{"title":"Three Phase, 2 Leg Power Controllers","description":"\u003ch1\u003e\u003cspan style=\"color: #86b7df;\"\u003e\u003cstrong\u003eThree Phase, 2 Leg SCR Based Burst Fire (TAKT) Power Controllers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFastron have manufactured over 7000 Power controllers since we first introduced our SCR power controllers to the Australian market. Still 100% made in Australia, our Oztherm Power Controllers still prove to outlast all major competitors due to a rugged design built to withstand the harshest conditions in remote Australian regions. \u003c\/p\u003e\n\u003cp\u003eSuitable for Primary or secondary control, Fastron can also manufacture a secondary rectifier to suit, or produce a Controlled Bridge Rectifier in the same enclosure for DC applications. You can find some of our (7000+) custom made rectifer stacks \u003ca title=\"Fastron Stack Assemblies\" href=\"\/collections\/semiconductor-assemblies\" target=\"_blank\"\u003ehere\u003c\/a\u003e. \u003c\/p\u003e\n\u003cp\u003eWe offer customisations and repair services for all the control gear we manufacture.\u003c\/p\u003e\n\u003cp\u003eIn addition, Fastron proudly represents Advanced Energy (formerly AEG) the most cutting edge in peformance SCR Controllers and the original inventor of the Burst Fire SCR Control method. Their range includes Thyro S, Thyro A, Thyro AX, and Thyro PX Series SCR Power Controllers.  These controllers can operate in both Burst(TAKT) or Phase Angle(VAR) Firing Modes. These Controllers can operate in \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"SCR Burst Controllers\" href=\"\/collections\/burst-fire-power-controllers\" target=\"_blank\"\u003eburst fire\u003c\/a\u003e\u003c\/span\u003e mode even on the primary of the transformers with effectively zero DC offset. These Controllers are also avilable in Controlled Bridge Rectifier configrations for DC applications.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eFAQ's\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"faq-tabs\"\u003e\n\u003cdiv class=\"faq-item active\"\u003e\n\u003cdiv class=\"faq-question\"\u003e1. What is an SCR power controller and how does it regulate power?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eAn SCR power controller regulates power by controlling the phase angle or burst firing of voltage to a load. It uses silicon-controlled rectifiers (SCRs) to adjust the amount of power delivered, offering precise and efficient control. These controllers are ideal for applications where smooth and reliable power modulation is essential.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e2. Where can I buy a reliable SCR controller in Australia?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eYou can buy a reliable SCR controller in Australia from Fastron Electronics. With over 7000 units manufactured and a reputation for rugged, long-lasting design, Fastron offers Australian-made solutions as well as advanced models from global brands like Advanced Energy for a wide range of power control applications.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e3. What is the difference between an SCR power controller and a phase angle controller?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eAn SCR power controller can operate in multiple modes, including phase angle and burst firing. A phase angle controller specifically adjusts the conduction angle of each AC cycle, while an SCR controller may offer both control modes, providing greater flexibility for different load types and system requirements.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e4. How does a phase angle controller manage power delivery in AC systems?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eA phase angle controller manages power by adjusting the point in each AC cycle where the voltage is applied to the load. By controlling the conduction angle, it delivers a proportional amount of power, allowing smooth and gradual regulation. This is especially useful for resistive loads and processes that need fine control.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e5. Can I use SCR controllers for heating applications?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eYes, SCR controllers are ideal for heating applications. They offer precise temperature control by regulating the power delivered to electric heaters. Their smooth operation helps prevent power surges and wear on components, making them a preferred choice in both industrial and commercial heating systems.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e6. What are the main applications of SCR power controllers in industrial settings?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eSCR power controllers are widely used in industries for controlling electric heaters, motor speeds, lighting systems, and transformer primaries. Their ability to deliver stable and adjustable power makes them suitable for demanding environments, including manufacturing plants, process control systems, and remote operations.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e7. How does a phase angle controller improve the efficiency of electrical systems?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eA phase angle controller improves efficiency by delivering only the required amount of power to the load. This controlled delivery reduces energy waste, enhances system stability, and extends the life of electrical components. It's especially effective in systems requiring gradual power adjustment and minimal electrical noise.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e8. Are SCR controllers suitable for high-voltage applications?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eYes, SCR controllers are suitable for high-voltage applications, especially when designed with robust components and insulation. Fastron Electronics offers solutions that handle demanding conditions and voltages, making them ideal for industrial-scale power control across a variety of sectors.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e9. What is the role of SCR controllers in controlling motor speeds?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eSCR controllers help regulate motor speeds by controlling the voltage or current supplied to the motor. This method ensures smooth acceleration and deceleration, minimising mechanical stress. They are particularly useful in systems where variable speed control is essential for performance and energy efficiency.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e10. How do I install an SCR power controller in my electrical circuit?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eTo install an SCR power controller, mount it securely in the control panel, connect it to the appropriate power and load terminals, and configure it based on your application. Professional installation is recommended to ensure proper safety, compatibility, and performance, especially in high-voltage environments.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e11. Can SCR controllers be used in conjunction with other power control systems?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eYes, SCR controllers can be integrated with other power control systems such as PLCs, sensors, and feedback loops. This allows for advanced automation and more precise regulation in complex industrial processes, enhancing overall system efficiency and control flexibility.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e12. Do phase angle controllers provide smooth control of power?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eYes, phase angle controllers provide smooth and continuous control of power delivery. By adjusting the conduction phase within each AC cycle, they avoid sudden surges and provide fine-tuned power adjustments, which is critical in sensitive applications like heating and lighting systems.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e13. What is the maximum current and voltage capacity of your SCR controllers?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eThe SCR controllers available from Fastron Electronics come in various current and voltage capacities to suit different applications. Custom configurations and higher-rated models are available on request to support industrial systems with more demanding power requirements.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e14. Are SCR power controllers available for both AC and DC applications?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eYes, SCR power controllers are available for both AC and DC applications depending on the configuration. Fastron Electronics provides flexible control solutions for a range of use cases, including transformer primaries, DC heating, and motor control.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e15. Do your SCR controllers comply with Australian electrical safety standards?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eYes, SCR controllers supplied by Fastron Electronics are designed and manufactured to comply with relevant Australian electrical safety standards, ensuring safe and reliable operation across industrial and commercial environments.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","products":[{"product_id":"thyro-a-2a-400-16-h3","title":"Thyro-A-2A-400-16-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 16Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-16-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 16Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-16-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477001965702,"sku":"FE-Thyro A 2A 400-16 H3","price":1266.46,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_4757eaf5-aef2-45cd-9a47-c26268694929.jpg?v=1759459008"},{"product_id":"thyro-a-2a-400-30-h3","title":"Thyro-A-2A-400-30-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 30Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-30-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 30Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-30-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477001998470,"sku":"FE-Thyro A 2A 400-30 H3","price":1657.58,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_5fe37b89-b8e1-411d-ae2d-4ffb4673f5df.jpg?v=1759459012"},{"product_id":"thyro-a-2a-400-45-h3","title":"Thyro-A-2A-400-45-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 45Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-45-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 45Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-45-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477002195078,"sku":"FE-Thyro A 2A 400-45 H3","price":1799.27,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_7a2e7b36-a2f8-4128-80c0-5f47fe964ce3.jpg?v=1759459015"},{"product_id":"thyro-a-2a-400-60-h3","title":"Thyro-A-2A-400-60-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 60Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-60-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 60Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-60-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477002227846,"sku":"FE-Thyro A 2A 400-60 H3","price":2148.32,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_b009b763-ddf3-4202-b6d5-ef12ec6d0668.jpg?v=1759459019"},{"product_id":"thyro-a-2a-400-100-h3","title":"Thyro-A-2A-400-100-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 100Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-100-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 100Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-100-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477002424454,"sku":"FE-Thyro A 2A 400-100 H3","price":2428.4,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_204c9601-d20b-4369-9f14-3e543c68e8d7.jpg?v=1759459022"},{"product_id":"thyro-a-2a-400-130-h3","title":"Thyro-A-2A-400-130-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 130Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-130-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 130Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-130-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477002457222,"sku":"FE-Thyro A 2A 400-130 H3","price":2542.91,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_99384fa3-a955-4e9c-a3d1-19bfdebd28eb.jpg?v=1759459025"},{"product_id":"thyro-a-2a-400-170-h3","title":"Thyro-A-2A-400-170-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 170Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-170-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 170Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-170-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477002489990,"sku":"FE-Thyro A 2A 400-170 H3","price":3003.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_9fdc51e6-fd88-4ca6-823b-f82a0420f3d5.jpg?v=1759459029"},{"product_id":"thyro-a-2a-400-280-h3","title":"Thyro-A-2A-400-280-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 280Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-280-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 280Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-280-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477002522758,"sku":"FE-Thyro A 2A 400-280 H3","price":4156.9,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_d48ecb61-591d-4c26-9ab4-629766554f67.jpg?v=1759459032"},{"product_id":"thyro-a-2a-400-350-h3","title":"Thyro-A-2A-400-350-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 350Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-350-H3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 350Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control only\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-350-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477002555526,"sku":"FE-Thyro A 2A 400-350 H3","price":5045.7,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_82acf69d-af4f-4dd9-bcc8-cc3c9bec3302.jpg?v=1759459036"},{"product_id":"thyro-a-2a-400-16-hrl3","title":"Thyro-A-2A-400-16-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 16Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-16-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 16Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-16-HRL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477002588294,"sku":"FE-Thyro A 2A 400-16 HRL3","price":1765.93,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_381d4b2a-94e3-4acd-9f63-92fbb9b07ab3.jpg?v=1759459039"},{"product_id":"thyro-a-2a-400-30-hrl3","title":"Thyro-A-2A-400-30-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 30Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-30-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 30Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-30-HRL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477002621062,"sku":"FE-Thyro A 2A 400-30 HRL3","price":1845.61,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_fe599ac6-25c9-4b1b-b881-0e1c0fa0f4d6.jpg?v=1759459043"},{"product_id":"thyro-a-2a-400-45-hrl3","title":"Thyro-A-2A-400-45-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 45Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-45-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 45Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-45-HRL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477002653830,"sku":"FE-Thyro A 2A 400-45 HRL3","price":2272.22,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_2b8565f1-5fbd-49a5-a1ed-b2368462e39f.jpg?v=1759459046"},{"product_id":"thyro-a-2a-400-60-hrl3","title":"Thyro-A-2A-400-60-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 60Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-60-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 60Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-60-HRL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477002686598,"sku":"FE-Thyro A 2A 400-60 HRL3","price":2636.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_3d48bafb-550a-40b9-ba63-1ec4bd1c74e9.jpg?v=1759459050"},{"product_id":"thyro-a-2a-400-100-hrl3","title":"Thyro-A-2A-400-100-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 100Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-100-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 100Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-100-HRL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477002752134,"sku":"FE-Thyro A 2A 400-100 HRL3","price":3085.6,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_bd8dae13-6a8d-4174-b23e-ada4971749c2.jpg?v=1759459053"},{"product_id":"thyro-a-2a-400-130-hrl3","title":"Thyro-A-2A-400-130-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 130Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-130-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 130Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-130-HRL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477002784902,"sku":"FE-Thyro A 2A 400-130 HRL3","price":3499.13,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_b571218b-fe62-4204-946b-ad061534f525.jpg?v=1759459056"},{"product_id":"thyro-a-2a-400-170-hrl3","title":"Thyro-A-2A-400-170-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 170Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-170-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 170Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-170-HRL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477002981510,"sku":"FE-Thyro A 2A 400-170 HRL3","price":3661.9,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_5d373532-9729-410f-9b96-d887ea6886a3.jpg?v=1759459060"},{"product_id":"thyro-a-2a-400-280-hrl3","title":"Thyro-A-2A-400-280-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 280Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-280-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 280Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-280-HRL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477003014278,"sku":"FE-Thyro A 2A 400-280 HRL3","price":5242.6,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_228ca134-4b41-45b9-a954-d932587351b3.jpg?v=1759459064"},{"product_id":"thyro-a-2a-400-350-hrl3","title":"Thyro-A-2A-400-350-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 350Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-350-HRL3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 350Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-350-HRL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477003047046,"sku":"FE-Thyro A 2A 400-350 HRL3","price":6220.5,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_9fd3fdf2-a2de-4460-bd6e-86433e648131.jpg?v=1759459067"},{"product_id":"thyro-a-2a-400-16-hrlp3","title":"Thyro-A-2A-400-16-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 16Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-16-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 16Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-16-HRLP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477003079814,"sku":"FE-Thyro A 2A 400-16 HRLP3","price":2135.1,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_2797818f-0a7e-4692-90df-abe88ec6eceb.jpg?v=1759459071"},{"product_id":"thyro-a-2a-400-30-hrlp3","title":"Thyro-A-2A-400-30-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 30Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-30-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 30Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-30-HRLP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477003112582,"sku":"FE-Thyro A 2A 400-30 HRLP3","price":2680.7,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_95e2dd0c-8a3f-44eb-9a52-29b9df2eeb12.jpg?v=1759459074"},{"product_id":"thyro-a-2a-400-45-hrlp3","title":"Thyro-A-2A-400-45-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 45Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-45-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 45Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-45-HRLP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477003145350,"sku":"FE-Thyro A 2A 400-45 HRLP3","price":2981.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_3ff89c7b-a078-4fa4-9d80-f10e0338e7ee.jpg?v=1759459078"},{"product_id":"thyro-a-2a-400-60-hrlp3","title":"Thyro-A-2A-400-60-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 60Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-60-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 60Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-60-HRLP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477003178118,"sku":"FE-Thyro A 2A 400-60 HRLP3","price":3298.54,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_858b64a2-fc27-4adc-a3fa-74c168d4496d.jpg?v=1759459081"},{"product_id":"thyro-a-2a-400-100-hrlp3","title":"Thyro-A-2A-400-100-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 100Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-100-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 100Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-100-HRLP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477003243654,"sku":"FE-Thyro A 2A 400-100 HRLP3","price":3682.8,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_af18e297-828f-41d8-b91d-103c4996b6b2.jpg?v=1759459084"},{"product_id":"thyro-a-2a-400-130-hrlp3","title":"Thyro-A-2A-400-130-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 130Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-130-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 130Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-130-HRLP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A User Manual\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"2 Leg Control Applicaitons Blog Article\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" style=\"color: #2b00ff;\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installtion Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" title=\"Ethernet IP Setup Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477003276422,"sku":"FE-Thyro A 2A 400-130 HRLP3","price":4107.4,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_a1a96553-751f-4c41-8650-d40efb517e05.jpg?v=1759459088"},{"product_id":"thyro-a-2a-400-170-hrlp3","title":"Thyro-A-2A-400-170-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 170Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-170-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 170Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-170-HRLP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477003636870,"sku":"FE-Thyro A 2A 400-170 HRLP3","price":4519.9,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_fee8ad64-28bb-4b20-b187-85588dfca521.jpg?v=1759459091"},{"product_id":"thyro-a-2a-400-280-hrlp3","title":"Thyro-A-2A-400-280-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 280Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-280-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 280Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-280-HRLP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477003669638,"sku":"FE-Thyro A 2A 400-280 HRLP3","price":6155.6,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_487a02bd-2aff-48e9-bfe5-9f389e3766ef.jpg?v=1759459095"},{"product_id":"thyro-a-2a-400-350-hrlp3","title":"Thyro-A-2A-400-350-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 350Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-2A-400-350-HRLP3, Thyro-A-2A-Series 2 Leg 3 Phase SCR Controller 350Amp 400VAC +10\/-57% Burst(TAKT) Fire Mode, Economical Firing Mode, Voltage Control, Current Limit, Power Limit Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-2A-400-350-HRLP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-57% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477003702406,"sku":"FE-Thyro A 2A 400-350 HRLP3","price":7229.2,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_c631be56-14b2-4531-84f9-cd4bffd586a8.jpg?v=1759459099"},{"product_id":"t6-2-4-60z","title":"T6 Series Low Cost 3 Phase, 2 Leg SCR Burst Controller, 400VAC with In built Fuses, 40 Amps per Phase @ 50 Deg C","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFastron T6-2-4-75Z (60), 3 Phase, 2 Leg SCR Burst Controller, 400VAC with In built Fuses, 40 Amps per Phase @ 50 Deg C\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePhase Angle, Distributed Burst, and Time Proportional Burst Control Functions\u003c\/li\u003e\n\u003cli\u003eMade in China, Low cost\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e3 Phase, or Single Phase, Angle\/Burst Controller\u003c\/li\u003e\n\u003cli\u003e4-20mA\/0-10V\/1-5V\/5K POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRS485 Modbus RTU as standard\u003c\/li\u003e\n\u003cli\u003e2 x Analogue Outputs as standard\u003c\/li\u003e\n\u003cli\u003eLimit POT input for output limitation\u003c\/li\u003e\n\u003cli\u003eC\/O Alarm Contacts\u003c\/li\u003e\n\u003cli\u003eStart\/Stop Run Feature\u003c\/li\u003e\n\u003cli\u003eFully enclosed IP20\u003c\/li\u003e\n\u003cli\u003ePhase Angle or Burst switching\u003c\/li\u003e\n\u003cli\u003eAluminium Frame\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003eHVAC Heaters\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eControlled Power Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heatsing\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for HVAC or Industrial Environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\n\u003cspan style=\"color: #8bbbe7;\"\u003e\u003cstrong\u003eFastron Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eT6-2-4-75Z (60),\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eST6-2-4-40Z (32),T6-2-4-50Z (40)\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003cspan\u003e°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Phase, 2 Leg, AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20mA\/0-10V\/0-5V\/5K POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 Amps Per Phase @ 50 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDerating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2% per 1 Deg C (approx)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAlarms\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x C\/O Relay Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eSpecial Feature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAnalogue Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x Programmable Outputs (3 Phase), 1 x Programmable Output (Single Phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eComms\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eRS485 Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSwitching Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400VAC +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eSupply Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e230VAC +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eSoft Start\/Stop\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4kg (6kg Packed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"FTPS Series Controller\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1614895544\/Fastron%20Stuff\/Fastron_T6-SCR_User_Manual.pdf\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Fastron Electronics","offers":[{"title":"Default Title","offer_id":42477051478150,"sku":"FE-T6-2-4-50Z","price":795.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/2LegT6_decal.jpg?v=1759462390"},{"product_id":"t6-2-4-40z","title":"T6 Series Low Cost 3 Phase, 2 Leg SCR Burst Controller, 400VAC with In built Fuses, 32 Amps per Phase @ 50 Deg C","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFastron T6-2-4-75Z (60), 3 Phase, 2 Leg SCR Burst Controller, 400VAC with In built Fuses, 32 Amps per Phase @ 50 Deg C\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePhase Angle, Distributed Burst, and Time Proportional Burst Control Functions\u003c\/li\u003e\n\u003cli\u003eMade in China, Low cost\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e3 Phase, or Single Phase, Angle\/Burst Controller\u003c\/li\u003e\n\u003cli\u003e4-20mA\/0-10V\/1-5V\/5K POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRS485 Modbus RTU as standard\u003c\/li\u003e\n\u003cli\u003e2 x Analogue Outputs as standard\u003c\/li\u003e\n\u003cli\u003eLimit POT input for output limitation\u003c\/li\u003e\n\u003cli\u003eC\/O Alarm Contacts\u003c\/li\u003e\n\u003cli\u003eStart\/Stop Run Feature\u003c\/li\u003e\n\u003cli\u003eFully enclosed IP20\u003c\/li\u003e\n\u003cli\u003ePhase Angle or Burst switching\u003c\/li\u003e\n\u003cli\u003eAluminium Frame\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003eHVAC Heaters\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eControlled Power Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heatsing\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for HVAC or Industrial Environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\n\u003cspan style=\"color: #8bbbe7;\"\u003e\u003cstrong\u003eFastron Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eT6-2-4-75Z (60),\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eST6-2-4-40Z (32),T6-2-4-50Z (40)\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003cspan\u003e°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Phase, 2 Leg, AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20mA\/0-10V\/0-5V\/5K POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 Amps Per Phase @ 50 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDerating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2% per 1 Deg C (approx)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAlarms\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x C\/O Relay Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eSpecial Feature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAnalogue Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x Programmable Outputs (3 Phase), 1 x Programmable Output (Single Phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eComms\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eRS485 Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSwitching Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400VAC +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eSupply Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e230VAC +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eSoft Start\/Stop\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4kg (6kg Packed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"FTPS Series Controller\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1614895544\/Fastron%20Stuff\/Fastron_T6-SCR_User_Manual.pdf\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Fastron Electronics","offers":[{"title":"Default Title","offer_id":42477051510918,"sku":"FE-T6-2-4-40Z","price":695.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/2LegT6_decal_c3906751-d81e-4caf-8fcc-7df89578baa9.jpg?v=1759462391"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/collections\/Thyro_A_ECO_2_phase.jpg?v=1759455736","url":"https:\/\/fastron.com.au\/collections\/three-phase-2-leg-power-controllers.oembed?page=3","provider":"Fastron Electronics Store ","version":"1.0","type":"link"}