_HUH_fc8e8a83-b5c6-4166-a737-43ae5977526e.jpg?v=1679271789"},{"product_id":"84872130","title":"84872130, Single Phase Multi-Function Voltage Control Relay Under\/Overvoltage Detection with Latching(Memory) Function - 35 mm HUH, 15-600 VAC\/DC Measurement, 24\/240 VAC\/DC Supply","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Automation 84872130, Single Phase Multi-Function Voltage Control Relay Under\/Overvoltage Detection with Latching(Memory) Function - 35 mm HUH, 15-600 VAC\/DC Measurement, 24\/240 VAC\/DC Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eFor under and overvoltage monitoring of Single phase AC or DC Voltages up to 600V\u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #7bb1de;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eControl of AC and DC voltages\u003c\/li\u003e\n\u003cli\u003eAutomatic recognition of AC\/DC\u003c\/li\u003e\n\u003cli\u003eMeasurement ranges from 15 V to 600 V\u003c\/li\u003e\n\u003cli\u003eChoice between under and overvoltage\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement\u003c\/li\u003e\n\u003cli\u003eSelectable latching (memory) function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e84872130 (Single Phase C-Lynx Voltage Monitoring Relay With DPDT Contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUndervoltage\/Overvoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x 15 - 600 VAC\/DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x C\/O Relays, 250VAC\/DC @ 8 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMin Breaking Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10mA\/5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDelay on Threshhold Crossing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 \u003cspan\u003e→ 3s (0, +10%)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eDelay on Pickup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAlarm Delay on Time (max)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eReset Time \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAdjustable Hysteresis\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5 - 50% of Threshhold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMaximum Measurement Cycle Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e30ms\/True RMS Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMeasurement Accuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSame as Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, GL, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOver Voltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in accordance with IEC\/EN 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in accordance with IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (Front), IP20 (Rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMechanical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunity to vibrations IEC\/EN 60068-2-6, test Fc\u003c\/p\u003e\n\u003cp\u003eImmunity to shock IEC\/EN 60068-2-27, test Ea\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1551074384\/Crouzet%20Automation\/Datasheets\/84872130_-_HUH.pdf\" title=\"Crouzet Automation 84873130 Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1759708988\/Crouzet%20Automation\/Datasheets\/EL_MR_VC_HUL-EUL-HUH-EUH_Datasheet_EN.pdf\" title=\"Crouzet HU series Single Phase Voltage Monitoring Relays\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eRange Overview HU Series\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Crouzet Automation","offers":[{"title":"Default Title","offer_id":29549823230067,"sku":"FE-84872130","price":278.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/PH_RMC2_HUH_3c7f3f34-ab60-439e-a90f-f40b096ff657.jpg?v=1679271858"},{"product_id":"frv8-04-460","title":"FRV 8-04\/460, 220-460VAC L-L Voltage Monitoring Relay, 3 Phase Over\/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Adjustable Timer Delay, Adjustable Upper and Lower Voltage Limits","description":"\u003ch1\u003e\u003cspan style=\"color: #7aa4d6;\"\u003e\u003cstrong\u003eFastron FRV 8-04\/460, 220-460VAC L-L Voltage Monitoring Relay, 3 Phase Over\/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Adjustable Timer Delay, Adjustable Upper and Lower Voltage Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eFRV 8 Series serves to monitor voltage, phase failure and sequence in switchboards, protection of devices in 3-phase mains\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #7ca6d9;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUpper and lower level of monitoring voltage\u003c\/li\u003e\n\u003cli\u003eAdjustable time delay eliminates short voltage peaks and failures in     the main\u003c\/li\u003e\n\u003cli\u003eSupply is done from monitored voltage\u003c\/li\u003e\n\u003cli\u003eFaulty state is indicated by red LED and by opening of output relay     contact\u003c\/li\u003e\n\u003cli\u003eOutput contact  1 x Changeover \/ SPDT 10 A \/250 V AC1\u003c\/li\u003e\n\u003cli\u003eIn case supply voltage falls below  60 %Un (U lower level) relay \u003csub\u003eoff \u003c\/sub\u003e    immediately opens without delay\u003c\/li\u003e\n\u003cli\u003eFRV 8-04\/460 - supply from all phases which means that relay is functional also in case when one phase is faulty\u003c\/li\u003e\n\u003cli\u003eVariant \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"FRV%208-04-265\" title=\"FRV 8-04\/265 Page\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eFRV 8-04\/265\u003c\/a\u003e\u003c\/span\u003e - supply  L1-N, means that relay monitors also failure of neutral wire\u003c\/li\u003e\n\u003cli\u003e1-MODULE, DIN rail mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eFRV 8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSupply and measuring\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eL1, L2, L3 (220,230,240,380,400,415,440,460VAC)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSupply terminals\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eL1, L2, L3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSupply\/measured voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e3 x 220-460 V \/ 50 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eLevel U\u003csub\u003emax\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e105 - 125 % U\u003csub\u003en\u003c\/sub\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eLevel U\u003csub\u003emin\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e75 - 95 % U\u003csub\u003en\u003c\/sub\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eBurden\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003emax. 2 VA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eHysteresis\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e2 %\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #80abdf;\"\u003e\u003cstrong\u003eMax. permanent overload\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eAC 3 x 460 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePeak overload \u0026lt;1ms\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eAC 3 x 500 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTime delay T1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003emax. 500 ms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTime delay T2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eadjustable 0.1-10 s\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #80aade;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of contacts\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e1 x changeover\/ SPDT (AgNi \/ Silver Alloy)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e10 A \/ AC1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eBreaking capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e2500 VA \/ AC1, 240 W \/ DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e10 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSwitching voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e250 V AC1 \/ 24 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMin. breaking capacity DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e500 mW\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eIndication of state\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003ered LED\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #80abdf;\"\u003e\u003cstrong\u003eMechanical life\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e1 x 10\u003csup\u003e7\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical life (AC1)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e1 x 10\u003csup\u003e5\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOther information\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e-20 ... +55 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e-30 ... +70 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical strength\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e4 kV (supply - output)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating position\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eany\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eDIN rail EN 60715\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eProtection degree\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eIP 40 from front panel \/ IP 10 terminals\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOvervoltage cathegory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eIII.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMax. cable size (mm )\u003csup\u003e2\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003esolid wire max. 2x2.5 or 1x4  ;  with sleeve max. 1x2.5 or 2x1.5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e90 x 17,6 x 64 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e69 g\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eEN 60255-6, EN 61010-1, RoHS, CE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584407807\/Fastron%20Stuff\/Relays\/FRV_Voltage_Monitoring_Relay_3_Phase.pdf\" target=\"_blank\" title=\"Fastron FRV Datasheet\" rel=\"noopener noreferrer\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584407817\/Fastron%20Stuff\/Relays\/Fastron_Time_Relays_-_Full_Catalogue_WEB_version.pdf\" title=\"Fastron Monitoring Relays Catalogue\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eFastron Monitoring\/Time Relays Catalogue\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan style=\"color: #000000;\"\u003e For items in our catalogue which are not listed online please \u003c\/span\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/pages\/contact-us\" title=\"Contact Fastron\"\u003eContact Us for Possible Replacement\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003eRelay in 3-phase main monitors size of phase voltage.  It is possible to set two independent voltage levels and thus it is possible to set two independent voltage levels and monitor e.g. undervoltage and overvoltage independently. In normal state when voltage is within set levels, output relay is closed and red LED shines.\u003c\/p\u003e\n\u003cp\u003eIn case  voltage exceeds or falls below the set levels, output relay opens and red LED shines ( LED indicates faulty state – flashes when timing). In case supply voltage falls below 60 % Un (U\u003csub\u003eOFF\u003c\/sub\u003e lower level)relay immediately opens without delay and faulty state is indicated by red LED.In case timing is in progress and faulty state is indicated, timing is immediately stopped.\u003c\/p\u003e","brand":"Fastron Electronics","offers":[{"title":"Default Title","offer_id":31408332865670,"sku":"FE-FRV 8-04\/460","price":65.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FRV8-04_side_Angle460V.png?v=1659332215"},{"product_id":"mvr-54n-400vac","title":"MVR 54N 400VAC, Voltage Monitoring Relay, 3 Phase 4 wire, 415VAC Over\/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Adjustable Timer Delay, Adjutsable Upper and Lower Voltage Limits","description":"\u003ch1\u003e\u003cspan style=\"color: #7aa4d6;\"\u003e\u003cstrong\u003eIskra Doo MVR 54N 400VAC Series Voltage Monitoring Relay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eMVR 54N Series serves to monitor voltage, phase failure and sequence in     switchboards, protection of devices in 3-phase 4 wire mains\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #7ca6d9;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUpper and lower level of monitoring voltage\u003c\/li\u003e\n\u003cli\u003eAdjustable time delay eliminates short voltage peaks and failures in the main\u003c\/li\u003e\n\u003cli\u003eSupply is done from monitored voltage\u003c\/li\u003e\n\u003cli\u003eFaulty state is indicated by red LED and by opening of output relay contact\u003c\/li\u003e\n\u003cli\u003eOutput contact  1 x Changeover \/ SPDT 8 A \/250 V AC1\u003c\/li\u003e\n\u003cli\u003eIn case supply voltage falls below  60 %Un (U lower level) relay \u003csub\u003eoff \u003c\/sub\u003e    immediately opens without delay\u003c\/li\u003e\n\u003cli\u003eMVR 54 - supply from all phases which means that relay is functional also in case when one phase is faulty\u003c\/li\u003e\n\u003cli\u003eVariant MVR 54N - supply  L1-N, means that relay monitors also failure of neutral wire\u003c\/li\u003e\n\u003cli\u003e1-MODULE, DIN rail mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable width=\"717\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"214\"\u003e\n\u003cp\u003eMVR 54\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"215\"\u003e\n\u003cp\u003eMVR 54N\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eSupply and measuring\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"214\"\u003e\n\u003cp\u003eL1, L2, L3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"215\"\u003e\n\u003cp\u003eL1, L2, L3, N\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eSupply terminals\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"214\"\u003e\n\u003cp\u003eL1, L2, L3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"215\"\u003e\n\u003cp\u003eL1, N\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eSupply\/measured voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"214\"\u003e\n\u003cp\u003e3 x 400 V \/ 50 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"215\"\u003e\n\u003cp\u003e3 x 400 V \/ 230 V \/50 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eLevel U\u003csub\u003emax\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003e105 - 125 % U\u003csub\u003en\u003c\/sub\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eLevel U\u003csub\u003emin\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003e75 - 95 % U\u003csub\u003en\u003c\/sub\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eBurden\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003emax. 2 VA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eHysteresis\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003e2 %\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #80abdf;\"\u003e\u003cstrong\u003eMax. permanent overload\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"214\"\u003e\n\u003cp\u003eAC 3 x 460 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"215\"\u003e\n\u003cp\u003eAC 3 x 265 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003ePeak overload \u0026lt;1ms\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"214\"\u003e\n\u003cp\u003eAC 3 x 500 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"215\"\u003e\n\u003cp\u003eAC 3 x 288 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eTime delay T1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003emax. 500 ms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eTime delay T2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003eadjustable 0.1-10 s\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #80aade;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of contacts\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003e1x changeover\/ SPDT (AgNi \/ Silver Alloy)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003e8 A \/ AC1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eBreaking capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003e2500 VA \/ AC1, 240 W \/ DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003e10 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eSwitching voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003e250 V AC1 \/ 24 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eMin. breaking capacity DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003e500 mW\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eIndication of state\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003ered LED\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #80abdf;\"\u003e\u003cstrong\u003eMechanical life\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003e1 x 10\u003csup\u003e7\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical life (AC1)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003e1 x 10\u003csup\u003e5\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eOther information\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003e-20 ... +55 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003e-30 ... +70 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical strength\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003e4 kV (supply - output)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating position\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003eany\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003eDIN rail EN 60715\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eProtection degree\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003eIP 40 from front panel \/ IP 10 terminals\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eOvervoltage cathegory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003eIII.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eMax. cable size (mm )\u003csup\u003e2\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003esolid wire max. 2x2.5 or 1x4  ;  with sleeve max. 1x2.5 or 2x1.5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003e90 x 17,6 x 64 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"214\"\u003e\n\u003cp\u003e69 g\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"215\"\u003e\n\u003cp\u003e67 g\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"288\"\u003e\n\u003cp\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"429\"\u003e\n\u003cp\u003eEN 60255-6, EN 61010-1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567488098\/Iskra%20Systemi\/Datasheets\/Catalogue_MVR_54_MVR_54N_1.pdf\" title=\"Iskra MVR Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003eRelay in 3-phase main monitors size of phase voltage.  It is possible to set two independent voltage levels and thus it is possible to set two independent voltage levels and monitor e.g. undervoltage and overvoltage independently. In normal state when voltage is within set levels, output relay is closed and red LED shines.\u003c\/p\u003e\n\u003cp\u003eIn case  voltage exceeds or falls below the set levels, output relay opens and red LED shines ( LED indicates faulty state – flashes when timing). In case supply voltage falls below 60 % Un (U\u003csub\u003eOFF\u003c\/sub\u003e lower level)relay immediately opens without delay and faulty state is indicated by red LED.In case timing is in progress and faulty state is indicated, timing is immediately stopped.\u003c\/p\u003e","brand":"Iskra Doo","offers":[{"title":"Default Title","offer_id":31453345841286,"sku":"FE-MVR 54 N 400VAC","price":95.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/MVR54400V.png?v=1679275786"},{"product_id":"frv-8-04-265","title":"FRV 8-04\/265, 127 to 265VAC L-N Voltage Monitoring Relay, 3 Phase 4 Wire Over\/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Adjustable Timer Delay, Adjustable Upper and Lower Voltage Limits","description":"\u003ch1\u003e\u003cspan style=\"color: #7aa4d6;\"\u003e\u003cstrong\u003eFastron FRV 8-04\/265, 127 to 265VAC L-N Voltage Monitoring Relay, 3 Phase 4 Wire Over\/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Adjustable Timer Delay, Adjustable Upper and Lower Voltage Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eFRV 8 Series serves to monitor voltage, phase failure and sequence in     switchboards, protection of devices in 3-phase 4 wire mains\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #7ca6d9;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUpper and lower level of monitoring voltage\u003c\/li\u003e\n\u003cli\u003eAdjustable time delay eliminates short voltage peaks and failures in     the main\u003c\/li\u003e\n\u003cli\u003eSupply is done from monitored voltage\u003c\/li\u003e\n\u003cli\u003eFaulty state is indicated by red LED and by opening of output relay     contact\u003c\/li\u003e\n\u003cli\u003eOutput contact  1 x Changeover \/ SPDT 10 A \/250 V AC1\u003c\/li\u003e\n\u003cli\u003eIn case supply voltage falls below  60 %Un (U lower level) relay \u003csub\u003eoff \u003c\/sub\u003e    immediately opens without delay\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"frv8-04-460\" title=\"FRV8-04\/460 Page\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eFRV8-04\/460\u003c\/a\u003e\u003c\/span\u003e - supply from all phases which means that relay is functional also in case when one phase is faulty\u003c\/li\u003e\n\u003cli\u003eVariant FRV 8-04\/265 - supply  L1-N, means that relay monitors also failure of neutral wire\u003c\/li\u003e\n\u003cli\u003e1-MODULE, DIN rail mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eFRV 8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSupply and measuring\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eL1, L2, L3 (127,132,138,220,230,240,254,265VAC)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSupply terminals\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eL1, L2, L3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSupply\/measured voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e3 x 127-265 V (L-N) \/ 50 Hz \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eLevel U\u003csub\u003emax\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e105 - 125 % U\u003csub\u003en\u003c\/sub\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eLevel U\u003csub\u003emin\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e75 - 95 % U\u003csub\u003en\u003c\/sub\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eBurden\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003emax. 2 VA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eHysteresis\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e2 %\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #80abdf;\"\u003e\u003cstrong\u003eMax. permanent overload\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eAC 3 x 265 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePeak overload \u0026lt;1ms\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eAC 3 x 265 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTime delay T1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003emax. 500 ms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTime delay T2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eadjustable 0.1-10 s\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #80aade;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of contacts\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e1 x changeover\/ SPDT (AgNi \/ Silver Alloy)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e10 A \/ AC1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eBreaking capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e2500 VA \/ AC1, 240 W \/ DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e10 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSwitching voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e250 V AC1 \/ 24 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMin. breaking capacity DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e500 mW\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eIndication of state\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003ered LED\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #80abdf;\"\u003e\u003cstrong\u003eMechanical life\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e1 x 10\u003csup\u003e7\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical life (AC1)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e1 x 10\u003csup\u003e5\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOther information\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e-20 ... +55 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e-30 ... +70 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical strength\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e4 kV (supply - output)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating position\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eany\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eDIN rail EN 60715\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eProtection degree\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eIP 40 from front panel \/ IP 10 terminals\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOvervoltage cathegory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eIII.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMax. cable size (mm )\u003csup\u003e2\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003esolid wire max. 2x2.5 or 1x4  ;  with sleeve max. 1x2.5 or 2x1.5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e90 x 17,6 x 64 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e69 g\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eEN 60255-6, EN 61010-1, RoHS, CE, CE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584407807\/Fastron%20Stuff\/Relays\/FRV_Voltage_Monitoring_Relay_3_Phase.pdf\" target=\"_blank\" title=\"Fastron FRV Datasheet\" rel=\"noopener noreferrer\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584407817\/Fastron%20Stuff\/Relays\/Fastron_Time_Relays_-_Full_Catalogue_WEB_version.pdf\" title=\"Fastron Monitoring Relays Catalogue\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eFastron Monitoring\/Time Relays Catalogue\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: #000000;\"\u003e For items in our catalogue which are not listed online please\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/pages\/contact-us\" title=\"Contact Fastron\" style=\"color: #2b00ff;\"\u003eContact Us for Possible Replacement\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003eRelay in 3-phase main monitors size of phase voltage.  It is possible to set two independent voltage levels and thus it is possible to set two independent voltage levels and monitor e.g. undervoltage and overvoltage independently. In normal state when voltage is within set levels, output relay is closed and red LED shines.\u003c\/p\u003e\n\u003cp\u003eIn case  voltage exceeds or falls below the set levels, output relay opens and red LED shines ( LED indicates faulty state – flashes when timing). In case supply voltage falls below 60 % Un (U\u003csub\u003eOFF\u003c\/sub\u003e lower level)relay immediately opens without delay and faulty state is indicated by red LED.In case timing is in progress and faulty state is indicated, timing is immediately stopped.\u003c\/p\u003e","brand":"Fastron Electronics","offers":[{"title":"Default Title","offer_id":31453351477382,"sku":"FE-FRV 8-04\/265","price":65.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FRV8-04_side_Angle265V_ac69e072-17cb-4b44-b916-ac5b9f833184.png?v=1659332177"},{"product_id":"84903020","title":"84903020, Three Phase Voltage Control Relay Phase Sequence or Phase Failure - 17.5 mm EMWS, 208-480 VAC, Self Powered","description":"\u003ch1\u003e\u003cspan style=\"color: #7bb1de;\"\u003e\u003cstrong\u003eCrouzet Automation 84903020, Three Phase Voltage Control Relay, Phase Sequence or Phase Failure - 17.5 mm EMWS, 208-480 VAC, Self Powered\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eFor Phase Sequence of Phase Failure Monitoring of AC Voltages up to 480VAC\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #7bb1de;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eControl Monitoring of AC voltages\u003c\/li\u003e\n\u003cli\u003eAutomatic recognition of AC\u003c\/li\u003e\n\u003cli\u003eMeasurement ranges from 288 V to 480 VAC\u003c\/li\u003e\n\u003cli\u003eChoice between under and overvoltage\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement\u003c\/li\u003e\n\u003cli\u003eSelectable latching (memory) function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e84903020 (Three Phase C-Lynx Voltage Monitoring Relay With SPDT Contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Sequence\/Phase Failure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x 208 - 480 VAC\/DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x C\/O Relays, 250VAC\/DC @ 5 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMin Breaking Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10mA\/5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDelay on Threshhold Crossing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 \u003cspan\u003e→ 3s (0, +10%)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eDelay on Pickup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAlarm Delay on Time (max)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eReset Time \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAdjustable Hysteresis\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5 - 50% of Threshhold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMaximum Measurement Cycle Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e30ms\/True RMS Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMeasurement Accuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSame as Measurement \u003cspan\u003e3 x 220 → 3 x 480 V ∿\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, GL, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOver Voltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in accordance with IEC\/EN 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in accordance with IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (Front), IP20 (Rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMechanical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunity to vibrations IEC\/EN 60068-2-6, test Fc\u003c\/p\u003e\n\u003cp\u003eImmunity to shock IEC\/EN 60068-2-27, test Ea\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C  except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1588640750\/Crouzet%20Automation\/Datasheets\/phase-sequence-phase-failure-84903020.pdf\" title=\"Crouzet Automation 84903020 Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Crouzet Automation","offers":[{"title":"Default Title","offer_id":31604376043654,"sku":"FE-84903020","price":156.43,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/images.jpg?v=1624861557"},{"product_id":"84872142","title":"84872142, Single Phase Voltage Control Relay Under\/Overvoltage Detection - 17.5 mm MUS, 65-260 VAC\/DC Measurement\/Supply, Replaces DSR2 Series","description":"\u003ch1\u003e\n\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Automation 84872152, Single Phase Voltage Control Relay Under\/Overvoltage Detection - 17.5 mm MUS, 65-260 VAC\/DC Measurement\/Supply\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"color: #7bb1de;\"\u003e\u003cstrong\u003e, Replaces DSR2 Series\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eFor under and over voltage monitoring of Single phase AC or DC Voltages 65 to 260V\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eControl of AC and DC voltages\u003c\/li\u003e\n\u003cli\u003eAutomatic recognition of AC\/DC\u003c\/li\u003e\n\u003cli\u003eMeasurement ranges from 65 V to 260 V\u003c\/li\u003e\n\u003cli\u003eChoice between under and over voltage\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement\u003c\/li\u003e\n\u003cli\u003eSelectable latching (memory) function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 508px;\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003e84872142 (Single Phase MUSF Voltage Monitoring Relay With Non-Latching SPDT Contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003eUndervoltage\/Overvoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003e\u003cspan\u003e65 - 260 VAC\/DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cstrong\u003eMeasurement Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003e\u003cspan\u003e1 x 15-600VAC\/DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003e\u003cspan\u003e1 x C\/O Relays, 250VAC\/DC @ 5 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cstrong\u003eMin Breaking Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003e10mA\/5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cstrong\u003eDelay on Threshhold Crossing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003e0.1 \u003cspan\u003e→ 3s (0, +10%)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cb\u003eDelay on Pickup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003e600ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cb\u003eAlarm Delay on Time (max)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003e200ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cb\u003eReset Time \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003e1500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cb\u003eAdjustable Hysteresis\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003e5 - 50% of Threshhold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cb\u003eMaximum Measurement Cycle Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003e30ms\/True RMS Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cb\u003eMeasurement Accuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003eSame as Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003e170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003eCE, UL, CSA, GL, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cstrong\u003eOver Voltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003e3 in accordance with IEC\/EN 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003e2 in accordance with IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003eIP40 (Front), IP20 (Rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cstrong\u003eMechanical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003e\n\u003cp\u003eImmunity to vibrations IEC\/EN 60068-2-6, test Fc\u003c\/p\u003e\n\u003cp\u003eImmunity to shock IEC\/EN 60068-2-27, test Ea\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 182px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 320px;\"\u003e-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1596008085\/Crouzet%20Automation\/Datasheets\/17-5-mm-mus-musf-260-ac-dc-Part_number-84872152_Single_phase_voltage.pdf\" title=\"Crouzet Automation 84872142 Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Crouzet Automation","offers":[{"title":"Default Title","offer_id":34704235462790,"sku":"FE-84872142","price":267.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/R6149460-01_1_8171a897-c2a6-46a7-bc76-a05d6cfb2d7b.jpg?v=1679271409"},{"product_id":"84873222","title":"84873222, 3 Phase Voltage Monitoring Relay With 17.5mm SPDT Contacts, 3 x 208 - 480 V AC M3US, Under\/Over","description":"\u003ch1\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eCrouzet 84873222 3 Phase C-Lynx Voltage Monitoring Relay With 17.5mm SPDT Contacts, 3 x 208 - 480 V AC M3US, Under\/Over \u003c\/span\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eH3US and M3US relays control, on 3-phase networ\u003c\/strong\u003eks :\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOvervoltage between phases,\u003c\/li\u003e\n\u003cli\u003eUndervoltage between phases\u003c\/li\u003e\n\u003cli\u003eThe H3USN relay controls, on 3-phase networks :\u003c\/li\u003e\n\u003cli\u003eOvervoltage between phases and neutral,\u003c\/li\u003e\n\u003cli\u003eUndervoltage between phases and neutral,\u003c\/li\u003e\n\u003cli\u003eLoss of neutral\u003c\/li\u003e\n\u003cli\u003eMulti-voltage Products\u003c\/li\u003e\n\u003cli\u003eControls its own supply voltage\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement\u003c\/li\u003e\n\u003cli\u003eLED status indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e3-phase voltage controllers which monitor : \u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eUndervoltage, adjustable from -20 to -2 % of Un \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOvervoltage, adjustable from 2 to 20 % of Un \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePresence of the neutral (H3USN only) Measurements are taken between Phases for the H3US \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eM3US and between Phases and Neutral for the H3USN Faults are signalled via LEDs, distinguishing the origin of the fault (one LED for the upper threshold, one LED for the lower threshold). Set the selector switch to the 3-phase network voltage Un. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe position of this selector switch is only taken into account when the unit is powered up. If the switch position changes while the unit is operating, all the LEDs flash but the product continues to work normally with the voltage selected on energisation prior to the change of position. The LEDs return to their normal state if the switch is reset to its initial position defined before the last energisation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e84873222 (3 Phase Voltage Monitoring Relay With SPDT Contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUndervoltage\/Overvoltage between phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 x 208 → 3 x 480 V ∿\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x C\/O Relays, 250VAC\/DC @ 5 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMin Breaking Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10mA\/5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTiming Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 \u003cspan\u003e→ 30s (0, +10%)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eDelay on Pickup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAlarm Delay on Time (max)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eReset Time \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eFixed Hysteresis\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2% of Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMaximum Measurement Cycle Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e150ms\/True RMS Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMeasurement Accuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSame as Measurement \u003cspan\u003e3 x 208 → 3 x 480 V ∿\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, GL, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOver Voltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in accordance with IEC\/EN 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in accordance with IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (Front), IP20 (Rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMechanical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunity to vibrations IEC\/EN 60068-2-6, test Fc\u003c\/p\u003e\n\u003cp\u003eImmunity to shock IEC\/EN 60068-2-27, test Ea\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C  except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1617260917\/Crouzet%20Automation\/Datasheets\/monitoring-relays-3-phase-monitoring-relays-din-rail-mount-17-5-mm-35-mm-3-phase-voltage-control-m3us-Part_number-84873222.pdf\" title=\"Crouzet Automation 84873222 Datasheet\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003ctable style=\"width: 29.4011%; float: left;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 10%; text-align: right;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%; text-align: right;\"\u003e\u003cstrong\u003eLegend\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eOvervoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eHysteresis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eUndervoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003ePhases L1, L2, L3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e5\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eRelay R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eRelay R2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eOvervoltage threshold delay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eUndervoltage threshold delay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align: right;\"\u003e \u003c\/p\u003e\n\u003cdiv class=\"panel-heading\" style=\"text-align: right;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"panel-body\" style=\"text-align: right;\"\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: right;\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/CO_RMC2_H3US_N_N1_large.jpg?v=1560665492\" alt=\"84873220 Application Note\" width=\"312\" height=\"166\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe relay monitors its own supply voltage. It controls :  \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eUndervoltage, adjustable from - 2 to - 20 % of Un (-2 to -12 % over the 3 x 220 V ∿ range due to the minimum voltage 194 V ∿)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOvervoltage, adjustable from + 2 to +20 %  (+2 to +10 %  over the 3 x 480 V ∿ range due to the maximum voltage 528 V ∿). Each threshold has its own time delay with independent setting between 0.3 and 30 s. In the event of a voltage fault, the corresponding relay (one undervoltage output\/one overvoltage output) opens at the end of the time delay set by the user. In the event of phase failure, both relays open instantaneously, without waiting for the end of the time delay. The two relay LEDs go out. The relay monitors its own supply voltage. It controls :   \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePresence of the neutral, - Undervoltage, adjustable from -2 to -20 % of Un, - Overvoltage, adjustable from +2 to +20 %.  Each threshold has its own time delay with independent setting between 0.3 and 30 s. In the event of a voltage fault, the corresponding relay (one undervoltage output\/one overvoltage output) opens at the end of the time delay set by the user. If neutral is lost, both relays open instantaneously and the corresponding LED is extinguished, without waiting for the end of the time delay. The two relay LEDs are extinguished.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Crouzet Automation","offers":[{"title":"Default Title","offer_id":34704249192582,"sku":"FE-84873222","price":359.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/Chonos2Multi_93b0b4fd-6804-47e8-8923-4ec1ab81acd0.png?v=1679273131"},{"product_id":"frv-8-02-ad240","title":"FRV 8-02\/AD240, 50 to 270VAC Voltage Monitoring Relay, Single Phase Over\/Under Voltage Detection, 1 x CO SPDT 10 Amp Contact, Adjustable Timer Delay, Adjustable Upper and Lower Voltage Limits","description":"\u003ch1\u003e\u003cspan style=\"color: #7aa4d6;\"\u003e\u003cstrong\u003eFastron FRV 8-02\/AD240, 50 to 270VAC Voltage Monitoring Relay, Single Phase Over\/Under Voltage Detection, 1 x CO SPDT 10 Amp Contact, Adjustable Timer Delay, Adjustable Upper and Lower Voltage Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eFRV 8 Series serves to monitor under\/over voltage in  switchboards, protection of devices in single phase 2 wire mains\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #7ca6d9;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUpper and lower level of monitoring voltage\u003c\/li\u003e\n\u003cli\u003eAdjustable time delay eliminates short voltage peaks and failures in the main\u003c\/li\u003e\n\u003cli\u003eSupply is done from monitored voltage\u003c\/li\u003e\n\u003cli\u003eFaulty state is indicated by red LED and by opening of output relay contact\u003c\/li\u003e\n\u003cli\u003eOutput contact  1 x Changeover \/ SPDT 10 A \/250 V AC1\u003c\/li\u003e\n\u003cli\u003eIn case supply voltage falls below  60 %Un (U lower level) relay \u003csub\u003eoff \u003c\/sub\u003e    immediately opens without delay\u003c\/li\u003e\n\u003cli\u003e1-MODULE, DIN rail mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eFRV 8-02\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSupply and measuring\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e50-270VAC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMeasured voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e65-260VAC  \/ 50 Hz \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eLevel U\u003csub\u003emax\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e112.5 % U\u003csub\u003en\u003c\/sub\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eLevel U\u003csub\u003emin\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e83 % U\u003csub\u003en\u003c\/sub\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eBurden\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003emax. 2 VA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eHysteresis\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e2 %\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #80abdf;\"\u003e\u003cstrong\u003eMax. permanent overload\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e270 VAC\/DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTime delay T1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003emax. 500 ms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTime delay T2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eadjustable 0.1-10 s\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #80aade;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of contacts\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e1 x changeover\/ SPDT (AgNi \/ Silver Alloy)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e10 A \/ AC1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eBreaking capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e2500 VA \/ AC1, 240 W \/ DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e10 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSwitching voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e250 V AC1 \/ 24 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMin. breaking capacity DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e500 mW\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eIndication of state\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003ered LED\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #80abdf;\"\u003e\u003cstrong\u003eMechanical life\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e1 x 10\u003csup\u003e7\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical life (AC1)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e1 x 10\u003csup\u003e5\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOther information\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e-20 ... +55 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e-30 ... +70 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical strength\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e4 kV (supply - output)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating position\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eany\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eDIN rail EN 60715\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eProtection degree\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eIP 40 from front panel \/ IP 10 terminals\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOvervoltage cathegory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eIII.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMax. cable size (mm )\u003csup\u003e2\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003esolid wire max. 2x2.5 or 1x4  ;  with sleeve max. 1x2.5 or 2x1.5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e90 x 17,6 x 64 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e69 g\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eEN 60255-6, EN 61010-1, RoHS, CE, CE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Fastron FRV Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584407808\/Fastron%20Stuff\/Relays\/FRV_Voltage_Monitoring_Relay_Single_Phase.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"Fastron Monitoring Relays Catalogue\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584407817\/Fastron%20Stuff\/Relays\/Fastron_Time_Relays_-_Full_Catalogue_WEB_version.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eFastron Monitoring\/Time Relays Catalogue\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: #000000;\"\u003e For items in our catalogue which are not listed online please\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Contact Fastron\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/pages\/contact-us\"\u003eContact Us for Possible Replacement\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003eRelay in 3-phase main monitors size of phase voltage.  It is possible to set two independent voltage levels and thus it is possible to set two independent voltage levels and monitor e.g. undervoltage and overvoltage independently. In normal state when voltage is within set levels, output relay is closed and red LED shines.\u003c\/p\u003e\n\u003cp\u003eIn case  voltage exceeds or falls below the set levels, output relay opens and red LED shines ( LED indicates faulty state – flashes when timing). In case supply voltage falls below 60 % Un (U\u003csub\u003eOFF\u003c\/sub\u003e lower level)relay immediately opens without delay and faulty state is indicated by red LED.In case timing is in progress and faulty state is indicated, timing is immediately stopped.\u003c\/p\u003e","brand":"Fastron Electronics","offers":[{"title":"Default Title","offer_id":34706123260038,"sku":"FE-FRV 8-02\/AD240","price":55.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FRV8-04_side_Angle265V.png?v=1659332140"},{"product_id":"mg73bq","title":"MG73BQ 3 Phase 4 Wire or Single Phase Voltage Monitoring Relay With DPDT Contacts, Undervoltage, Selectable Overvoltage, 3 x 120-240 VAC","description":"\u003ch1\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eGIC Controls MG73BQ 3 Phase 4 Wire or Single Phase Voltage Monitoring Relay With DPDT Contacts, Undervoltage, Selectable Overvoltage, 3 x 120-240 VAC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eRelay control, on 3-phase networ\u003c\/strong\u003eks :\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOvervoltage between phases,\u003c\/li\u003e\n\u003cli\u003eUndervoltage between phases\u003c\/li\u003e\n\u003cli\u003eOvervoltage between phases and neutral,\u003c\/li\u003e\n\u003cli\u003eUndervoltage between phases and neutral,\u003c\/li\u003e\n\u003cli\u003eLoss of neutral\u003c\/li\u003e\n\u003cli\u003eMulti-voltage Products\u003c\/li\u003e\n\u003cli\u003eControls its own supply voltage\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement\u003c\/li\u003e\n\u003cli\u003eLED status indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e3-phase voltage controllers which monitor : \u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eUndervoltage, adjustable from -20 to -2 % of Un \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOvervoltage, adjustable from 2 to 20 % of Un \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMeasurements are taken between neautral and Phases for MG73BQ\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eMG73BQ and between Phases and Neutral for the H3USN Faults are signalled via LEDs, distinguishing the origin of the fault (one LED for the upper threshold, one LED for the lower threshold). Set the selector switch to the 3-phase network voltage Un. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe position of this selector switch is only taken into account when the unit is powered up. If the switch position changes while the unit is operating, all the LEDs flash but the product continues to work normally with the voltage selected on energisation prior to the change of position. The LEDs return to their normal state if the switch is reset to its initial position defined before the last energisation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eGIC Controls Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eMG73BQ (3 Phase 4 Wire\/Single Phase Monitoring Relay With DPDT Contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUndervoltage\/Overvoltage between phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 x 120 → 3 x 240 V ∿\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x C\/O Relays, 250VAC\/DC @ 5 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMin Breaking Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10mA\/5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTiming Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 \u003cspan\u003e→ 30s (0, +10%)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eDelay on Pickup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAlarm Delay on Time (max)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eReset Time \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eFixed Hysteresis\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2% of Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMaximum Measurement Cycle Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e150ms\/True RMS Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMeasurement Accuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSame as Measurement \u003cspan\u003e3 x 220 → 3 x 480 V ∿\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, GL, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOver Voltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in accordance with IEC\/EN 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in accordance with IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (Front), IP20 (Rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMechanical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunity to vibrations IEC\/EN 60068-2-6, test Fc\u003c\/p\u003e\n\u003cp\u003eImmunity to shock IEC\/EN 60068-2-27, test Ea\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1710477210\/GIC%20Controls\/Datasheets\/Voltage_Monitoring_Series_SM_500.pdf\" target=\"_blank\" title=\"GIC Controls SM 500 Datasheet\" rel=\"noopener\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet﻿\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GIC Controls","offers":[{"title":"Default Title","offer_id":34746610417798,"sku":"FE-MG73BQ","price":179.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/SM500.jpg?v=1660776653"},{"product_id":"84873026","title":"84873026, 3 Phase C-Lynx Voltage Monitoring Relay With 2 x SPDT Contacts, 3 x 220 - 480 V AC HWUA","description":"\u003ch1\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eCrouzet 84873026 3 Phase C-Lynx Voltage Monitoring Relay With 2 x SPDT Contacts, 3 x 220 - 480 V AC HWUA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eHWUA relays control, on 3-phase networks :\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOvervoltage between phases,\u003c\/li\u003e\n\u003cli\u003eUndervoltage between phases\u003c\/li\u003e\n\u003cli\u003eThe HWUA relay controls, on 3-phase networks :\u003c\/li\u003e\n\u003cli\u003eOvervoltage between phases and neutral,\u003c\/li\u003e\n\u003cli\u003eUndervoltage between phases and neutral\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePhase asymmetry\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eLoss of neutral\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIndependant settings\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eMulti-voltage Products\u003c\/li\u003e\n\u003cli\u003eControls its own supply voltage\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement\u003c\/li\u003e\n\u003cli\u003eLED status indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e3-phase voltage controllers which monitor : \u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eUndervoltage, adjustable from -20 to -2 % of Un \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOvervoltage, adjustable from 2 to 20 % of Un\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eSet the selector switch to the 3-phase network voltage Un. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe position of this selector switch is only taken into account when the unit is powered up. If the switch position changes while the unit is operating, all the LEDs flash but the product continues to work normally with the voltage selected on energisation prior to the change of position. The LEDs return to their normal state if the switch is reset to its initial position defined before the last energisation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e84873026 (3 Phase C-Lynx Voltage Monitoring Relay With SPDT Contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUndervoltage\/Overvoltage between phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 x 220 → 3 x 480 V ∿\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x C\/O Relays, 250VAC\/DC @ 5 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMin Breaking Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10mA\/5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTiming Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 \u003cspan\u003e→ 30s (0, +10%)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eDelay on Pickup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAlarm Delay on Time (max)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eReset Time \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eFixed Hysteresis\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2% of Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMaximum Measurement Cycle Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e150ms\/True RMS Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMeasurement Accuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSame as Measurement \u003cspan\u003e3 x 220 → 3 x 480 V ∿\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, GL, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOver Voltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in accordance with IEC\/EN 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in accordance with IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (Front), IP20 (Rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMechanical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunity to vibrations IEC\/EN 60068-2-6, test Fc\u003c\/p\u003e\n\u003cp\u003eImmunity to shock IEC\/EN 60068-2-27, test Ea\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Crouzet Automation 84873026 Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1598339915\/Crouzet%20Automation\/Datasheets\/HWUA.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003ctable style=\"width: 29.4011%; float: left;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 10%; text-align: right;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%; text-align: right;\"\u003e\u003cstrong\u003eLegend\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eOvervoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eHysteresis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eUndervoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003ePhases L1, L2, L3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e5\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eRelay R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eRelay R2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eOvervoltage threshold delay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eUndervoltage threshold delay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align: right;\"\u003e \u003c\/p\u003e\n\u003cdiv style=\"text-align: right;\" class=\"panel-heading\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: right;\" class=\"panel-body\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: right;\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"166\" width=\"312\" alt=\"84873220 Application Note\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/CO_RMC2_H3US_N_N1_large.jpg?v=1560665492\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe relay monitors its own supply voltage. It controls :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eUndervoltage, adjustable from - 2 to - 20 % of Un (-2 to -12 % over the 3 x 220 V ∿ range due to the minimum voltage 194 V ∿)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOvervoltage, adjustable from + 2 to +20 % (+2 to +10 % over the 3 x 480 V ∿ range due to the maximum voltage 528 V ∿). Each threshold has its own time delay with independent setting between 0.3 and 30 s. In the event of a voltage fault, the corresponding relay (one undervoltage output\/one overvoltage output) opens at the end of the time delay set by the user. In the event of phase failure, both relays open instantaneously, without waiting for the end of the time delay. The two relay LEDs go out. The relay monitors its own supply voltage. It controls : \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePresence of the neutral, - Undervoltage, adjustable from -2 to -20 % of Un, - Overvoltage, adjustable from +2 to +20 %. Each threshold has its own time delay with independent setting between 0.3 and 30 s. In the event of a voltage fault, the corresponding relay (one undervoltage output\/one overvoltage output) opens at the end of the time delay set by the user. If neutral is lost, both relays open instantaneously and the corresponding LED is extinguished, without waiting for the end of the time delay. The two relay LEDs are extinguished.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Crouzet Automation","offers":[{"title":"Default Title","offer_id":34750371332230,"sku":"FE-84873026","price":380.31,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/PH_RMC2_HUH.jpg?v=1679271782"},{"product_id":"84872140-single-phase-voltage-control-relay-under-overvoltage-detection-17-5-mm-mus-15-600vac-dc-measurement-12vdc-supply","title":"84872140, Single Phase Voltage Control Relay Under\/Overvoltage Detection - 17.5 mm MUS, 15-600VAC\/DC Measurement, 12VDC Supply, 1 x C\/O Relays, 250VAC\/DC @ 5 Amp","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Automation 84872140, Single Phase Voltage Control Relay Under\/Over Voltage Detection - 17.5 mm MUS, 15-600VAC\/DC Measurement, 12VDC Supply, 1 x C\/O Relays, 250VAC\/DC @ 5 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eFor under and over voltage monitoring of Single phase AC or DC Voltages 65 to 260V\u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eControl of AC and DC voltages\u003c\/li\u003e\n\u003cli\u003eAutomatic recognition of AC\/DC\u003c\/li\u003e\n\u003cli\u003eMeasurement ranges from 65 V to 260 V\u003c\/li\u003e\n\u003cli\u003eChoice between under and over voltage\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement\u003c\/li\u003e\n\u003cli\u003eSelectable latching (memory) function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e84872140 (Single Phase MUS Voltage Monitoring Relay With Non-Latching SPDT Contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUndervoltage\/Overvoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12VDC\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMeasurement Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x 15 - 600 VAC\/DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x C\/O Relays, 250VAC\/DC @ 5 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMin Breaking Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10mA\/5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDelay on Threshhold Crossing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 \u003cspan\u003e→ 3s (0, +10%)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eDelay on Pickup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAlarm Delay on Time (max)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eReset Time \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAdjustable Hysteresis\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5 - 50% of Threshhold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMaximum Measurement Cycle Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e30ms\/True RMS Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMeasurement Accuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSame as Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, GL, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOver Voltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in accordance with IEC\/EN 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in accordance with IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (Front), IP20 (Rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMechanical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunity to vibrations IEC\/EN 60068-2-6, test Fc\u003c\/p\u003e\n\u003cp\u003eImmunity to shock IEC\/EN 60068-2-27, test Ea\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Crouzet Automation 84872142 Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1596008085\/Crouzet%20Automation\/Datasheets\/17-5-mm-mus-musf-260-ac-dc-Part_number-84872152_Single_phase_voltage.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Crouzet Automation","offers":[{"title":"Default Title","offer_id":34914452013190,"sku":"FE-84872140","price":309.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/R6149460-01_1_4bfa8ad5-1efe-4b17-9167-b8eb3b4802aa.jpg?v=1679271386"},{"product_id":"84872141","title":"84872141, Single Phase Voltage Control Relay Under\/Overvoltage Detection - 17.5 mm MUS, 15-600VAC\/DC Measurement, 24-48VAC\/DC Supply, 1 x C\/O Relays, 250VAC\/DC @ 5 Amp","description":"\u003ch1\u003e\u003cspan style=\"color: #7bb1de;\"\u003e\u003cstrong\u003eCrouzet Automation 84872141, Single Phase Voltage Control Relay Under\/Over Voltage Detection - 17.5 mm MUS, 15-600VAC\/DC Measurement, 24-48VAC\/DC Supply, 1 x C\/O Relays, 250VAC\/DC @ 5 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch1\u003e\u003cspan style=\"color: #7bb1de;\"\u003e\u003cstrong\u003e, Replaces DSR2 Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eFor under and over voltage monitoring of Single phase AC or DC Voltages 65 to 260V\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #7bb1de;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eControl of AC and DC voltages\u003c\/li\u003e\n\u003cli\u003eAutomatic recognition of AC\/DC\u003c\/li\u003e\n\u003cli\u003eMeasurement ranges from 15 V to 600 VAC\/DC\u003c\/li\u003e\n\u003cli\u003eChoice between under and over voltage\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement\u003c\/li\u003e\n\u003cli\u003eSelectable latching (memory) function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e84872141 (Single Phase MUS Voltage Monitoring Relay With Non-Latching SPDT Contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUndervoltage\/Overvoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24-48VAC\/DC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMeasurement Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x 15 - 600 VAC\/DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x C\/O Relays, 250VAC\/DC @ 5 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMin Breaking Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10mA\/5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDelay on Threshhold Crossing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 \u003cspan\u003e→ 3s (0, +10%)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eDelay on Pickup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAlarm Delay on Time (max)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eReset Time \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAdjustable Hysteresis\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5 - 50% of Threshhold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMaximum Measurement Cycle Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e30ms\/True RMS Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMeasurement Accuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSame as Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, GL, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOver Voltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in accordance with IEC\/EN 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in accordance with IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (Front), IP20 (Rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMechanical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunity to vibrations IEC\/EN 60068-2-6, test Fc\u003c\/p\u003e\n\u003cp\u003eImmunity to shock IEC\/EN 60068-2-27, test Ea\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Crouzet Automation 84872141 Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1760054635\/Crouzet%20Automation\/Datasheets\/EL_MR_VC_MUS80-MUS260_Datasheet_EN_84872141.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1596008085\/Crouzet%20Automation\/Datasheets\/17-5-mm-mus-musf-260-ac-dc-Part_number-84872152_Single_phase_voltage.pdf\" title=\"Crouzet Automation 84872142 Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eCross\u003c\/h5\u003e\n\u003cp\u003eReplaces DSR2 Series\u003c\/p\u003e","brand":"Crouzet Automation","offers":[{"title":"Default Title","offer_id":34914453192838,"sku":"FE-84872141","price":267.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/R6149460-01_1b58dda1-40f9-4d24-885e-d354227908c2_1.jpg?v=1679271371"},{"product_id":"84873024","title":"84873024, 3 Phase Voltage Monitoring Relay With 17.5mm SPDT Contacts, 3 x 208 - 480 V AC MWA, Sequence, Failure, Imbalance (asymmetry), Under\/Over","description":"\u003ch1\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eCrouzet 84873024, 3 Phase Voltage Monitoring Relay With 17.5mm SPDT Contacts, 3 x 208 - 480 V AC MWA, Sequence, Failure, Imbalance (asymmetry), Under\/Over\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eMWA relays control, on 3-phase networ\u003c\/strong\u003eks :\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOvervoltage between phases,\u003c\/li\u003e\n\u003cli\u003eUndervoltage between phases\u003c\/li\u003e\n\u003cli\u003eAsymmetry (Imbalance)\u003c\/li\u003e\n\u003cli\u003eSequence Detection\u003c\/li\u003e\n\u003cli\u003eControls its own supply voltage\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement\u003c\/li\u003e\n\u003cli\u003eLED status indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e3-phase voltage controllers which monitor : \u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eUndervoltage, adjustable from -20 to -2 % of Un \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOvervoltage, adjustable from 2 to 20 % of Un\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAsymmetry, adjustable from 5 to 15% of Selected Un\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePresence of the neutral (H3USN only) Measurements are taken between Phases for the H3US \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eM3US and between Phases and Neutral for the H3USN Faults are signalled via LEDs, distinguishing the origin of the fault (one LED for the upper threshold, one LED for the lower threshold). Set the selector switch to the 3-phase network voltage Un. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe position of this selector switch is only taken into account when the unit is powered up. If the switch position changes while the unit is operating, all the LEDs flash but the product continues to work normally with the voltage selected on energisation prior to the change of position. The LEDs return to their normal state if the switch is reset to its initial position defined before the last energisation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e84873224 (3 Phase Voltage Monitoring Relay With SPDT Contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUndervoltage\/Overvoltage between phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 x 208 → 3 x 480 V ∿\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x C\/O Relays, 250VAC\/DC @ 5 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMin Breaking Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10mA\/5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTiming Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 \u003cspan\u003e→ 30s (0, +10%)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eDelay on Pickup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAlarm Delay on Time (max)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eReset Time \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eFixed Hysteresis\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2% of Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMaximum Measurement Cycle Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e150ms\/True RMS Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMeasurement Accuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSame as Measurement \u003cspan\u003e3 x 208 → 3 x 480 V ∿\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, GL, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOver Voltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in accordance with IEC\/EN 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in accordance with IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (Front), IP20 (Rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMechanical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunity to vibrations IEC\/EN 60068-2-6, test Fc\u003c\/p\u003e\n\u003cp\u003eImmunity to shock IEC\/EN 60068-2-27, test Ea\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1620806577\/Crouzet%20Automation\/Datasheets\/3-phase-monitoring-relays84873024.pdf\" title=\"Crouzet Automation 84873024 Datasheet\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003ctable style=\"width: 29.4011%; float: left;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 10%; text-align: right;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%; text-align: right;\"\u003e\u003cstrong\u003eLegend\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eOvervoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eHysteresis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eUndervoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003ePhases L1, L2, L3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e5\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eRelay R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eRelay R2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eOvervoltage threshold delay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: right;\"\u003e\n\u003ctd style=\"width: 10%; text-align: center;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"width: 42.6717%;\"\u003e\u003cspan\u003eUndervoltage threshold delay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align: right;\"\u003e \u003c\/p\u003e\n\u003cdiv class=\"panel-heading\" style=\"text-align: right;\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel-body\" style=\"text-align: right;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: right;\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/CO_RMC2_H3US_N_N1_large.jpg?v=1560665492\" alt=\"84873220 Application Note\" width=\"312\" height=\"166\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe relay monitors its own supply voltage. It controls :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eUndervoltage, adjustable from - 2 to - 20 % of Un (-2 to -12 % over the 3 x 220 V ∿ range due to the minimum voltage 194 V ∿)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOvervoltage, adjustable from + 2 to +20 % (+2 to +10 % over the 3 x 480 V ∿ range due to the maximum voltage 528 V ∿). Each threshold has its own time delay with independent setting between 0.3 and 30 s. In the event of a voltage fault, the corresponding relay (one undervoltage output\/one overvoltage output) opens at the end of the time delay set by the user. In the event of phase failure, both relays open instantaneously, without waiting for the end of the time delay. The two relay LEDs go out. The relay monitors its own supply voltage. It controls : \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePresence of the neutral, - Undervoltage, adjustable from -2 to -20 % of Un, - Overvoltage, adjustable from +2 to +20 %. Each threshold has its own time delay with independent setting between 0.3 and 30 s. In the event of a voltage fault, the corresponding relay (one undervoltage output\/one overvoltage output) opens at the end of the time delay set by the user. If neutral is lost, both relays open instantaneously and the corresponding LED is extinguished, without waiting for the end of the time delay. The two relay LEDs are extinguished.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Crouzet Automation","offers":[{"title":"Default Title","offer_id":39289562005638,"sku":"FE-84873024","price":266.09,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/PH_RMC2_MWA_1.jpg?v=1679271507"},{"product_id":"frv-8-06-265","title":"FRV 8-06\/265, 127 to 265VAC L-N Voltage Monitoring Relay, 3 Phase 4 Wire Over\/Under Voltage Detection, Asymmetry, 1 x CO SPDT 8 Amp Contact, Fixed 2s Timer Delay, Adjustable Upper and Lower Voltage Limits, Adjustable Asymmetry","description":"\u003ch1\u003e\u003cspan style=\"color: #7aa4d6;\"\u003e\u003cstrong\u003eFastron FRV 8-06\/265, 127 to 265VAC L-N Voltage Monitoring Relay, 3 Phase 4 Wire Over\/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Fixed 2s Timer Delay, Adjustable Upper and Lower Voltage Limits, Adjustable Asymmetry\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eFRV 8 Series serves to monitor voltage, phase failure and sequence in     switchboards, protection of devices in 3-phase 4 wire mains\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #7ca6d9;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUpper and lower level of monitoring voltage\u003c\/li\u003e\n\u003cli\u003eAsymmetry\u003c\/li\u003e\n\u003cli\u003eAdjustable time delay eliminates short voltage peaks and failures in     the main\u003c\/li\u003e\n\u003cli\u003eSupply is done from monitored voltage\u003c\/li\u003e\n\u003cli\u003eFaulty state is indicated by red LED and by opening of output relay     contact\u003c\/li\u003e\n\u003cli\u003eOutput contact  1 x Changeover \/ SPDT 10 A \/250 V AC1\u003c\/li\u003e\n\u003cli\u003eIn case supply voltage falls below  60 %Un (U lower level) relay \u003csub\u003eoff \u003c\/sub\u003e    immediately opens without delay\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"FRV8-06\/460 Page\" href=\"frv8-06-460\"\u003e \u003cspan style=\"color: #2b00ff;\"\u003eFRV8-06\/460\u003c\/span\u003e\u003c\/a\u003e - supply from all phases which means that relay is functional also in case when one phase is faulty\u003c\/li\u003e\n\u003cli\u003eVariant FRV 8-04\/265 - supply  L1-N, means that relay monitors also failure of neutral wire\u003c\/li\u003e\n\u003cli\u003e1-MODULE, DIN rail mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eFRV 8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSupply and measuring\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eL1, L2, L3 (127,132,138,220,230,240,254,265VAC)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSupply terminals\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eL1, L2, L3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSupply\/measured voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e3 x 127-265 V (L-N) \/ 50 Hz \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eLevel U\u003csub\u003emax\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e105 - 125 % U\u003csub\u003en\u003c\/sub\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eLevel U\u003csub\u003emin\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e75 - 95 % U\u003csub\u003en\u003c\/sub\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eBurden\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003emax. 2 VA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eHysteresis\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e2 %\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #80abdf;\"\u003e\u003cstrong\u003eMax. permanent overload\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eAC 3 x 265 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePeak overload \u0026lt;1ms\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eAC 3 x 265 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTime delay T1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003emax. 500 ms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTime delay T2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eadjustable 0.1-10 s\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #80aade;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of contacts\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e1 x changeover\/ SPDT (AgNi \/ Silver Alloy)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e10 A \/ AC1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eBreaking capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e2500 VA \/ AC1, 240 W \/ DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e10 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSwitching voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e250 V AC1 \/ 24 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMin. breaking capacity DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e500 mW\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eIndication of state\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003ered LED\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #80abdf;\"\u003e\u003cstrong\u003eMechanical life\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e1 x 10\u003csup\u003e7\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical life (AC1)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e1 x 10\u003csup\u003e5\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOther information\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e-20 ... +55 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e-30 ... +70 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical strength\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e4 kV (supply - output)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating position\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eany\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eDIN rail EN 60715\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eProtection degree\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eIP 40 from front panel \/ IP 10 terminals\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOvervoltage cathegory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eIII.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMax. cable size (mm )\u003csup\u003e2\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003esolid wire max. 2x2.5 or 1x4  ;  with sleeve max. 1x2.5 or 2x1.5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e90 x 17,6 x 64 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e69 g\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eEN 60255-6, EN 61010-1, RoHS, CE, CE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584407807\/Fastron%20Stuff\/Relays\/FRV_Voltage_Monitoring_Relay_3_Phase.pdf\" target=\"_blank\" title=\"Fastron FRV Datasheet\" rel=\"noopener noreferrer\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"Fastron Monitoring Relays Catalogue\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584407817\/Fastron%20Stuff\/Relays\/Fastron_Time_Relays_-_Full_Catalogue_WEB_version.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eFastron Monitoring\/Time Relays Catalogue\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: #000000;\"\u003e For items in our catalogue which are not listed online please\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Contact Fastron\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/pages\/contact-us\"\u003eContact Us for Possible Replacement\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003eRelay in 3-phase main monitors size of phase voltage.  It is possible to set two independent voltage levels and thus it is possible to set two independent voltage levels and monitor e.g. undervoltage and overvoltage independently. In normal state when voltage is within set levels, output relay is closed and red LED shines.\u003c\/p\u003e\n\u003cp\u003eIn case  voltage exceeds or falls below the set levels, output relay opens and red LED shines ( LED indicates faulty state – flashes when timing). In case supply voltage falls below 60 % Un (U\u003csub\u003eOFF\u003c\/sub\u003e lower level)relay immediately opens without delay and faulty state is indicated by red LED.In case timing is in progress and faulty state is indicated, timing is immediately stopped.\u003c\/p\u003e","brand":"Fastron Electronics","offers":[{"title":"Default Title","offer_id":39322789511302,"sku":"FE-FRV 8-06\/265","price":71.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FRV8-04_side_Angle265V_3467e821-cd6b-4693-9720-24c831a9a783.png?v=1659332310"},{"product_id":"frv-8-06-460","title":"FRV 8-06\/460, 220-460VAC L-L Voltage Monitoring Relay, 3 Phase Over\/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Fixed 2s Timer Delay, Adjustable Upper and Lower Voltage Limits, Adjustable Asymmetry","description":"\u003ch1\u003e\u003cspan style=\"color: #7aa4d6;\"\u003e\u003cstrong\u003eFastron FRV 8-06\/460, 220-460VAC L-L Voltage Monitoring Relay, 3 Phase Over\/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Fixed 2s Timer Delay, Adjustable Upper and Lower Voltage Limits, Adjustable Asymmetry\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eFRV 8 Series serves to monitor voltage, phase failure and sequence in switchboards, protection of devices in 3-phase mains\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #7ca6d9;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUpper and lower level of monitoring voltage\u003c\/li\u003e\n\u003cli\u003eAsymmetry\u003c\/li\u003e\n\u003cli\u003eAdjustable time delay eliminates short voltage peaks and failures in     the main\u003c\/li\u003e\n\u003cli\u003eSupply is done from monitored voltage\u003c\/li\u003e\n\u003cli\u003eFaulty state is indicated by red LED and by opening of output relay     contact\u003c\/li\u003e\n\u003cli\u003eOutput contact  1 x Changeover \/ SPDT 10 A \/250 V AC1\u003c\/li\u003e\n\u003cli\u003eIn case supply voltage falls below  60 %Un (U lower level) relay \u003csub\u003eoff \u003c\/sub\u003e    immediately opens without delay\u003c\/li\u003e\n\u003cli\u003eFRV 8-04\/460 - supply from all phases which means that relay is functional also in case when one phase is faulty\u003c\/li\u003e\n\u003cli\u003eVariant \u003ca href=\"FRV%208-06-265\" title=\"FRV 8-06\/265 Page\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eFRV 8-06\/265\u003c\/span\u003e\u003c\/a\u003e - supply  L1-N, means that relay monitors also failure of neutral wire\u003c\/li\u003e\n\u003cli\u003e1-MODULE, DIN rail mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eFRV 8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSupply and measuring\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eL1, L2, L3 (220,230,240,380,400,415,440,460VAC)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSupply terminals\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eL1, L2, L3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSupply\/measured voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e3 x 220-460 V \/ 50 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eLevel U\u003csub\u003emax\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e105 - 125 % U\u003csub\u003en\u003c\/sub\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eLevel U\u003csub\u003emin\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e75 - 95 % U\u003csub\u003en\u003c\/sub\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eBurden\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003emax. 2 VA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eHysteresis\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e2 %\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #80abdf;\"\u003e\u003cstrong\u003eMax. permanent overload\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eAC 3 x 460 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePeak overload \u0026lt;1ms\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eAC 3 x 500 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTime delay T1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003emax. 500 ms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTime delay T2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eadjustable 0.1-10 s\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #80aade;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of contacts\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e1 x changeover\/ SPDT (AgNi \/ Silver Alloy)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e10 A \/ AC1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eBreaking capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e2500 VA \/ AC1, 240 W \/ DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInrush current\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e10 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSwitching voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e250 V AC1 \/ 24 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMin. breaking capacity DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e500 mW\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eIndication of state\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003ered LED\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #80abdf;\"\u003e\u003cstrong\u003eMechanical life\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e1 x 10\u003csup\u003e7\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical life (AC1)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e1 x 10\u003csup\u003e5\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOther information\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e-20 ... +55 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e-30 ... +70 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical strength\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e4 kV (supply - output)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating position\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eany\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eDIN rail EN 60715\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eProtection degree\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eIP 40 from front panel \/ IP 10 terminals\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOvervoltage cathegory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eIII.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eMax. cable size (mm )\u003csup\u003e2\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003esolid wire max. 2x2.5 or 1x4  ;  with sleeve max. 1x2.5 or 2x1.5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e90 x 17,6 x 64 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003e69 g\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 210px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 308px;\"\u003e\n\u003cp\u003eEN 60255-6, EN 61010-1, RoHS, CE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584407807\/Fastron%20Stuff\/Relays\/FRV_Voltage_Monitoring_Relay_3_Phase.pdf\" title=\"Fastron FRV Datasheet\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584407817\/Fastron%20Stuff\/Relays\/Fastron_Time_Relays_-_Full_Catalogue_WEB_version.pdf\" title=\"Fastron Monitoring Relays Catalogue\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eFastron Monitoring\/Time Relays Catalogue\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan style=\"color: #000000;\"\u003e For items in our catalogue which are not listed online please \u003c\/span\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/pages\/contact-us\" title=\"Contact Fastron\"\u003eContact Us for Possible Replacement\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003eRelay in 3-phase main monitors size of phase voltage.  It is possible to set two independent voltage levels and thus it is possible to set two independent voltage levels and monitor e.g. undervoltage and overvoltage independently. In normal state when voltage is within set levels, output relay is closed and red LED shines.\u003c\/p\u003e\n\u003cp\u003eIn case  voltage exceeds or falls below the set levels, output relay opens and red LED shines ( LED indicates faulty state – flashes when timing). In case supply voltage falls below 60 % Un (U\u003csub\u003eOFF\u003c\/sub\u003e lower level)relay immediately opens without delay and faulty state is indicated by red LED.In case timing is in progress and faulty state is indicated, timing is immediately stopped.\u003c\/p\u003e","brand":"Fastron Electronics","offers":[{"title":"Default Title","offer_id":39322791248006,"sku":"FE-FRV 8-06\/460","price":71.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FRV8-04_side_Angle460V_ce403c1c-5ac5-40f5-8b41-5073a17e9bca.png?v=1659332232"},{"product_id":"84873029","title":"84873029, 3 Phase Voltage Monitoring Relay With 17.5mm SPDT Contacts, 3 x 208 - 480 V AC MWA, Phase Sequence, Total Failure, Can Replace 84892290, 84873034","description":"\u003ch1\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eCrouzet 84873029, 3 Phase Voltage Monitoring Relay With 17.5mm SPDT Contacts, 3 x 208 - 480 V AC MWA, Phase Sequence, Total Failure, Can Replace  84892290, 84873034\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eRMC2 MWS relays control, on 3-phase networ\u003c\/strong\u003eks :\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSequence Detection\u003c\/li\u003e\n\u003cli\u003eTotal Phase Failure\u003c\/li\u003e\n\u003cli\u003eControls its own supply voltage\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement\u003c\/li\u003e\n\u003cli\u003eLED status indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e3-phase voltage controllers which monitor :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eNon Adjustable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e84873029 (3 Phase Voltage Monitoring Relay With SPDT Contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal Phase Failure, Phase Sequence\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 x 208 → 3 x 480 V ∿\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x C\/O Relays, 250VAC\/DC @ 5 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMin Breaking Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10mA\/5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTiming Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 \u003cspan\u003e→ 30s (0, +10%)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eDelay on Pickup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAlarm Delay on Time (max)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eReset Time \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eFixed Hysteresis\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2% of Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMaximum Measurement Cycle Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e150ms\/True RMS Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMeasurement Accuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSame as Measurement \u003cspan\u003e3 x 208 → 3 x 480 V ∿\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, GL, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOver Voltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in accordance with IEC\/EN 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in accordance with IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (Front), IP20 (Rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMechanical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunity to vibrations IEC\/EN 60068-2-6, test Fc\u003c\/p\u003e\n\u003cp\u003eImmunity to shock IEC\/EN 60068-2-27, test Ea\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1622429767\/Crouzet%20Automation\/Datasheets\/phase-sequence-phase-failure-mws-84873029.pdf\" title=\"Crouzet Automation 84873029 Datasheet\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Crouzet Automation","offers":[{"title":"Default Title","offer_id":39371788255366,"sku":"FE-84873029","price":197.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/84873034_430d9a45-e41a-47dd-a35d-2846e0607214.png?v=1679271589"},{"product_id":"84873034","title":"84873034, 3 Phase Voltage Monitoring Relay With 17.5mm DPDT Contacts, 3 x 230 - 460 V AC EWS2, Sequence, Failure, OBSOLETE WITH NO DIRECT REPLACEMENT, SEE 84873029 For Possible Replacement","description":"\u003ch1\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eCrouzet 84873034, 3 Phase Voltage Monitoring Relay With 17.5mm DPDT Contacts, 3 x 230 - 460 V AC EWS2, Sequence, Failure, OBSOLETE WITH NO DIRECT REPLACEMENT, SEE 84873029 For Possible Replacement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eEWS2 relays control, on 3-phase networ\u003c\/strong\u003eks :\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePhase Failure\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSequence Detection\u003c\/li\u003e\n\u003cli\u003eControls its own supply voltage\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement\u003c\/li\u003e\n\u003cli\u003eLED status indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e84873034 (3 Phase Voltage Monitoring Relay With DPDT Contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Sequence, Phase Failure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 x 230 → 3 x 460 V ∿\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x C\/O Relays, 250VAC\/DC @ 8 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMin Breaking Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10mA\/5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTiming Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eDelay on Pickup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAlarm Delay on Time (max)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eReset Time \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eFixed Hysteresis\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2% of Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMaximum Measurement Cycle Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e150ms\/True RMS Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMeasurement Accuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSame as Measurement \u003cspan\u003e3 x 208 → 3 x 480 V ∿\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, GL, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOver Voltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in accordance with IEC\/EN 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in accordance with IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (Front), IP20 (Rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMechanical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunity to vibrations IEC\/EN 60068-2-6, test Fc\u003c\/p\u003e\n\u003cp\u003eImmunity to shock IEC\/EN 60068-2-27, test Ea\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Crouzet Automation 84873034 Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1646266600\/Crouzet%20Automation\/Datasheets\/84873034-phase-sequence-phase-failure-ews2-Part_number-.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eAlternatives\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"84873029\" title=\"84873029 Voltage Monitoring Relay\" rel=\"noopener\" target=\"_blank\"\u003e84873029\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Crouzet Automation","offers":[{"title":"Default Title","offer_id":39705914048646,"sku":"FE-84873034","price":222.63,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/84873034.png?v=1646267359"},{"product_id":"84872120","title":"84872120, Single Phase Multi-Function Voltage Control Relay Under\/Overvoltage Detection and Latching (Memory) Function- 35 mm HUL, 0.2-60 VAC\/DC Measurement, 24\/240 VAC\/DC Supply","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Automation 84872120, Single Phase Multi-Function Voltage Control Relay Under\/Overvoltage Detection and Latching (Memory) Function- 35 mm HUL, 0.2-60 VAC\/DC Measurement, 24\/240 VAC\/DC Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eFor under and overvoltage monitoring of Single phase AC or DC Voltages up to 600V\u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #7bb1de;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eControl of AC and DC voltages\u003c\/li\u003e\n\u003cli\u003eAutomatic recognition of AC\/DC\u003c\/li\u003e\n\u003cli\u003eMeasurement ranges from 0.2 V to 60 V\u003c\/li\u003e\n\u003cli\u003eChoice between under and overvoltage\u003c\/li\u003e\n\u003cli\u003eTrue RMS measurement\u003c\/li\u003e\n\u003cli\u003eSelectable latching (memory) function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eCrouzet Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e84872120 (Single Phase C-Lynx Voltage Monitoring Relay With DPDT Contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUndervoltage\/Overvoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x 0.2 - 60 VAC\/DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x C\/O Relays, 250VAC\/DC @ 8 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMin Breaking Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10mA\/5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDelay on Threshhold Crossing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 \u003cspan\u003e→ 3s (0, +10%)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eDelay on Pickup\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAlarm Delay on Time (max)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eReset Time \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAdjustable Hysteresis\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5 - 50% of Threshhold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMaximum Measurement Cycle Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e30ms\/True RMS Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMeasurement Accuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSame as Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, GL, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOver Voltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in accordance with IEC\/EN 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in accordance with IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eProtection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (Front), IP20 (Rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMechanical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunity to vibrations IEC\/EN 60068-2-6, test Fc\u003c\/p\u003e\n\u003cp\u003eImmunity to shock IEC\/EN 60068-2-27, test Ea\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResistance to HF Interference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmunity to radiated electrostatic fields IEC\/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC\/EN 61000-4-4, level 3 Immunity to shock waves IEC\/EN 61000-4-5 Radio frequency in common mode IEC\/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC\/EN 61000-4-11 Immunity to damped oscillatory waves IEC\/EN 61000-4-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eConducted and radiated emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC\/EN 60068-2-1 and IEC\/EN 60068-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Crouzet Automation 84873120 Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1759708988\/Crouzet%20Automation\/Datasheets\/EL_MR_VC_HUL-EUL-HUH-EUH_Datasheet_EN.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Crouzet Automation","offers":[{"title":"Default Title","offer_id":42481167597702,"sku":null,"price":295.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/PH_RMC2_HUH_3c7f3f34-ab60-439e-a90f-f40b096ff657.jpg?v=1679271858"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/collections\/Crouzet_Timers_Relays_f8a74455-03a8-4f71-950c-e71200cd885b.png?v=1739485264","url":"https:\/\/fastron.com.au\/collections\/voltage-monitoring-relays.oembed?page=2","provider":"Fastron Electronics Store ","version":"1.0","type":"link"}