{"title":"Transient Voltage \u0026 RC Suppression","description":"\u003ch1\u003e\u003cspan style=\"color: #8abbe2;\"\u003e\u003cstrong\u003eTransient Voltage Suppression Diodes (TVS) \u0026amp; RC Suppressors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cbr\u003e\n\u003cp\u003eFind the best solution for over voltage and surge protection of AC and DC electrical components and electronic systems. Explore our range of Tranisent Suppression Diodes 7 RC Suppressors available from the team at Fastron Electronics.\u003c\/p\u003e\n\u003cp\u003eOur range of TVS Diodes are intended for use with Contactors, or Relays where coil suppression is required. For any size, voltage or type not listed, please \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"\/pages\/contact-us\/\" title=\"Contact Fastron\" style=\"color: #2b00ff;\"\u003econsult\u003c\/a\u003e\u003c\/span\u003e our sales team to find out about availability and a custom quote. Note for non stocked Diodes there may be a high MOQ, please check with the sales team\u003c\/p\u003e\n\u003cp\u003eYou can trust all of the products provided by Fastron Electronics. As well as the best products on the market, we offer a range of technical support, engineering services and solutions for you \u003cspan data-mce-fragment=\"1\"\u003ebased on decades in the local market.\u003c\/span\u003e.\u003c\/p\u003e","products":[{"product_id":"c100n-100r","title":"C100N+100R, RC Snubber Network 250VAC, 100uF 100 Ohm","description":"\u003ch1\u003e\u003cspan style=\"color: #99b5e0;\"\u003e\u003cstrong\u003eC100N+100R, RC Snubber Network 250VAC, 100uF 100 Ohm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eThese snubber neworks are suitable for transient supression in small contactors, bridge rectifers, or solid state relays switching AC or DC Loads. Easily connected or lugged to solid stage relay or power module terminals. See \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"\/collections\/schurter-line-filters\" title=\"EMC Filters\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eEMC filters\u003c\/a\u003e\u003c\/span\u003e, and \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"\/collections\/varistors\" title=\"Metal Oxide Varistors\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eMetal Oxide Varistors\u003c\/a\u003e\u003c\/span\u003e sections for additional supression components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eAs and added bonus, these Snubber Networks Improve the Power Factor of switched loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca title=\"KEMET RIFA C110N + 100R Snubbers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1646872471\/LeClanche\/Datasheets\/C100R.pdf\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\" data-mce-href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1646872471\/LeClanche\/Datasheets\/C100R.pdf\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LeClanche","offers":[{"title":"Default Title","offer_id":11010426962035,"sku":"FE-C100N+100R","price":7.2,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/leclanche-ssr-accessories-power-quality-snubber-capacitor-c100n-100r-snubber-network-250vac-100uf-100-ohm-13061708742790.jpg?v=1617936844"},{"product_id":"p6ke120ca","title":"P6KE120CA, Transient Voltage Supressions Diode (TVS), Bidirectional 120V 3.6 Amp DO-15 package","description":"\u003ch1\u003e\u003cspan style=\"color: #78aee1;\"\u003e\u003cstrong\u003eP6KE120CA, Transient Voltage Supressions Diode (TVS), 120V 3.6 Amp Bidirectional DO-15 package\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e600W Absorption Rating\u003c\/li\u003e\n\u003cli\u003eIndustry Standard DO-15 Package\u003c\/li\u003e\n\u003cli\u003e114-126V Rating\u003c\/li\u003e\n\u003cli\u003e100 Amp Peak Current Capability\u003c\/li\u003e\n\u003cli\u003ePCB Mount\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #89b4e2;\"\u003e\u003cstrong\u003e APPLICATION AREAS: \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e1.Used in sensitive electronics for protection against voltage transients indused by inductive load swithcing and lighting on IC's Mosfets, signal lines of sensors units for consumer, industrial, automotive, and telecommunications\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eP6KE120CA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDirection\/Polar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBidirectional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Voltage AC (50-60Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Voltage DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAverage Power Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePermissable Peak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eEnergy Absorption(2ms)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600W(max)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eTolerance(Vn)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAxial Lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Transorb Series Energy Absorbers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1604970905\/Bright%20King\/Bight_King_stock.pdf\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e \u003cbr\u003e\n\u003c\/h5\u003e","brand":"Bright King","offers":[{"title":"Default Title","offer_id":34868459208838,"sku":"FE-P6KE120CA","price":0.65,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/Transorb.jpg?v=1624864970"},{"product_id":"p6ke47ca-e3-54","title":"P6KE47CA-E3\/54, Transient Voltage Supressions Diode (TVS), Bidirectional 47V 9.3 Amp DO-15 package","description":"\u003ch1\u003e\u003cspan style=\"color: #78aee1;\"\u003e\u003cstrong\u003eP6KE47CA-E3\/54, Transient Voltage Supressions Diode (TVS), Bidirectional 47V 9.3 Amp DO-15 package\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e600W Absorption Rating\u003c\/li\u003e\n\u003cli\u003eIndustry Standard DO-15 Package\u003c\/li\u003e\n\u003cli\u003e44.7 - 49.4V Rating\u003c\/li\u003e\n\u003cli\u003e100 Amp Peak Current Capability\u003c\/li\u003e\n\u003cli\u003ePCB Mount\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #89b4e2;\"\u003e\u003cstrong\u003e APPLICATION AREAS: \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e1.Used in sensitive electronics for protection against voltage transients indused by inductive load swithcing and lighting on IC's Mosfets, signal lines of sensors units for consumer, industrial, automotive, and telecommunications\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eP6KE47CA-E3\/54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDirection\/Polar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBidirectional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Voltage AC (50-60Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Voltage DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAverage Power Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePermissable Peak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eEnergy Absorption(2ms)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600W(max)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eTolerance(Vn)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAxial Lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1604970905\/Bright%20King\/Bight_King_stock.pdf\" title=\"Transorb Series Energy Absorbers\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bright King","offers":[{"title":"Default Title","offer_id":34868470775942,"sku":"FE-P6KE47CA-E3\/54","price":0.65,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/Transorb_77788f6c-f668-46a1-a93c-3b25892d3c5a.jpg?v=1624864973"},{"product_id":"c100n-100r-lugged-3-pcs","title":"C100N+100R Lugged 3 pcs, RC Snubber Network 250VAC, 100uF 100 Ohm","description":"\u003ch1\u003e\u003cspan style=\"color: #7db6dc;\"\u003e\u003cstrong\u003eC100N+100R Lugged 3 pcs, RC Snubber Network 250VAC, 100uF 100 Ohm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eThese snubber neworks are suitable for transient supression in small contactors, bridge rectifers, or solid state relays switching AC or DC Loads. Easily connected or lugged to solid stage relay or power module terminals. See \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"\/collections\/schurter-line-filters\" title=\"EMC Filters\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eEMC filters\u003c\/a\u003e\u003c\/span\u003e, and \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"\/collections\/varistors\" title=\"Metal Oxide Varistors\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eMetal Oxide Varistors\u003c\/a\u003e\u003c\/span\u003e sections for additional supression components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eAs and added bonus, these Snubber Networks Improve the Power Factor of switched loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1646872471\/LeClanche\/Datasheets\/C100R.pdf\" target=\"_blank\" title=\"KEMET RIFA C110N + 100R Snubbers\" style=\"color: #2b00ff;\" rel=\"noopener noreferrer\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LeClanche","offers":[{"title":"Default Title","offer_id":34982681804934,"sku":"FE-C100N+100R-L-3pcs","price":25.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/leclanche-ssr-accessories-power-quality-snubber-capacitor-c100n-100r-snubber-network-250vac-100uf-100-ohm-13061708742790_02069f82-e577-4e41-b3d8-62aff48fd11c.jpg?v=1624865568"},{"product_id":"c100n-100r-lugged","title":"C100N+100R-Lugged, RC Snubber Network 250VAC, 100uF 100 Ohm Lugged for SSR or SCR Terminal Mounting","description":"\u003ch1\u003e\u003cspan style=\"color: #7db6dc;\"\u003e\u003cstrong\u003eC100N+100R-Lugged, RC Snubber Network 250VAC, 100uF 100 Ohm Lugged for SSR or SCR Terminal Mounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eThese snubber neworks are suitable for transient supression in small contactors, bridge rectifers, or solid state relays switching AC or DC Loads. Easily connected or lugged to solid stage relay or power module terminals. See \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"EMC Filters\" href=\"\/collections\/schurter-line-filters\" target=\"_blank\"\u003eEMC filters\u003c\/a\u003e\u003c\/span\u003e, and \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Metal Oxide Varistors\" href=\"\/collections\/varistors\" target=\"_blank\"\u003eMetal Oxide Varistors\u003c\/a\u003e\u003c\/span\u003e sections for additional supression components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eAs and added bonus, these Snubber Networks Improve the Power Factor of switched loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca title=\"KEMET RIFA C110N + 100R Snubbers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1646872471\/LeClanche\/Datasheets\/C100R.pdf\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\" data-mce-href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1646872471\/LeClanche\/Datasheets\/C100R.pdf\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LeClanche","offers":[{"title":"Default Title","offer_id":34982685933702,"sku":"FE-C100N+100R Lugged","price":6.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/leclanche-ssr-accessories-power-quality-snubber-capacitor-c100n-100r-snubber-network-250vac-100uf-100-ohm-13061708742790_0903f614-c720-46e3-9110-49b81b7cc9cf.jpg?v=1624865576"},{"product_id":"rc1-k0x-12-48vac","title":"RC1-K0x 12-48VAC, RC Snubber Network 12-48VAC, For KNL or other Contactors","description":"\u003ch1\u003e\u003cspan style=\"color: #6ea4d7;\"\u003e\u003cstrong\u003eRC1-K0x 12-48VAC, RC Snubber Network 12-48VAC, For KNL or other Contactors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eThese snubber neworks are suitable for transient supression in small contactors, bridge rectifers, or solid state relays switching AC. Easily connected or lugged to solid stage relay or power module terminals. See \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"\/collections\/schurter-line-filters\" title=\"EMC Filters\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eEMC filters\u003c\/a\u003e\u003c\/span\u003e, and \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"\/collections\/varistors\" title=\"Metal Oxide Varistors\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eMetal Oxide Varistors\u003c\/a\u003e\u003c\/span\u003e sections for additional supression components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eAs and added bonus, these Snubber Networks Improve the Power Factor of switched loads.\u003c\/span\u003e\u003c\/p\u003e","brand":"Iskra Doo","offers":[{"title":"Default Title","offer_id":35018318971014,"sku":"FE-RC1-K0x 12-48VAC","price":11.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/RCSnubber.jpg?v=1650947001"},{"product_id":"rc2-k0x-48-250vac","title":"RC2-K0x 48-250VAC, RC Snubber Network 48-250VAC, For KNL or other Contactors","description":"\u003ch1\u003e\u003cspan style=\"color: #6ea4d7;\"\u003e\u003cstrong\u003eRC2-K0x 48-250VAC, RC Snubber Network 48-250VAC, For KNL or other Contactors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eThese snubber neworks are suitable for transient supression in small contactors, bridge rectifers, or solid state relays switching AC. Easily connected or lugged to solid stage relay or power module terminals. See \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"\/collections\/schurter-line-filters\" title=\"EMC Filters\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eEMC filters\u003c\/a\u003e\u003c\/span\u003e, and \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"\/collections\/varistors\" title=\"Metal Oxide Varistors\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eMetal Oxide Varistors\u003c\/a\u003e\u003c\/span\u003e sections for additional supression components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eAs and added bonus, these Snubber Networks Improve the Power Factor of switched loads.\u003c\/span\u003e\u003c\/p\u003e","brand":"Iskra Doo","offers":[{"title":"Default Title","offer_id":35018319822982,"sku":"FE-RC2-K0x 48-250VAC","price":11.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/RCSnubber_c1cd4445-92be-4088-bd6f-570d8a330970.jpg?v=1650947005"},{"product_id":"rc4-k0x-380-600vac","title":"RC4-K0x 380-600VAC, RC Snubber Network 380-600VAC, For KNL or other Contactors","description":"\u003ch1\u003e\u003cspan style=\"color: #6ea4d7;\"\u003e\u003cstrong\u003eRC4-K0x 380-600VAC, RC Snubber Network 380-600VAC, For KNL or other Contactors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eThese snubber neworks are suitable for transient supression in small contactors, bridge rectifers, or solid state relays switching AC. Easily connected or lugged to solid stage relay or power module terminals. See \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"\/collections\/schurter-line-filters\" title=\"EMC Filters\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eEMC filters\u003c\/a\u003e\u003c\/span\u003e, and \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"\/collections\/varistors\" title=\"Metal Oxide Varistors\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eMetal Oxide Varistors\u003c\/a\u003e\u003c\/span\u003e sections for additional supression components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eAs and added bonus, these Snubber Networks Improve the Power Factor of switched loads.\u003c\/span\u003e\u003c\/p\u003e","brand":"Iskra Doo","offers":[{"title":"Default Title","offer_id":35018320085126,"sku":"FE-RC4-K0x 380-600VAC","price":11.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/RCSnubber_a59a4fd3-b2a6-49f3-ba52-81062976f6b5.jpg?v=1650947009"},{"product_id":"afp0rc14rs-8-x-on-off-inputs","title":"AFP0RC14RS, Progammabel Logic Controller (PLC) 8 x On\/Off inputs, 6 x Relay Outputs, 24VDC","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #6ea4d7;\"\u003eAFP0RC14RS, Progammabel Logic Controller (PLC) 8 x On\/Off inputs, 6 x Relay Outputs, 24VDC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAllow the use of the entire library of specific functions blocs of the software workshop\u003c\/li\u003e\n\u003cli\u003eExpandable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1721266419\/Panasonic\/AFP_PLC_Panasonic.pdf\" title=\"AFP0RC14RS Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eDatasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Panasonic","offers":[{"title":"Default Title","offer_id":41229028032646,"sku":"FE-AFP0RC14RS","price":379.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/AFP0RC14RS.jpg?v=1721265883"},{"product_id":"esct-rc150-3000a","title":"ESCT-RC150-3000A, Rogowski Coil, 150mm Diameter, 85mV\/kA Rated for 3000 Amp Recommended, 3 Meter Cable length","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eESCT-RC150-3000A, Rogowski Coil, 150mm Diameter, 85mV\/kA Rated for 3000 Amp Recommended, 3 Meter Cable length\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eFlexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and the secondary circuit (measurement). \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRated insulation voltage 1000 V Cat III PD2\u003c\/li\u003e\n\u003cli\u003eAccuracy Class 0.5 (IEC 61869-2)\u003c\/li\u003e\n\u003cli\u003eProtection degree IP67\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e3 m output cable (other lengths available see page 8)\u003c\/li\u003e\n\u003cli\u003eAmbient temperature 40 °C … +80 °C\u003c\/li\u003e\n\u003cli\u003eVery flexible and thin coil: 6.1 mm\u003c\/li\u003e\n\u003cli\u003eSlot for attaching the loop on the primary with a cable tie\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAn innovative patented clasp drastically reduces the positioning error near the closing\u003c\/li\u003e\n\u003cli\u003eInternal shield for enhanced measurement accuracy at low primary currents.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eThin, flexible, and light weight solution\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eVery low positioning error\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eQuick, non-intrusive and easy setup\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eA single sensor for a large current range without overload\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLess influenced by external fields\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAdaptable for a large range of cable diameters\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eMV\/LV substations on LV side: Transformer Condition Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003ePower metering: current measurement for active power calculation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eBuilding sub-metering: energy efficiency monitoring, consumption analysis and cost allocation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003ePower quality monitoring: electrical loads and distribution system equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eFault Detection, Isolation and Repair (FDIR): isolate the site of the fault\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eRemote Terminal Units (RTU)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003ePhasor Measurement Units (PMU)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eIEC 61010-1: 2010; IEC 61010-2-32 ed.3: 2012\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e1) IEC 61869-1 ed1.0: 2007; IEC 61869-2: ed1.0: 2012\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e1) IEC 61869-6: draft 2016; IEC 61869-10: draft 2016\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eESCT-RC150-3000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Current Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 - 5,000 Amp RMS (\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"\/pages\/contact-us\" title=\"Contact Faston Team\" style=\"color: #0000ff;\" target=\"_blank\"\u003eContact Us for Possible Replacement\u003c\/a\u003e\u003c\/span\u003e for wider range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSecondary Voltage (Sensitivity)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFrequency Measuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50-300kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5% from 25 to 5000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePhase Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCoil Diameter \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCoil Circumference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIntegrator to Coil Cable \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3M Twisted Pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMaximum Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1000V Reinforced insulation according to EN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eOperating Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-15°C to 65°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eStorage Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-45°C to 80°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation (50Hz, 1 min)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e7.4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOverload\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300,000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Stripped Wires\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\nUL, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1729061399\/Eastron%20Europe\/ESCT-RC_Catalogue.pdf\" title=\"Eastron Rogowski Coils\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet \u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e1) The Rogowski coil can measure any primary current as there is no saturation effect.\u003c\/p\u003e\n\u003cp\u003e2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (\u0026lt; 2 Watts)\u003c\/p\u003e\n\u003cp\u003e3) Frequency bandwidth and phase shift modeling schematic can be provided on request.\u003c\/p\u003e\n\u003cp\u003e4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)\u003c\/p\u003e\n\u003cp\u003e5) Considering a primary conductor of at least ? 15 mm, perpendicular and in contact with the Rogowski coil.\u003c\/p\u003e\n\u003cp\u003e6) Considering an external conductor of at least ? 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Eastron Europe","offers":[{"title":"Default Title","offer_id":41396178485382,"sku":"FE-ESCT-RC150-3000A","price":169.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/dm6a0252.jpg?v=1729061187"},{"product_id":"esct-rc240-10000a-rogowski-coil-75mm-diameter-85mv-ka-rated-for-10000-amp-recommended-3-meter-cable-length","title":"ESCT-RC240-10000A, Rogowski Coil, 240mm Diameter, 85mV\/kA Rated for 10000 Amp Recommended, 3 Meter Cable length","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eESCT-RC240-10000A, Rogowski Coil, 240mm Diameter, 85mV\/kA Rated for 10000 Amp Recommended, 3 Meter Cable length\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eFlexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and the secondary circuit (measurement). \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRated insulation voltage 1000 V Cat III PD2\u003c\/li\u003e\n\u003cli\u003eAccuracy Class 0.5 (IEC 61869-2)\u003c\/li\u003e\n\u003cli\u003eProtection degree IP67\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e3 m output cable (other lengths available see page 8)\u003c\/li\u003e\n\u003cli\u003eAmbient temperature 40 °C … +80 °C\u003c\/li\u003e\n\u003cli\u003eVery flexible and thin coil: 6.1 mm\u003c\/li\u003e\n\u003cli\u003eSlot for attaching the loop on the primary with a cable tie\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAn innovative patented clasp drastically reduces the positioning error near the closing\u003c\/li\u003e\n\u003cli\u003eInternal shield for enhanced measurement accuracy at low primary currents.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eThin, flexible, and light weight solution\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eVery low positioning error\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eQuick, non-intrusive and easy setup\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eA single sensor for a large current range without overload\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLess influenced by external fields\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAdaptable for a large range of cable diameters\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eMV\/LV substations on LV side: Transformer Condition Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003ePower metering: current measurement for active power calculation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eBuilding sub-metering: energy efficiency monitoring, consumption analysis and cost allocation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003ePower quality monitoring: electrical loads and distribution system equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eFault Detection, Isolation and Repair (FDIR): isolate the site of the fault\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eRemote Terminal Units (RTU)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003ePhasor Measurement Units (PMU)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eIEC 61010-1: 2010; IEC 61010-2-32 ed.3: 2012\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e1) IEC 61869-1 ed1.0: 2007; IEC 61869-2: ed1.0: 2012\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e1) IEC 61869-6: draft 2016; IEC 61869-10: draft 2016\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eESCT-RC240-10000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Current Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 - 5,000 Amp RMS (\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"\/pages\/contact-us\" title=\"Contact Faston Team\" style=\"color: #0000ff;\" target=\"_blank\"\u003eContact Us for Possible Replacement\u003c\/a\u003e\u003c\/span\u003e for wider range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSecondary Voltage (Sensitivity)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eFrequency Measuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50-300kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5% from 25 to 5000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePhase Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCoil Diameter \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCoil Circumference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIntegrator to Coil Cable \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3M Twisted Pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMaximum Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1000V Reinforced insulation according to EN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eOperating Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-15°C to 65°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eStorage Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-45°C to 80°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation (50Hz, 1 min)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e7.4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOverload\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300,000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Stripped Wires\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\nUL, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1729061399\/Eastron%20Europe\/ESCT-RC_Catalogue.pdf\" title=\"Eastron Rogowski Coils\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet \u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e1) The Rogowski coil can measure any primary current as there is no saturation effect.\u003c\/p\u003e\n\u003cp\u003e2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (\u0026lt; 2 Watts)\u003c\/p\u003e\n\u003cp\u003e3) Frequency bandwidth and phase shift modeling schematic can be provided on request.\u003c\/p\u003e\n\u003cp\u003e4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)\u003c\/p\u003e\n\u003cp\u003e5) Considering a primary conductor of at least ? 15 mm, perpendicular and in contact with the Rogowski coil.\u003c\/p\u003e\n\u003cp\u003e6) Considering an external conductor of at least ? 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Eastron Europe","offers":[{"title":"Default Title","offer_id":41396179239046,"sku":"FE-ESCT-RC240-10000A","price":219.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/dm6a0252.jpg?v=1729061187"},{"product_id":"c100n-100r-275v","title":"C100N+100R 275V, RC Snubber Network 275VAC, 100uF 100 Ohm","description":"\u003ch3\u003e\u003cspan style=\"color: #99b5e0;\"\u003e\u003cstrong\u003eC100N+100R 275V, RC Snubber Network 275VAC, 100uF 100 Ohm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eThese snubber neworks are suitable for transient supression in small contactors, bridge rectifers, or solid state relays switching AC or DC Loads. Easily connected or lugged to solid stage relay or power module terminals. See \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"\/collections\/schurter-line-filters\" title=\"EMC Filters\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eEMC filters\u003c\/a\u003e\u003c\/span\u003e, and \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"\/collections\/varistors\" title=\"Metal Oxide Varistors\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eMetal Oxide Varistors\u003c\/a\u003e\u003c\/span\u003e sections for additional supression components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eAs and added bonus, these Snubber Networks Improve the Power Factor of switched loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1733712952\/kemet_p409ce104m275ah101_apr22_xonlink_1.pdf\" title=\"KEMET RIFA C110N + 100R 275V Snubbers\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LeClanche","offers":[{"title":"Default Title","offer_id":41473904738438,"sku":"FE-C100N+100R 275V","price":6.5,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/leclanche-ssr-accessories-power-quality-snubber-capacitor-c100n-100r-snubber-network-250vac-100uf-100-ohm-13061708742790.jpg?v=1617936844"},{"product_id":"esct-rc200-6000a","title":"ESCT-RC200-6000A, Rogowski Coil, 200mm Diameter, 85mV\/kA Rated for 6000 Amp Recommended, 3 Meter Cable length","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eESCT-RC200-6000A, Rogowski Coil, 200mm Diameter, 85mV\/kA Rated for 6000 Amp Recommended, 3 Meter Cable length\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eFlexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and the secondary circuit (measurement). \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRated insulation voltage 1000 V Cat III PD2\u003c\/li\u003e\n\u003cli\u003eAccuracy Class 0.5 (IEC 61869-2)\u003c\/li\u003e\n\u003cli\u003eProtection degree IP67\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e3 m output cable (other lengths available see page 8)\u003c\/li\u003e\n\u003cli\u003eAmbient temperature 40 °C … +80 °C\u003c\/li\u003e\n\u003cli\u003eVery flexible and thin coil: 6.1 mm\u003c\/li\u003e\n\u003cli\u003eSlot for attaching the loop on the primary with a cable tie\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAn innovative patented clasp drastically reduces the positioning error near the closing\u003c\/li\u003e\n\u003cli\u003eInternal shield for enhanced measurement accuracy at low primary currents.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eThin, flexible, and light weight solution\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eVery low positioning error\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eQuick, non-intrusive and easy setup\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eA single sensor for a large current range without overload\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLess influenced by external fields\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAdaptable for a large range of cable diameters\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eMV\/LV substations on LV side: Transformer Condition Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003ePower metering: current measurement for active power calculation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eBuilding sub-metering: energy efficiency monitoring, consumption analysis and cost allocation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003ePower quality monitoring: electrical loads and distribution system equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eFault Detection, Isolation and Repair (FDIR): isolate the site of the fault\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eRemote Terminal Units (RTU)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003ePhasor Measurement Units (PMU)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eIEC 61010-1: 2010; IEC 61010-2-32 ed.3: 2012\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e1) IEC 61869-1 ed1.0: 2007; IEC 61869-2: ed1.0: 2012\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e1) IEC 61869-6: draft 2016; IEC 61869-10: draft 2016\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 99.9972%; height: 492.715px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 20px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 20px;\"\u003eESCT-RC200-6000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 20px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 20px;\"\u003eAC Current Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 39.1797px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 39.1797px;\"\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 39.1797px;\"\u003e0 - 5,000 Amp RMS (\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"\/pages\/contact-us\" title=\"Contact Faston Team\" style=\"color: #0000ff;\" target=\"_blank\"\u003eContact Us for Possible Replacement\u003c\/a\u003e\u003c\/span\u003e for wider range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 39.1797px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 39.1797px;\"\u003e\u003cstrong\u003eSecondary Voltage (Sensitivity)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 39.1797px;\"\u003e85mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 39.1797px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 39.1797px;\"\u003e\u003cstrong\u003eFrequency Measuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 39.1797px;\"\u003e50-300kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 20px;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 20px;\"\u003eSelf Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 20px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 20px;\"\u003e0.5% from 25 to 5000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 20px;\"\u003e\u003cstrong\u003ePhase Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 20px;\"\u003e\u0026lt; 0.004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 20px;\"\u003e\u003cstrong\u003eCoil Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 20px;\"\u003e20cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 20px;\"\u003e\u003cstrong\u003eCoil Circumference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 20px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 20px;\"\u003e\u003cb\u003eIntegrator to Coil Cable \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 20px;\"\u003e3M Twisted Pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 20px;\"\u003e\u003cb\u003eMaximum Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 20px;\"\u003e1000V Reinforced insulation according to EN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 20px;\"\u003e\u003cb\u003eOperating Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 20px;\"\u003e\u003cspan\u003e-15°C to 65°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 20px;\"\u003e\u003cb\u003eStorage Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 20px;\"\u003e\u003cspan\u003e-45°C to 80°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 20px;\"\u003e\u003cb\u003eIsolation (50Hz, 1 min)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 20px;\"\u003e7.4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 20px;\"\u003e\u003cstrong\u003eOverload\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 20px;\"\u003e300,000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 20px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 20px;\"\u003e\u003cspan\u003e2 Stripped Wires\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 20px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 20px;\"\u003e\u003cspan\u003e130g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 20px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 20px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 55.1758px;\"\u003e\n\u003ctd height=\"20\" style=\"width: 32.2757%; height: 55.1758px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3781%; height: 55.1758px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\nUL, ROHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1729061399\/Eastron%20Europe\/ESCT-RC_Catalogue.pdf\" title=\"Eastron Rogowski Coils\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet \u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cp\u003e1) The Rogowski coil can measure any primary current as there is no saturation effect.\u003c\/p\u003e\n\u003cp\u003e2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (\u0026lt; 2 Watts)\u003c\/p\u003e\n\u003cp\u003e3) Frequency bandwidth and phase shift modeling schematic can be provided on request.\u003c\/p\u003e\n\u003cp\u003e4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)\u003c\/p\u003e\n\u003cp\u003e5) Considering a primary conductor of at least ? 15 mm, perpendicular and in contact with the Rogowski coil.\u003c\/p\u003e\n\u003cp\u003e6) Considering an external conductor of at least ? 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Eastron Europe","offers":[{"title":"Default Title","offer_id":42941010477190,"sku":null,"price":199.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/dm6a0252.jpg?v=1729061187"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/collections\/Transorb.jpg?v=1604282249","url":"https:\/\/fastron.com.au\/collections\/transient-voltage-suppression-diodes.oembed?page=2","provider":"Fastron Electronics Store ","version":"1.0","type":"link"}