{"title":"Phase Angle Power Controllers SCR Based","description":"\u003ch1\u003e\u003cspan style=\"color: #86b7df;\"\u003e\u003cstrong\u003eSCR Based Phase Angle Power Controllers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFastron have manufactured over 7000 Power controllers since we first introduced our SCR power controllers to the Australian market. Still 100% made in Australia, our Oztherm Power Controllers still prove to outlast all major competitors due to a rugged design built to withstand the harshest conditions in remote Australian regions. \u003c\/p\u003e\n\u003cp\u003eSuitable for Primary or secondary control, Fastron can also manufacture a secondary rectifer to suit. You can find some of our (7000+) custom made rectifer stacks \u003ca href=\"\/collections\/semiconductor-assemblies\" title=\"Fastron Stack Assemblies\" target=\"_blank\"\u003ehere\u003c\/a\u003e. \u003c\/p\u003e\n\u003cp\u003eWe offer customisations and repair services for all the control gear we manufacture.\u003c\/p\u003e\n\u003cp\u003eIn addition, Fastron proudly represents Advanced Energy (formerly AEG) the most cutting edge in peformance SCR Controllers and the original inventor of the Burst Fire SCR Control method. Their range includes Thyro S, Thyro A, Thyro AX, and Thyro PX Series SCR Power Controllers.  These controllers can operate in both Burst(TAKT) or Phase Angle(VAR) Firing Modes. These Controllers can operate in \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"\/collections\/burst-fire-power-controllers\" title=\"SCR Burst Controllers\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eburst fire\u003c\/a\u003e\u003c\/span\u003e mode even on the primary of the transformers with effectively zero DC offset.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eFAQ's\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"faq-tabs\"\u003e\n\u003cdiv class=\"faq-item active\"\u003e\n\u003cdiv class=\"faq-question\"\u003e1. What is an SCR power controller and how does it regulate power?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eAn SCR power controller regulates power by controlling the phase angle or burst firing of voltage to a load. It uses silicon-controlled rectifiers (SCRs) to adjust the amount of power delivered, offering precise and efficient control. These controllers are ideal for applications where smooth and reliable power modulation is essential.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e2. Where can I buy a reliable SCR controller in Australia?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eYou can buy a reliable SCR controller in Australia from Fastron Electronics. With over 7000 units manufactured and a reputation for rugged, long-lasting design, Fastron offers Australian-made solutions as well as advanced models from global brands like Advanced Energy for a wide range of power control applications.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e3. What is the difference between an SCR power controller and a phase angle controller?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eAn SCR power controller can operate in multiple modes, including phase angle and burst firing. A phase angle controller specifically adjusts the conduction angle of each AC cycle, while an SCR controller may offer both control modes, providing greater flexibility for different load types and system requirements.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e4. How does a phase angle controller manage power delivery in AC systems?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eA phase angle controller manages power by adjusting the point in each AC cycle where the voltage is applied to the load. By controlling the conduction angle, it delivers a proportional amount of power, allowing smooth and gradual regulation. This is especially useful for resistive loads and processes that need fine control.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e5. Can I use SCR controllers for heating applications?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eYes, SCR controllers are ideal for heating applications. They offer precise temperature control by regulating the power delivered to electric heaters. Their smooth operation helps prevent power surges and wear on components, making them a preferred choice in both industrial and commercial heating systems.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e6. What are the main applications of SCR power controllers in industrial settings?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eSCR power controllers are widely used in industries for controlling electric heaters, motor speeds, lighting systems, and transformer primaries. Their ability to deliver stable and adjustable power makes them suitable for demanding environments, including manufacturing plants, process control systems, and remote operations.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e7. How does a phase angle controller improve the efficiency of electrical systems?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eA phase angle controller improves efficiency by delivering only the required amount of power to the load. This controlled delivery reduces energy waste, enhances system stability, and extends the life of electrical components. It's especially effective in systems requiring gradual power adjustment and minimal electrical noise.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e8. Are SCR controllers suitable for high-voltage applications?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eYes, SCR controllers are suitable for high-voltage applications, especially when designed with robust components and insulation. Fastron Electronics offers solutions that handle demanding conditions and voltages, making them ideal for industrial-scale power control across a variety of sectors.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e9. What is the role of SCR controllers in controlling motor speeds?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eSCR controllers help regulate motor speeds by controlling the voltage or current supplied to the motor. This method ensures smooth acceleration and deceleration, minimising mechanical stress. They are particularly useful in systems where variable speed control is essential for performance and energy efficiency.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e10. How do I install an SCR power controller in my electrical circuit?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eTo install an SCR power controller, mount it securely in the control panel, connect it to the appropriate power and load terminals, and configure it based on your application. Professional installation is recommended to ensure proper safety, compatibility, and performance, especially in high-voltage environments.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e11. Can SCR controllers be used in conjunction with other power control systems?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eYes, SCR controllers can be integrated with other power control systems such as PLCs, sensors, and feedback loops. This allows for advanced automation and more precise regulation in complex industrial processes, enhancing overall system efficiency and control flexibility.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e12. Do phase angle controllers provide smooth control of power?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eYes, phase angle controllers provide smooth and continuous control of power delivery. By adjusting the conduction phase within each AC cycle, they avoid sudden surges and provide fine-tuned power adjustments, which is critical in sensitive applications like heating and lighting systems.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e13. What is the maximum current and voltage capacity of your SCR controllers?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eThe SCR controllers available from Fastron Electronics come in various current and voltage capacities to suit different applications. Custom configurations and higher-rated models are available on request to support industrial systems with more demanding power requirements.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e14. Are SCR power controllers available for both AC and DC applications?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eYes, SCR power controllers are available for both AC and DC applications depending on the configuration. Fastron Electronics provides flexible control solutions for a range of use cases, including transformer primaries, DC heating, and motor control.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cdiv class=\"faq-question\"\u003e15. Do your SCR controllers comply with Australian electrical safety standards?\u003c\/div\u003e\n\u003cdiv class=\"faq-answer\"\u003eYes, SCR controllers supplied by Fastron Electronics are designed and manufactured to comply with relevant Australian electrical safety standards, ensuring safe and reliable operation across industrial and commercial environments.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","products":[{"product_id":"f311-2-n-a-cards-only","title":"Phase Angle Controller, F311 Series Single Phase 240VAC, Cards Only","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eOztherm F311 Series Single Phase SCR Phase Angle Controller, Card Only\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e100% Australian Made\u003c\/li\u003e\n\u003cli\u003eSingle Phase, Phase Angle Controller or AC Soft Starter\u003c\/li\u003e\n\u003cli\u003e4-20mA, 0-5V, 0-10V or POT input Proportional Phase Control\u003c\/li\u003e\n\u003cli\u003ePhase angle switching\u003c\/li\u003e\n\u003cli\u003eCards Only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Rectifers\u003c\/li\u003e\n\u003cli\u003eControlled Power Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003cli\u003eSheet Metal Welding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAvailable Options\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eVoltage Regulation AC (A)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Limit and Trip AC (C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Constant Current AC (CC)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003ePower Limit (PW)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoose Semiconductor Fuses (F)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternal Semiconductor Fuses (FI)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThermal Overload Protection (T)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSpecial Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/pages\/contact-us\" target=\"_blank\" title=\"Contact Fastron\" rel=\"noopener noreferrer\"\u003e\u003cspan\u003eContact Us for Possible Replacement\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003efor customised features\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eOztherm Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eF330 Series 3 Phase, Phase Angle Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eRated Operationg Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003cspan\u003e°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Phase AC Swtich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20mA, 0-5V, 0-10V, 10K POT (4-20mA default calibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 - 150 Amps Per Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eSpecial Feature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(Optional) Current Limit \u0026amp; Trip AC, Current Control AC, Voltage Regulation AC, Power Limit, Thermal Overload Protection, Fuses \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190-265VAC +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1-20mS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 28kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1539221128\/Fastron%20Stuff\/F-330_Brochure.pdf\" target=\"_blank\" title=\"F330 3 Phase, Phase Controller Brochure\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003eF311 Brochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581300219\/Fastron%20Stuff\/F311_Installation_Commissioning_Manual.pdf\" target=\"_blank\" title=\"F311 User Manual\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003eF311 Installation and Commissioning Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/blogs\/power-controllers\/fastron-oztherm-power-controller-series\" target=\"_blank\" title=\"Blog Calibration Procedure\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003eCalibration Procedure Blog - New\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581301381\/Fastron%20Stuff\/F311_Calibration_Procedures.pdf\" target=\"_blank\" title=\"F311 Calibration Procedure\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003eCalibration Procedure PDF\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581300480\/Fastron%20Stuff\/F311-Thyristor-DWG-1024-A1-ISS-01.pdf\" target=\"_blank\" title=\"SCR Wiring\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003eThyristor Wiring Diagrams - New\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581300480\/Fastron%20Stuff\/F311_Options-DWG-1024-A2-ISS-01.pdf\" target=\"_blank\" title=\"Control Wiring\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003eControl Wiring Diagrams - New\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eCustomised models\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/pages\/oztherm-phase-angle-controller-special-sp-builds\" target=\"_blank\" title=\"Special Builds\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003eCustomised models list\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/pages\/contact-us\" target=\"_blank\" title=\"Contact Fastron\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003eContact Us for Possible Replacement\u003c\/a\u003e\u003c\/span\u003e for customised features not listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Oztherm","offers":[{"title":"F311 Controller Spare \/ None \/ None","offer_id":17712101687411,"sku":"FE-F311-2-N\/A-GO","price":815.0,"currency_code":"AUD","in_stock":true},{"title":"F311 Controller Spare \/ (F) Loose Semiconductor Fuse \/ None","offer_id":29555237781619,"sku":"FE-F311-2-N\/A-F-GO","price":891.0,"currency_code":"AUD","in_stock":true},{"title":"F311 Controller Spare \/ None \/ (C) Current Limit and Trip AC","offer_id":29555237814387,"sku":"FE-F311-2-N\/A-C-GO","price":1002.0,"currency_code":"AUD","in_stock":true},{"title":"F311 Controller Spare \/ None \/ (CC) Current Control","offer_id":29555237847155,"sku":"FE-F311-2-N\/A-CC-GO","price":1002.0,"currency_code":"AUD","in_stock":true},{"title":"F311 Controller Spare \/ (F) Loose Semiconductor Fuse \/ (C) Current Limit and Trip AC","offer_id":29555237879923,"sku":"FE-F311-2-N\/A-C-F-GO","price":1079.0,"currency_code":"AUD","in_stock":true},{"title":"F311 Controller Spare \/ (F) Loose Semiconductor Fuse \/ (C) Current Limit and Trip AC + (A) Voltage Regulation","offer_id":29555237912691,"sku":"FE-F311-2-N\/A-A-C-F-GO","price":1215.0,"currency_code":"AUD","in_stock":true},{"title":"F311 Controller Spare \/ (F) Loose Semiconductor Fuse \/ (C) + (A) + (PW) Power Limit","offer_id":29555237945459,"sku":"FE-F311-2-N\/A-A-C-PW-F-GO","price":1344.0,"currency_code":"AUD","in_stock":true},{"title":"1M w\/ BOTTOM spade connections \/ None \/ None","offer_id":29555237978227,"sku":"FE-F311-2-N\/A-GB","price":815.0,"currency_code":"AUD","in_stock":true},{"title":"1M w\/ BOTTOM spade connections \/ (F) Loose Semiconductor Fuse \/ None","offer_id":29555238010995,"sku":"FE-F311-2-N\/A-F-GB","price":891.0,"currency_code":"AUD","in_stock":true},{"title":"1M w\/ BOTTOM spade connections \/ None \/ (C) Current Limit and Trip AC","offer_id":29555238043763,"sku":"FE-F311-2-N\/A-C-GB","price":1002.0,"currency_code":"AUD","in_stock":true},{"title":"1M w\/ BOTTOM spade connections \/ None \/ (CC) Current Control","offer_id":29555238076531,"sku":"FE-F311-2-N\/A-CC-GB","price":1002.0,"currency_code":"AUD","in_stock":true},{"title":"1M w\/ BOTTOM spade connections \/ (F) Loose Semiconductor Fuse \/ (C) Current Limit and Trip AC","offer_id":29555238109299,"sku":"FE-F311-2-N\/A-C-F-GB","price":1079.0,"currency_code":"AUD","in_stock":true},{"title":"1M w\/ BOTTOM spade connections \/ (F) Loose Semiconductor Fuse \/ (C) Current Limit and Trip AC + (A) Voltage Regulation","offer_id":29555238142067,"sku":"FE-F311-2-N\/A-A-C-F-GB","price":1215.0,"currency_code":"AUD","in_stock":true},{"title":"1M w\/ BOTTOM spade connections \/ (F) Loose Semiconductor Fuse \/ (C) + (A) + (PW) Power Limit","offer_id":29555238174835,"sku":"FE-F311-2-N\/A-A-C-PW-F-GB","price":1344.0,"currency_code":"AUD","in_stock":true},{"title":"1M w\/ TOP spade connections \/ None \/ None","offer_id":29555238207603,"sku":"FE-F311-2-N\/A-GG","price":815.0,"currency_code":"AUD","in_stock":true},{"title":"1M w\/ TOP spade connections \/ (F) Loose Semiconductor Fuse \/ None","offer_id":29555238240371,"sku":"FE-F311-2-N\/A-F-GG","price":891.0,"currency_code":"AUD","in_stock":true},{"title":"1M w\/ TOP spade connections \/ None \/ (C) Current Limit and Trip AC","offer_id":29555238273139,"sku":"FE-F311-2-N\/A-C-GG","price":1002.0,"currency_code":"AUD","in_stock":true},{"title":"1M w\/ TOP spade connections \/ None \/ (CC) Current Control","offer_id":29555238305907,"sku":"FE-F311-2-N\/A-CC-GG","price":1002.0,"currency_code":"AUD","in_stock":true},{"title":"1M w\/ TOP spade connections \/ (F) Loose Semiconductor Fuse \/ (C) Current Limit and Trip AC","offer_id":29555238338675,"sku":"FE-F311-2-N\/A-C-F-GG","price":1079.0,"currency_code":"AUD","in_stock":true},{"title":"1M w\/ TOP spade connections \/ (F) Loose Semiconductor Fuse \/ (C) Current Limit and Trip AC + (A) Voltage Regulation","offer_id":29555238371443,"sku":"FE-F311-2-N\/A-A-C-F-GG","price":1215.0,"currency_code":"AUD","in_stock":true},{"title":"1M w\/ TOP spade connections \/ (F) Loose Semiconductor Fuse \/ (C) + (A) + (PW) Power Limit","offer_id":29555238404211,"sku":"FE-F311-2-N\/A-A-C-PW-F-GG","price":1344.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/oztherm-single-phase-scr-phase-angle-power-controller-cards-only-phase-angle-controller-f311-series-single-phase-240vac-cards-only-6277671485555.jpg?v=1610355692"},{"product_id":"f330-4-n-a-cards-only","title":"Phase Angle Controller, F330 Series 3 Phase, Cards Only","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eOztherm F330 Series 3 Phase SCR Phase Angle Controller Spare Card Set, Can Replace Novatherm C3000 \u0026amp; C3000A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e100% Australian Made\u003c\/li\u003e\n\u003cli\u003e3 Phase, Phase Angle Controller or DC Soft Starter\u003c\/li\u003e\n\u003cli\u003e4-20mA, 0-5V, 0-10V or POT input Proportional Phase Control\u003c\/li\u003e\n\u003cli\u003eFully enclosed IP20\u003c\/li\u003e\n\u003cli\u003ePhase angle switching\u003c\/li\u003e\n\u003cli\u003eAluminium Frame\u003c\/li\u003e\n\u003cli\u003eRemovable perspex Cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter\u003c\/li\u003e\n\u003cli\u003eControlled Power Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003cli\u003eSheet Metal Welding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAvailable Options\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eVoltage Regulation AC (A)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Limit and Trip AC (C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Limit and Trip DC (CE)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Constant Current AC(CC)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Constant Current DC(CCE)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003ePower Limit (PW)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003ePhase Loss Alarm\/Dispable (PH)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoose Semiconductor Fuses (F)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eInternal Semiconductor\u003cspan\u003e \u003c\/span\u003eFuses (FI)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eThermal Overlad Protection (T)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSpecial Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003ca title=\"Contact Fastron\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/pages\/contact-us\" target=\"_blank\"\u003e\u003cspan\u003eContact Us for Possible Replacement\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e for customised features\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eOztherm Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eF330 Series 3 Phase, Phase Angle Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eRated Operationg Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003cspan\u003e°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Phase AC Swtich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20mA, 0-5V, 0-10V, 10K POT (4-20mA default calibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eSpecial Feature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(Optional) Current Limit \u0026amp; Trip AC or DC, Current Control AC or DC, Voltage Regulation AC, Power Limit, Phase Loss Alarm, Thermal Overload Protection, Fuses \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-440VAC +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1-20mS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 10kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eBrochure\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"F330 Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1539221128\/Fastron%20Stuff\/F-330_Brochure.pdf\"\u003eF330 Brochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\"\u003e\u003ca title=\"F330 User Manual\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581319211\/Fastron%20Stuff\/F330_Installation_Commissioning_Manual.pdf\" target=\"_blank\"\u003eInstallation and Commissioning Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca title=\"SCR Wiring 3 x AC switch\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581302965\/Fastron%20Stuff\/F330_Thyristor_Wiring_DWG-1010-A2-ISS-01.pdf\" target=\"_blank\"\u003eStandard Thyristor Wiring Diagram\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Control Card Wiring Diagram\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581302965\/Fastron%20Stuff\/F330_Control_Wiring_Complete_DWG-1084-A1..2-ISS-01.pdf\" target=\"_blank\"\u003eControl Card Wiring Diagram F311A1\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"New CCE Option Card wiring\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581302965\/Fastron%20Stuff\/F330_PCB1019-XX_Control_Wiring_Complete-DWG-1084A-A1..2-ISS-01.pdf\" target=\"_blank\"\u003eNew CCE option PCB1019-XX Wiring Diagram\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Bridge SCR Wiring 3 Phase\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581302965\/Fastron%20Stuff\/F330_Bridge_Thyritor_Wiring_DWG-1010-A1-ISS-01.pdf\" target=\"_blank\"\u003eBridge Output Thyristor Wiring Diagram\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Tranformer Primary Wiring\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581302965\/Fastron%20Stuff\/F330-Primary_Transformer_Wiring_DWG-1010-A4-ISS-01.pdf\" target=\"_blank\"\u003ePrimary Transformer Wiring Diagram\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Star Delta Wiring Diagram\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581302965\/Fastron%20Stuff\/SP100_Star_Delta_Dual_Bridge_Wiring_DWG-1010-A3-ISS-01.pdf\" target=\"_blank\"\u003eStart Delta Wiring Diagram\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"F330 Calibration Procedure\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/blogs\/power-controllers\/fastron-oztherm-power-controller-f330-series-calibration-procedure\" target=\"_blank\"\u003eCalibration Procedure Blog\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"F330 Calibration PDF Download\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581321085\/Fastron%20Stuff\/F330_Calibration_Procedures.pdf\" target=\"_blank\"\u003ePDF Copy of Calibration Procedure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eCustomised models\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Special Builds\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/pages\/oztherm-phase-angle-controller-special-sp-builds\" target=\"_blank\"\u003eCustomised models list\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2b00ff;\"\u003e \u003ca style=\"color: #2b00ff;\" title=\"Contact Fastron\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/pages\/contact-us\" target=\"_blank\"\u003eContact Us for Possible Replacement\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e for customised features not listed\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Oztherm","offers":[{"title":"(FW) Four Wire \/ None \/ None","offer_id":18177428062323,"sku":"FE-F330-4-FW-N\/A","price":1417.0,"currency_code":"AUD","in_stock":true},{"title":"(FW) Four Wire \/ (PH) Phase Loss Alarm \/ None","offer_id":29555257016435,"sku":"FE-F330-4-FW-N\/A-PH","price":1768.0,"currency_code":"AUD","in_stock":true},{"title":"(FW) Four Wire \/ None \/ (C) Current Limt and Trip AC","offer_id":29555257049203,"sku":"FE-F330-4-FW-N\/A-C","price":2039.0,"currency_code":"AUD","in_stock":true},{"title":"(FW) Four Wire \/ (PH) Phase Loss Alarm \/ (C) Current Limt and Trip AC","offer_id":29555257081971,"sku":"FE-F330-4-FW-N\/A-C-PH","price":2087.0,"currency_code":"AUD","in_stock":true},{"title":"(FW) Four Wire \/ (PH) Phase Loss Alarm \/ (CC) Current Control","offer_id":29555257114739,"sku":"FE-F330-4-FW-N\/A-CC-PH","price":2087.0,"currency_code":"AUD","in_stock":true},{"title":"(FW) Four Wire \/ None \/ (C) Current Limt and Trip AC + (A) Voltage Regulation","offer_id":29555257147507,"sku":"FE-F330-4-FW-N\/A-A-C","price":2142.0,"currency_code":"AUD","in_stock":true},{"title":"(FW) Four Wire \/ (PH) Phase Loss Alarm \/ (C) Current Limt and Trip AC + (A) Voltage Regulation","offer_id":29555257180275,"sku":"FE-F330-4-FW-N\/A-A-C-PH","price":2190.0,"currency_code":"AUD","in_stock":true},{"title":"(FW) Four Wire \/ (PH) Phase Loss Alarm \/ (C) + (A) + (PW) Power Limit","offer_id":29555257213043,"sku":"FE-F330-4-FW-N\/A-A-C-PW-PH","price":2249.0,"currency_code":"AUD","in_stock":true},{"title":"3 Wire \/ None \/ None","offer_id":29555257245811,"sku":"FE-F330-4-N\/A","price":14170.0,"currency_code":"AUD","in_stock":true},{"title":"3 Wire \/ (PH) Phase Loss Alarm \/ None","offer_id":29555257278579,"sku":"FE-F330-4-N\/A-PH","price":1168.0,"currency_code":"AUD","in_stock":true},{"title":"3 Wire \/ None \/ (C) Current Limt and Trip AC","offer_id":29555257311347,"sku":"FE-F330-4-N\/A-C","price":2039.0,"currency_code":"AUD","in_stock":true},{"title":"3 Wire \/ (PH) Phase Loss Alarm \/ (C) Current Limt and Trip AC","offer_id":29555257344115,"sku":"FE-F330-4-N\/A-C-PH","price":2087.0,"currency_code":"AUD","in_stock":true},{"title":"3 Wire \/ (PH) Phase Loss Alarm \/ (CC) Current Control","offer_id":29555257376883,"sku":"FE-F330-4-N\/A-CC-PH","price":2087.0,"currency_code":"AUD","in_stock":true},{"title":"3 Wire \/ None \/ (C) Current Limt and Trip AC + (A) Voltage Regulation","offer_id":29555257409651,"sku":"FE-F330-4-N\/A-A-C","price":2142.0,"currency_code":"AUD","in_stock":true},{"title":"3 Wire \/ (PH) Phase Loss Alarm \/ (C) Current Limt and Trip AC + (A) Voltage Regulation","offer_id":29555257442419,"sku":"FE-F330-4-N\/A-A-C-PH","price":2190.0,"currency_code":"AUD","in_stock":true},{"title":"3 Wire \/ (PH) Phase Loss Alarm \/ (C) + (A) + (PW) Power Limit","offer_id":29555257475187,"sku":"FE-F330-4-N\/A-A-C-PW-PH","price":2249.0,"currency_code":"AUD","in_stock":true},{"title":"3 Wire \/ None \/ (CE) Current Limt and Trip DC","offer_id":39336252735622,"sku":"FE-F330-4-N\/A-CE","price":1654.0,"currency_code":"AUD","in_stock":true},{"title":"(FW) Four Wire \/ None \/ (CE) Current Limt and Trip DC","offer_id":39336252768390,"sku":"FE-F330-4-FW-N\/A-CE","price":1654.0,"currency_code":"AUD","in_stock":true},{"title":"3 Wire \/ (PH) Phase Loss Alarm \/ (CCE) Current Control DC","offer_id":39336252833926,"sku":"FE-F330-4-N\/A-CCE-PH","price":1702.0,"currency_code":"AUD","in_stock":true},{"title":"(FW) Four Wire \/ (PH) Phase Loss Alarm \/ (CCE) Current Control DC","offer_id":39336252866694,"sku":"FE-F330-4-FW-N\/A-CCE-PH","price":1702.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/oztherm-3-phase-scr-phase-angle-power-controller-cards-only-phase-angle-controller-f330-series-3-phase-cards-only-6324088275059.jpg?v=1610358241"},{"product_id":"f330-4-n-a-c-ph-option-card-only","title":"F330-4-N\/A-C-PH Option Card only","description":"\u003ch1\u003e\n\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eOztherm F330-4-N\/A-C-PH Series 3 Phase SCR Phase Angle Controller Spare Option Card\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003e, Can Replace Novatherm C3000A\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e100% Australian Made\u003c\/li\u003e\n\u003cli\u003e3 Phase, Phase Angle Controller or DC Soft Starter\u003c\/li\u003e\n\u003cli\u003e4-20mA, 0-5V, 0-10V or POT input Proportional Phase Control\u003c\/li\u003e\n\u003cli\u003ePhase angle switching\u003c\/li\u003e\n\u003cli\u003eOption Card Only\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter\u003c\/li\u003e\n\u003cli\u003eControlled Power Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003cli\u003eSheet Metal Welding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAvailable Options\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eVoltage Regulation AC (A)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Limit and Trip AC (C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Limit and Trip DC (CE)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Constant Current AC(CC)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Constant Current DC(CCE)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003ePower Limit (PW)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003ePhase Loss Alarm\/Dispable (PH)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoose Semiconductor Fuses (F)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eInternal Semiconductor\u003cspan\u003e \u003c\/span\u003eFuses (FI)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eThermal Overlad Protection (T)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSpecial Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003ew\/ +\/-15VDC Supply for Hall Sensor\u003c\/p\u003e\n\u003cp\u003e \u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/pages\/contact-us\" title=\"Contact Fastron\" target=\"_blank\"\u003e\u003cspan\u003eContact Us for Possible Replacement\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e for customised features\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 531px;\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 275.674px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eOztherm Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 252.326px;\"\u003eF330-4-N\/A-C-PH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 275.674px;\"\u003e\u003cstrong\u003eRated Operationg Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 252.326px;\"\u003e50\u003cspan\u003e°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 275.674px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 252.326px;\"\u003e3 Phase AC Swtich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 275.674px;\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 252.326px;\"\u003e4-20mA, 0-5V, 0-10V, 10K POT (4-20mA default calibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 275.674px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 252.326px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 275.674px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 252.326px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 275.674px;\"\u003e\u003cb\u003eSpecial Feature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 252.326px;\"\u003e\u003cstrong\u003e(Optional) Current Limit \u0026amp; Trip AC or DC, Current Control AC or DC, Voltage Regulation AC, Power Limit, Phase Loss Alarm, Thermal Overload Protection, Fuses \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 275.674px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 252.326px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 275.674px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 252.326px;\"\u003e380-440VAC +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 275.674px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 252.326px;\"\u003e1-20mS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 275.674px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 252.326px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 275.674px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 252.326px;\"\u003eup to 10kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 275.674px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 252.326px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eBrochure\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1539221128\/Fastron%20Stuff\/F-330_Brochure.pdf\" title=\"F330 Brochure\"\u003eF330 Brochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan color=\"#2b00ff\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581319211\/Fastron%20Stuff\/F330_Installation_Commissioning_Manual.pdf\" title=\"F330 User Manual\" target=\"_blank\"\u003eInstallation and Commissioning Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581302965\/Fastron%20Stuff\/F330_Thyristor_Wiring_DWG-1010-A2-ISS-01.pdf\" title=\"SCR Wiring 3 x AC switch\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyristor Wiring Diagram\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581302965\/Fastron%20Stuff\/F330_Control_Wiring_Complete_DWG-1084-A1..2-ISS-01.pdf\" title=\"Control Card Wiring Diagram\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eControl Card Wiring Diagram F311A1\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581302965\/Fastron%20Stuff\/F330_PCB1019-XX_Control_Wiring_Complete-DWG-1084A-A1..2-ISS-01.pdf\" title=\"New CCE Option Card wiring\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eNew CCE option PCB1019-XX Wiring Diagram\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581302965\/Fastron%20Stuff\/F330_Bridge_Thyritor_Wiring_DWG-1010-A1-ISS-01.pdf\" title=\"Bridge SCR Wiring 3 Phase\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBridge Output Thyristor Wiring Diagram\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581302965\/Fastron%20Stuff\/F330-Primary_Transformer_Wiring_DWG-1010-A4-ISS-01.pdf\" title=\"Tranformer Primary Wiring\" style=\"color: #2b00ff;\" target=\"_blank\"\u003ePrimary Transformer Wiring Diagram\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581302965\/Fastron%20Stuff\/SP100_Star_Delta_Dual_Bridge_Wiring_DWG-1010-A3-ISS-01.pdf\" title=\"Star Delta Wiring Diagram\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStart Delta Wiring Diagram\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/blogs\/power-controllers\/fastron-oztherm-power-controller-f330-series-calibration-procedure\" title=\"F330 Calibration Procedure\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eCalibration Procedure Blog\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1581321085\/Fastron%20Stuff\/F330_Calibration_Procedures.pdf\" title=\"F330 Calibration PDF Download\" style=\"color: #2b00ff;\" target=\"_blank\"\u003ePDF Copy of Calibration Procedure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eCustomised models\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/pages\/oztherm-phase-angle-controller-special-sp-builds\" title=\"Special Builds\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eCustomised models list\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/pages\/contact-us\" title=\"Contact Fastron\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eContact U\u003c\/span\u003es\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e for customised features not listed\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Oztherm","offers":[{"title":"Default Title","offer_id":29559755866227,"sku":"FE-F330-4-N\/A-C-PH Option Card only","price":871.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/ExistingF312A1_002.jpg?v=1626320902"},{"product_id":"tsg-v-ssr","title":"TSG-V, Intelligent voltage regulator for SSR or SCR Control (Choose one)","description":"\u003ch1\u003e\u003cspan style=\"color: #6ea4d7;\"\u003e\u003cstrong\u003eTSG-V (\u003c\/strong\u003e\u003cstrong\u003eZKG-2000)\u003cbr\u003eHigh quality and high accuracy voltage regulator \/\u003c\/strong\u003e\u003cstrong\u003eIntelligent voltage regulator for SCR or SSR Control (choose one model)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6ea4d7;\"\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eOutput impulse: Breadth value ≥ 3v, width ≥ 50us; S (when the load resistance is 20ohm)\u003c\/li\u003e\n\u003cli\u003eVoltage setting range: 0-200v(or the voltage range you want)\u003c\/li\u003e\n\u003cli\u003eWorking environment: Temperature 0-50 degrees celcius, relative humidity does not exceed 85%, non-corrosive environment.\u003c\/li\u003e\n\u003cli\u003ePower supply: AC 220v+\/-15%, 50Hz+\/-1Hz; About 3va\u003c\/li\u003e\n\u003cli\u003eSize: TSG-V 48x48x88mm TSA-V96*96*100mm TSD-V72*72*100mm\u003c\/li\u003e\n\u003cli\u003eTSG-2V 48*48*88(two voltage regulator in one unit)\u003c\/li\u003e\n\u003cli\u003eVoltage setting range: 0-200v(or the voltage range you want)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cp\u003e\u003cimg alt=\"Techncial Spec TSG-V Regulator\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/TSX-V_1024x1024.jpg?v=1579570951\"\u003e\u003c\/p\u003e\n\u003ch5\u003eWiring Diagram\u003c\/h5\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"Wiring Diagram for TSG-V\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/TSG-V_Wiring_600x600.png?v=1579570883\"\u003e\u003c\/p\u003e\n\u003ch5\u003eUser Manual\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"TSG-V User Manual\/Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1680575178\/Taisuo\/TS-V-INSTRUCTION_MANUAL.pdf\" target=\"_blank\"\u003eTSG-V Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003ch5\u003eRequired Accessories\u003c\/h5\u003e\n\u003cp\u003eSolid State relay and Heatsink is required sized large enough for the maximum continuous current of the load to be voltage regulated.\u003c\/p\u003e\n\u003cp\u003eSee \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Solid State Relay and Heatsink Combinations\" href=\"\/pages\/list-os-solid-state-relay-and-heatsink-assemblies\" target=\"_blank\"\u003ehere for complete list\u003c\/a\u003e\u003c\/span\u003e of possible combinations\u003c\/p\u003e","brand":"Taisuo","offers":[{"title":"SSR","offer_id":40141278281862,"sku":"FE-TSG-V-SSR","price":149.95,"currency_code":"AUD","in_stock":false},{"title":"SCR","offer_id":40141278347398,"sku":"FE-TSG-V-SCR","price":149.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/TSG-V.jpg?v=1624859599"},{"product_id":"fcog-6100-r","title":"FCOG-6100-R, 3 Phase Angle Control Cards 1200-480VAC, for Power Converters, AC or DC Drive Control","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eEnerpro FCOG-6100-R Series 3 Phase SCR Phase Angle Controller Card Set\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e100% USA Made\u003c\/li\u003e\n\u003cli\u003e3 Phase, Phase Angle Controller, AC or DC Soft Starter or Motor Controller\u003c\/li\u003e\n\u003cli\u003e4-20mA, 0-5V, 0-10V, 1-2V, or Custom input Proportional Phase Control\u003c\/li\u003e\n\u003cli\u003ePhase Angle SCR Switching\u003c\/li\u003e\n\u003cli\u003eCard Only\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDrives, Synchronous and Asynchronous\u003c\/li\u003e\n\u003cli\u003eReversing Rectifiers (Special Option)\u003c\/li\u003e\n\u003cli\u003eExciters\u003c\/li\u003e\n\u003cli\u003eSiemens Simovert Replacement Cards\u003c\/li\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter\u003c\/li\u003e\n\u003cli\u003eControlled Power Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003cli\u003eSheet Metal Welding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAvailable Configurations\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAC Converter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e6 SCR\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eParallel SCR\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6ea7dc;\"\u003e\u003cstrong\u003eDC Converters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eTwo Quadrant, Parallel SCR\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eTwo Quadrant, 6 SCR\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSpecial Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/pages\/contact-us\" target=\"_blank\" title=\"Contact Fastron\" rel=\"noopener noreferrer\"\u003e\u003cspan\u003eContact Us for Possible Replacement\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e for customised features\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSee below for Optional card sets\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\" style=\"width: 531px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 228.729px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eEnerpro Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 299.271px;\"\u003eFCOG-6100-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 228.729px;\"\u003e\u003cstrong\u003eRated Operationg Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 299.271px;\"\u003e50\u003cspan\u003e°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 228.729px;\"\u003e\u003cstrong\u003eResponse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 299.271px;\"\u003e\u0026lt; 20mS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 228.729px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 299.271px;\"\u003e3 Phase AC Swtich\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 228.729px;\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 299.271px;\"\u003e4-20mA, 0-5V, 0-10V, 10K POT (4-20mA default calibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 228.729px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 299.271px;\"\u003eDepends on SCR stack\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 228.729px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 299.271px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 228.729px;\"\u003e\u003cb\u003eSpecial Feature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 299.271px;\"\u003e\u003cstrong\u003eSee Optional Card Sets below\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 228.729px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 299.271px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 228.729px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 299.271px;\"\u003e380-440VAC +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 228.729px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 299.271px;\"\u003eCustomisable\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 228.729px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 299.271px;\"\u003eConnector\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 228.729px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 299.271px;\"\u003e2-3kg\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 228.729px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 299.271px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1582165000\/Enerpro\/Brochures\/PD720_FCOG6100_Product_Guide_07-2017.pdf\" target=\"_blank\" title=\"FCOG6100 Product Guide\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003eFCOG-6100-R Product Guide\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1582164930\/Enerpro\/Manuals\/R380_FCOG6100_Rev_R_Operating_Manual_Rev_C_Apr_2011.pdf\" target=\"_blank\" title=\"FCOG6100 Manual\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003eFCOG-6100-R Product Guide\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1582165207\/Enerpro\/Manuals\/CTRCT-1_OPS_MAN.pdf\" target=\"_blank\" title=\"CTRCT-1 Manual\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003eCTRCT-1 Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1582165238\/Enerpro\/Manuals\/CTRCT-2_OPS_MAN.pdf\" target=\"_blank\" title=\"CTSCT-2 Manual\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003eCTRCT-2 Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1582165200\/Enerpro\/Manuals\/R188_FCRO2100_Rev_H_Operating_Manual_Rev_C_Jun_2011.pdf\" target=\"_blank\" title=\"FC0R2100 manual\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003eSFCO2100-H Single Phase Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eOptional Cards\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1582165014\/Enerpro\/Brochures\/PD776_CTRCT1_2_Prod_Gd_07-2017.pdf\" target=\"_blank\" title=\"CTRCT1 Regulator Board\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003e CTRCT1 Current or Voltage Regulator Board\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1582165014\/Enerpro\/Brochures\/PD779_ISOVLCL2_ProdGd_06-2015.pdf\" target=\"_blank\" title=\"Firing Regulator Board\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003eISOVLCL2 Firing Card will Regulation\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1582165014\/Enerpro\/Brochures\/PD775_ISOVLCL3_ProdGd_06-2015.pdf\" target=\"_blank\" title=\"ISOVLC3 Current Regulator Board\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003eISOVLCL3 Current Regulator Board\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1582165000\/Enerpro\/Brochures\/PD740_FRS300_ProdGd_06-2015.pdf\" target=\"_blank\" title=\"FRS300 Product Guide\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003eFRS300 3 Phase Half Contolled with Snubber\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1582165000\/Enerpro\/Brochures\/PD741_FCOG61HV_ProdGd_06-2015.pdf\" target=\"_blank\" title=\"High Voltaeg SCR Firing Card\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003eHigh Voltage Firing Card\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1582165007\/Enerpro\/Brochures\/PD719_FCRO2100_ProdGd_06-2015.pdf\" target=\"_blank\" title=\"FCRO2100\" style=\"color: #2b00ff;\" rel=\"noopener noreferrer\"\u003eFCO2100-H Single Phase, Phase Control Card\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2b00ff;\"\u003e \u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/pages\/contact-us\" target=\"_blank\" title=\"Contact Fastron\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003eContact Us for Possible Replacement\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e for customised features not listed\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Enerpro","offers":[{"title":"Default Title","offer_id":31422839259270,"sku":"FE-FCOG-6100-R","price":2190.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FCOG6100-R.jpg?v=1650942625"},{"product_id":"thyro-bus-module","title":"Thyro Bus Module, 4 Channel programing interface for Thyro Series SCR Controllers \u0026 Solid State Contactors","description":"\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy Thyro Series Communication Bus Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Connection for up to 8 Power Controllers\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOne Address per Module\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAccess to controller setpoints, actual points, and parameters\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTransfer of setpoints as float number in physical units\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eControl Function of LED's\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e24VDC 150mA Supply\u003c\/li\u003e\n\u003cli\u003eUL and CE Approved\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eThyro S, Thyro A, Thyro AX\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #86b0d4;\"\u003e\u003cstrong\u003eCommunication Options :\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet (Inc Ethern\/IP\/Profinet\/Modbus TCP\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfibus DPV1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModbus RTU\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cbr\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 530px;\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Numbers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eEthernet(2.000.000.846), ProfibusDPV1(2.000.000.841) ModbusRTU(2.000.000.842) DeviceNet(2.000.000.844)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eAccess to controller setpoints, actual points, and parameters\u003cbr\u003eTransfer of setpoints as float number in physical units\u003cbr\u003eControl Function of LED's\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\u003cspan\u003e24VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan\u003eEthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eNo. of Communicaton Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eUp to 8\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e750g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cb\u003eApprovals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eCE, UL\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e-20 →+70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" title=\"Com Bus Module Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Ethernet \/ 4 Channel","offer_id":31557820448902,"sku":"FE-Thyro Bus Module-1","price":1171.5,"currency_code":"AUD","in_stock":false},{"title":"Profibus DPV1 \/ 4 Channel","offer_id":31557820481670,"sku":"FE-Thyro Bus Module-2","price":1171.5,"currency_code":"AUD","in_stock":true},{"title":"Modbus RTU \/ 4 Channel","offer_id":31557820514438,"sku":"FE-Thyro Bus Module-3","price":1171.5,"currency_code":"AUD","in_stock":true},{"title":"DeviceNet \/ 4 Channel","offer_id":31557820547206,"sku":"FE-Thyro Bus Module-4","price":1171.5,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/ThyroSeriesBusModule.jpg?v=1624861471"},{"product_id":"basic-bus-module","title":"Basic Bus \u0026 dASM Modules, 8 Channel Communication Interface for Thyro Series SCR Controllers","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy Basic Bus \u0026amp; dASM Modules, 8 Channel Communication Interface for Thyro Series SCR Controllers\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eNote: Basicbus not required For Thyro PX Controllers, only requires Anybus and dASM (for Dynamic Mains load optimised Burst Fire Modes)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e​\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Connection for up to 8 Power Controllers (32 Optional)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOne Address per Module\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAccess to controller setpoints, actual points, and parameters\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTransfer of setpoints as float number in physical units\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eControl Function of LED's\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e24VDC 200mA Supply\u003c\/li\u003e\n\u003cli\u003eUL and CE Approved\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eThyro S, Thyro A, Thyro AX\u003c\/li\u003e\n\u003cli\u003eNote Requires \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Anybus Module Page\" href=\"dasm-module\"\u003eAnybus\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e Module\u003c\/span\u003e\u003c\/a\u003e \u003cspan style=\"color: #000000;\"\u003efor dASM Mode(TAKT Control Only)\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #86b0d4;\"\u003e\u003cstrong\u003eCommunication Options :\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet (Inc Ethern\/IP\/Profinet\/Modbus TCP\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfibus DPV1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModbus RTU\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 530px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Numbers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e2.000.190.002,\u003cspan\u003e2.000.190.003\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eAccess to controller setpoints, actual points, and parameters\u003cbr\u003eTransfer of setpoints as float number in physical units\u003cbr\u003eControl Function of LED's\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\u003cspan\u003e24VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan\u003eEthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet (with Suitable Anybus Module)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eNo. of Communication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eUp to 8\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e750g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cb\u003eApprovals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eCE, UL\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e-20 →+70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Com Bus Module Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eUser Manual\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Advance Energy BasicBus model user guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1623397864\/Advanced%20Energy\/User%20Manuals\/en-scr-thyro-basic-busmodule-operating-manual.pdf\" target=\"_blank\"\u003eUser Guide\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/power-controllers\/setting-up-the-advanced-energy-basicbus-module-for-string-communications-of-thyro-pcm-scr-controllers\" title=\"Blog\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eBlog for initial communication setup issue\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Basicbus With dASM","offer_id":31557890572422,"sku":"FE-2.000.190.003","price":1252.9,"currency_code":"AUD","in_stock":true},{"title":"Basicbus With dASM and 2.5M Cables","offer_id":31557890605190,"sku":"FE-BasicBus Module with dASM \u0026 4 x 2.5M Cables\/Plug","price":1384.9,"currency_code":"AUD","in_stock":false},{"title":"Basicbus With dASM and 1.5M Cables","offer_id":31557890637958,"sku":"FE-BasicBus Module with dASM \u0026 4 x 1.5M Cable\/Plug","price":1379.4,"currency_code":"AUD","in_stock":false},{"title":"Basicbus Without dASM (VAR Mode)","offer_id":31557898371206,"sku":"FE-2.000.190.002","price":731.5,"currency_code":"AUD","in_stock":true},{"title":"Basicbus Without dASM and 2.5M Cables","offer_id":39401183871110,"sku":"FE-BasicBus Module w\/o dASM \u0026 4 x 2.5M Cables\/Plug","price":958.1,"currency_code":"AUD","in_stock":false},{"title":"Basicbus Without dASM and 1.5M Cables","offer_id":39401183903878,"sku":"FE-BasicBus Module w\/o dASM \u0026 4 x 1.5M Cables\/Plug","price":952.6,"currency_code":"AUD","in_stock":false},{"title":"dASM Card for Thyro PX ONLY","offer_id":41554226380934,"sku":"FE-2.000.590.003","price":325.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/BasicBusModule_053dd141-3e15-40df-9719-19d7bccbbbde.png?v=1661733032"},{"product_id":"4-basicbus-cables-comic-plug","title":"Cables and\/or COMBIC for Thyro Series Comunication Interface","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy 4 BasicBus Cables + COMIC Plug, cables for programming interface for Thyro Series SCR Controllers\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Connection for up to 8 Power Controllers (32 Optional)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOne Address per Module\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAccess to controller setpoints, actual points, and parameters\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTransfer of setpoints as float number in physical units\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eControl Function of LED's\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e24VDC 200mA Supply\u003c\/li\u003e\n\u003cli\u003eUL and CE Approved\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eThyro S, Thyro A, Thyro AX\u003c\/li\u003e\n\u003cli\u003eNote Requires \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"dASm Module Page\" href=\"dasm-module\" target=\"_blank\"\u003edASM Module\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #86b0d4;\"\u003e\u003cstrong\u003eCommunication Options :\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet (Inc Ethern\/IP\/Profinet\/Modbus TCP\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfibus DPV1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModbus RTU\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 530px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Numbers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e2000004015\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eAccess to controller setpoints, actual points, and parameters\u003cbr\u003eTransfer of setpoints as float number in physical units\u003cbr\u003eControl Function of LED's\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\u003cspan\u003e24VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan\u003eEthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eNo. of Communication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eUp to 8\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e800g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cb\u003eApprovals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eCE, UL\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e-20 →+70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Com Bus Module Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eUser Manual\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1623397864\/Advanced%20Energy\/User%20Manuals\/en-scr-thyro-basic-busmodule-operating-manual.pdf\" title=\"Advance Energy BasicBus model user guide\" target=\"_blank\"\u003eUser Guide\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Busmodule \/ 1.5M","offer_id":34863497150598,"sku":"FE-4 Busmodule Cables + Shield 1.5M","price":196.9,"currency_code":"AUD","in_stock":false},{"title":"Busmodule \/ 2.5M","offer_id":34863497183366,"sku":"FE-4 BasicBus Cables + Shield 2.5M","price":212.3,"currency_code":"AUD","in_stock":true},{"title":"Busmodule \/ 4M","offer_id":34863497216134,"sku":"FE-4 BasicBus Cables + Shield 4M","price":229.9,"currency_code":"AUD","in_stock":false},{"title":"4 x Basicbus Module \u0026 Combic Plug \/ 1.5M","offer_id":34863497248902,"sku":"FE-4 BasicBus Cables 1.5M + COMIC Plug","price":218.9,"currency_code":"AUD","in_stock":false},{"title":"4 x Basicbus Module \u0026 Combic Plug \/ 2.5M","offer_id":34863497281670,"sku":"FE-4 BasicBus Cables 2.5M + COMIC Plug","price":224.4,"currency_code":"AUD","in_stock":false},{"title":"4 x Basicbus Module \u0026 Combic Plug \/ 4M","offer_id":34863497314438,"sku":"FE-4 BasicBus Cables 4M + COMIC Plug","price":229.9,"currency_code":"AUD","in_stock":false},{"title":"Combic Plug Only \/ N\/A","offer_id":39375727100038,"sku":"FE-8.000.056.632","price":9.9,"currency_code":"AUD","in_stock":true},{"title":"1 x Basicbus Module \u0026 Combic Plug \/ 1.5M","offer_id":39466480992390,"sku":"FE-1 BasicBus Cables 1.5M + COMIC Plug","price":64.9,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/BasicBusModule_089ae946-96e2-4e5e-8395-710a20246d9e.png?v=1661733117"},{"product_id":"fycf-1","title":"FYCF-1, Single Phase Voltage Control SCR Trigger Module, 4-20mA,2-10V,1-5V,5K POT Input, 200-450VAC, 12VDC Aux Supply","description":"\u003cp\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFastron FYCF-1, Single Phase Voltage Control SCR Trigger Module, 4-20mA,2-10V,1-5V,5K POT Input, 200-450VAC, 12VDC Aux Supply. Can Replace Semikron Semi-PCM 2 SKPC200\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4-20mA,2-10V, 1-5V or 10K POT Proportional Phase Control Input\u003c\/li\u003e\n\u003cli\u003eSuitable for SCR Blocks up to 3000 Amp\u003c\/li\u003e\n\u003cli\u003eInstantaneous turn-on output\u003c\/li\u003e\n\u003cli\u003eCE Approval (Pending)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan Replace Semikron Semi-PCM 2 SKPC200 for most applications\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFastron part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eFYCF-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSwitching Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Angle (Random Crossing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e4-20mA,\u003c\/span\u003e\u003cspan\u003e2\u003c\/span\u003e\u003cspan\u003e-10V,1-5V,10K POT Proportional Input\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBased on SCR Stack\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eSpecial Feature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Phase Proportional Controller\/Trigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-450VAC +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBarrier Strip Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 x 90 x 40mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet and User Manual\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1603864390\/Fastron%20Stuff\/FYFC-1_Single_Phase_SCR_Gate_Trigger_Module_merged.pdf\" title=\"FYFC-1 Voltage Regulator SCR Trigger Module Datasheet\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eFYCF-1\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fastron Electronics","offers":[{"title":"Default Title","offer_id":34859416420486,"sku":"FE-FYCF-1","price":195.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FYCF-1WiringPicture_7219b7a3-3595-4a13-ad64-bc6af993e046.jpg?v=1650946246"},{"product_id":"thyro-tool-pro-software-software-for-advanced-energy-scr-controller","title":"Thyro Tool Pro Software CDROM - Software for Advanced Energy SCR Controller","description":"\u003cp\u003e\u003cspan style=\"color: #6ea4d7;\"\u003e\u003cstrong\u003eSoftware for Advanced Energy SCR Controller\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor setting up Communication addresses via USB and configuring SCR Controllers Locally or remotely. Highly valueable for controller diagnostics, fault finding and communication validation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1623397864\/Advanced%20Energy\/User%20Manuals\/en-scr-thyro-basic-busmodule-operating-manual.pdf\" title=\"Thyro Tool Pro User Manual\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eBasic Bus User Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installtion Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installtion Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":39386543292550,"sku":"FE-Thyro Tool Pro Software","price":899.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/ThyroToolPro.jpg?v=1624859006"},{"product_id":"fycf-3","title":"FYCF-3, Three Phase Voltage Control SCR Trigger Module, 4-20mA,2-10V,1-5V,5K POT Input, 200-450VAC, 12VDC Aux Supply","description":"\u003cp\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFastron FYCF-3, Three Phase Voltage Control SCR Trigger Module, 4-20mA,2-10V,1-5V,5K POT Input, 200-450VAC, 12VDC Aux Supply. Can Replace Semikron Semi-PCM 2 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4-20mA,2-10V, 1-5V or 10K POT Proportional Phase Control Input\u003c\/li\u003e\n\u003cli\u003eSuitable for SCR Blocks up to 3000 Amp\u003c\/li\u003e\n\u003cli\u003eInstantaneous turn-on output\u003c\/li\u003e\n\u003cli\u003eCE Approval (Pending)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan Replace Semikron Semi-PCM 2 SKPC200 for most applications\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFastron part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eFYCF-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSwitching Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Angle (Random Crossing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e4-20mA,\u003c\/span\u003e\u003cspan\u003e2\u003c\/span\u003e\u003cspan\u003e-10V,1-5V,10K POT Proportional Input\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBased on SCR Stack\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eSpecial Feature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Phase Proportional Controller + SSR\/3 Phase Voltage Regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-450VAC +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBarrier Strip Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 x 90 x 40mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet and User Manual\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1628480561\/Fastron%20Stuff\/FYFC-3_Three_phase_trigger_user_manual.pdf\" title=\"FYFC-3 Voltage Regulator SCR Trigger Module Datasheet\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eFYCF-3\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fastron Electronics","offers":[{"title":"Default Title","offer_id":39451379957894,"sku":"FE-FYCF-3","price":295.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FYCF-3front_c50884df-200c-462c-a0ab-111776912466.jpg?v=1650950299"},{"product_id":"fycf-3r","title":"FYCF-3R, Three Phase Voltage Control SCR Trigger Module with Soft Start Function, 4-20mA,2-10V,1-5V,5K POT Input, 200-450VAC, 12VDC Aux Supply","description":"\u003cp\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFastron FYCF-3R, Three Phase Voltage Control SCR Trigger Module with Soft Start Function, 4-20mA,2-10V,1-5V,5K POT Input, 200-450VAC, 12VDC Aux Supply. Can Replace Semikron Semi-PCM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4-20mA,2-10V, 1-5V or 10K POT Proportional Phase Control Input\u003c\/li\u003e\n\u003cli\u003eSuitable for SCR Blocks up to 3000 Amp\u003c\/li\u003e\n\u003cli\u003eInstantaneous turn-on output\u003c\/li\u003e\n\u003cli\u003eCE Approval (Pending)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan Replace Semikron Semi-PCM 2 SKPC200 for most applications\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFastron part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eFYCF-3R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSwitching Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Angle (Random Crossing) with Soft Start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e4-20mA,\u003c\/span\u003e\u003cspan\u003e2\u003c\/span\u003e\u003cspan\u003e-10V,1-5V,10K POT Proportional Input\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBased on SCR Stack\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eSpecial Feature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Phase Proportional Controller + SSR\/3 Phase Voltage Regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-450VAC +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBarrier Strip Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 x 90 x 40mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet and User Manual\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1628480561\/Fastron%20Stuff\/FYFC-3_Three_phase_trigger_user_manual.pdf\" title=\"FYFC-3 Voltage Regulator SCR Trigger Module Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eFYCF-3\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fastron Electronics","offers":[{"title":"Default Title","offer_id":39452979167366,"sku":"FE-FYCF-3R","price":329.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FYCF-3front.jpg?v=1650950312"},{"product_id":"8-000-006-763","title":"8000006763, Din Rail Mount Adaptor for Thyro A1A, Thyro S1S, 16 Amp and 30 Amp models only","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy 8.000.006.763, Din Rail Mount Adaptor for Thyro A1A, Thyro S1S, 16 Amp and 30 Amp models only\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Din Rail Adaptor for Din Rail Mounting of 16 A,mp and 30 Amp THyro A1A and Thyro S1S Models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #86b0d4;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" title=\"Com Bus Module Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":39617519648902,"sku":"FE-8.000.006.763","price":34.65,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/DinRailAdaptor.png?v=1638226918"},{"product_id":"fkpc-240-ce","title":"FKPC200-400 (FKPC-240-CE), Single Phase Voltage Control SCR Trigger Module, 4-20mA,2-10V,1-5V,5K POT Input, 200-450VAC, 240VAC Aux Supply, CE Approved, See FKPC-200-400 REV 2 FOR UPDATED DESIGN","description":"\u003cp\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFastron FKPC200-400 (FKPC-240-CE), Single Phase Voltage Control SCR Trigger Module, 4-20mA,2-10V,1-5V,5K POT Input, 200-450VAC, 240VAC Aux Supply, CE Approved, See FKPC-200-400 REV 2 FOR UPDATED DESIGN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRev 1 Supports Input:4-20mA,2-10V, 1-5V or 10K POT\u003c\/strong\u003e Proportional Phase Control Input\u003c\/li\u003e\n\u003cli\u003eSuitable for SCR Blocks up to 3000 Amp\u003c\/li\u003e\n\u003cli\u003eInstantaneous turn-on output\u003c\/li\u003e\n\u003cli\u003eCE Approval (Pending)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan Replace Semikron Semi-PCM 2 SKPC200 for most applications. Please take care to connect 240VAC Aux Supply Seperately and connect the gate leads to cathode rather than anode \u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFastron part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eFKPC200-400 (Previously FKPC-240-CE) (Possible Replacement to SKPC200-240)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSwitching Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Angle (Random Crossing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20mA,2-10V,1-5V,10K POT Proportional Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBased on SCR Stack\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eSpecial Feature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Phase Proportional Controller\/Trigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-450VAC +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBarrier Strip Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 x 90 x 40mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertifications EMC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-3:2007+A1:2011, \u003cspan data-mce-fragment=\"1\"\u003eEN IEC 61000-3-2:2019+A1:2021, EN 61000-3-3:2013+A1:2019, EN IEC 61000-6-1:2019\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertifications LVD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eLow Voltage Directive 2014\/35\/EU, EN IEC 60947-\u003c\/span\u003e\u003cspan\u003e1\u003c\/span\u003e\u003cspan\u003e:2021\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet and User Manual\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1681869917\/Fastron%20Stuff\/FKPC_trigger_module_datasheet.pdf\" target=\"_blank\" title=\"FKPC240-400 Voltage Regulator SCR Trigger Module Datasheet\" rel=\"noopener\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"FKPC240-400 Voltage Regulator SCR Trigger Module Wiring for 400VAC\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1713237471\/Fastron%20Stuff\/FKPC200-400_Half_Controller_Bridge_Wiring_Crydom_M505012F_or_M5010012F.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eFKPC wiring Half Controlled M505012F Crydom Bridge for up to 240VAC - 400VAC Load\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"FKPC240-400 Voltage Regulator SCR Trigger Module Wiring for 400VAC\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1713237463\/Fastron%20Stuff\/SKCH_Half_Controlled_Bridge_Wiring.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eFKPC wiring Half Controlled SKCH28\/16 Bridge for up to 240VAC - 400VAC Load\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1682328169\/Fastron%20Stuff\/FKPC200-400_AC_Switch_Wiring.pdf\" title=\"FKCP AC Switch Wiring\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eFKPC AC Switch Wiring\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fastron Electronics","offers":[{"title":"Default Title","offer_id":39691070832774,"sku":"FE-FKPC-240-CE","price":295.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FKPCAngle.png?v=1655257840"},{"product_id":"fkpc-240-ce-rev-2","title":"FKPC-200-400 Rev 2 (FKPC-240-CE Rev 2), Single Phase Voltage Control SCR Trigger Module, 4-20mA,0-10V,0-5V,5K POT Input, 200-450VAC, 240VAC Aux Supply, Can Replace Semikron Semi-PCM 2 SKPC200-240","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFastronFKPC-200-400 Rev 2, Single Phase Voltage Control SCR Trigger Module, 4-20mA,0-10V,0-5V,5K POT Input, 200-450VAC, 240VAC Aux Supply, Can Replace Semikron Semi-PCM 2 SKPC200-240, CE Approved, Previously FKPC-240-CE Rev 2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRev 2: Supports Inputs: 4-20mA,0-10V, 0-5V or 10K POT\u003c\/strong\u003e Proportional Phase Control Input\u003c\/li\u003e\n\u003cli\u003eSuitable for SCR Blocks up to 3000 Amp\u003c\/li\u003e\n\u003cli\u003eInstantaneous turn-on output\u003c\/li\u003e\n\u003cli\u003eCE Approval (Pending)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan Replace Semikron Semi-PCM 2 SKPC200 for most applications. Please take care to connect 240VAC Aux Supply Seperately and connect the gate leads to cathode rather than anode \u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFastron part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eFKPC200-400 Rev 2 (Previously FKPC-240-CE Rev 2) (Possible Replacement to SKPC200-240)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSwitching Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Angle (Random Crossing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20mA,0-10V,0-5V,10K POT Proportional Input (Note the zero value is 0.20.3V to avoid noise to cause gate firing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBased on SCR Stack\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eSpecial Feature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Phase Proportional Controller\/Trigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-450VAC +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAuxiliary Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200-450VAC +10%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBarrier Strip Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 x 90 x 40mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertifications EMC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-3:2007+A1:2011, \u003cspan data-mce-fragment=\"1\"\u003eEN IEC 61000-3-2:2019+A1:2021, EN 61000-3-3:2013+A1:2019, EN IEC 61000-6-1:2019\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eCertifications LVD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eLow Voltage Directive 2014\/35\/EU, EN IEC 60947-\u003c\/span\u003e\u003cspan\u003e1\u003c\/span\u003e\u003cspan\u003e:2021\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet and User Manual\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1731999096\/Fastron%20Stuff\/FKPC_trigger_module_datasheet_New_Rev_2.pdf\" title=\"FKPC240-400 Rev 2 Voltage Regulator SCR Trigger Module Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1713237471\/Fastron%20Stuff\/FKPC200-400_Half_Controller_Bridge_Wiring_Crydom_M505012F_or_M5010012F.pdf\" title=\"FKPC240-400 Voltage Regulator SCR Trigger Module Wiring for 400VAC\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eFKPC wiring Half Controlled M505012F Crydom Bridge for up to 240VAC - 400VAC Load\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1713237463\/Fastron%20Stuff\/SKCH_Half_Controlled_Bridge_Wiring.pdf\" title=\"FKPC240-400 Voltage Regulator SCR Trigger Module Wiring for 400VAC\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eFKPC wiring Half Controlled SKCH28\/16 Bridge for up to 240VAC - 400VAC Load\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1682328169\/Fastron%20Stuff\/FKPC200-400_AC_Switch_Wiring.pdf\" title=\"FKCP AC Switch Wiring\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eFKPC AC Switch Wiring\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fastron Electronics","offers":[{"title":"Default Title","offer_id":40275570688134,"sku":"FE-FKPC-240-CE Rev 2","price":325.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FKPCAngle_e369b367-aace-4233-9c14-980a867ca514.png?v=1737679305"},{"product_id":"thyro-s2s-series","title":"Thyro S 2S Series 2 Leg 3 Phase Solid State Contactor 16 - 1500Amp 400VAC +10\/-15% Burst(TAKT) Fire Mode, Economical Firing Mode","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro S 2S Series 2 Leg 3 Phase Solid State Contactor, Burst(TAKT)Firing Mode Only. Compatible Replacement for Eurotherm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, 2 Leg Economical Burst Controller Firing Mode\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #90b7dc;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #82aad4;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8cb3dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #75a6da;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro S 2S 400VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2 Leg Burst(TAKT) for low dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354020\/Advanced%20Energy\/User%20Manuals\/thyro-a-om-en.pdf\" title=\"Thyro A User Manual\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\"\u003e2 Leg Control Application Blog\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installtion Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" title=\"Ethernet IP Setup Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan color=\"#2b00ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"16 Amp \/ H3 - U,U² \/ No","offer_id":40945123065990,"sku":"FE-Thyro S 2S 400-16 H3","price":1266.46,"currency_code":"AUD","in_stock":false},{"title":"30 Amp \/ H3 - U,U² \/ No","offer_id":40945123098758,"sku":"FE-Thyro S 2S 400-30 H3","price":1657.58,"currency_code":"AUD","in_stock":false},{"title":"45 Amp \/ H3 - U,U² \/ No","offer_id":40945123131526,"sku":"FE-Thyro S 2S 400-45 H3","price":1799.27,"currency_code":"AUD","in_stock":false},{"title":"60 Amp \/ H3 - U,U² \/ No","offer_id":40945123164294,"sku":"FE-Thyro S 2S 400-60 H3","price":2048.32,"currency_code":"AUD","in_stock":false},{"title":"100 Amp \/ H3 - U,U² \/ No","offer_id":40945123197062,"sku":"FE-Thyro S 2S 400-100 H3","price":2428.4,"currency_code":"AUD","in_stock":false},{"title":"130 Amp \/ H3 - U,U² \/ No","offer_id":40945123229830,"sku":"FE-Thyro S 2S 400-130 H3","price":2542.91,"currency_code":"AUD","in_stock":false},{"title":"170 Amp \/ H3 - U,U² \/ No","offer_id":40945123262598,"sku":"FE-Thyro S 2S 400-170 H3","price":3003.0,"currency_code":"AUD","in_stock":false},{"title":"280 Amp \/ H3 - U,U² \/ No","offer_id":40945123295366,"sku":"FE-Thyro S 2S 400-280 H3","price":4156.9,"currency_code":"AUD","in_stock":false},{"title":"350 Amp \/ H3 - U,U² \/ No","offer_id":40945123328134,"sku":"FE-Thyro S 2S 400-350 H3","price":5045.7,"currency_code":"AUD","in_stock":false},{"title":"16 Amp \/ HRL3 - U,U²,I,I² \/ No","offer_id":40945123360902,"sku":"FE-Thyro S 2S 400-16 HRL3","price":1765.93,"currency_code":"AUD","in_stock":false},{"title":"30 Amp \/ HRL3 - U,U²,I,I² \/ No","offer_id":40945123393670,"sku":"FE-Thyro S 2S 400-30 HRL3","price":1845.61,"currency_code":"AUD","in_stock":false},{"title":"45 Amp \/ HRL3 - U,U²,I,I² \/ No","offer_id":40945123426438,"sku":"FE-Thyro S 2S 400-45 HRL3","price":2272.22,"currency_code":"AUD","in_stock":false},{"title":"60 Amp \/ HRL3 - U,U²,I,I² \/ No","offer_id":40945123459206,"sku":"FE-Thyro S 2S 400-60 HRL3","price":2435.76,"currency_code":"AUD","in_stock":false},{"title":"100 Amp \/ HRL3 - U,U²,I,I² \/ No","offer_id":40945123491974,"sku":"FE-Thyro S 2S 400-100 HRL3","price":3023.37,"currency_code":"AUD","in_stock":false},{"title":"130 Amp \/ HRL3 - U,U²,I,I² \/ No","offer_id":40945123524742,"sku":"FE-Thyro S 2S 400-130 HRL3","price":3499.13,"currency_code":"AUD","in_stock":false},{"title":"170 Amp \/ HRL3 - U,U²,I,I² \/ No","offer_id":40945123557510,"sku":"FE-Thyro S 2S 400-170 HRL3","price":3661.9,"currency_code":"AUD","in_stock":false},{"title":"280 Amp \/ HRL3 - U,U²,I,I² \/ No","offer_id":40945123590278,"sku":"FE-Thyro S 2S 400-280 HRL3","price":5242.6,"currency_code":"AUD","in_stock":false},{"title":"350 Amp \/ HRL3 - U,U²,I,I² \/ No","offer_id":40945123623046,"sku":"FE-Thyro S 2S 400-350 HRL3","price":6220.5,"currency_code":"AUD","in_stock":false},{"title":"16 Amp \/ HRLP3 - U,U²,I,I²,P \/ No","offer_id":40945123655814,"sku":"FE-Thyro S 2S 400-16 HRLP3","price":2135.1,"currency_code":"AUD","in_stock":false},{"title":"30 Amp \/ HRLP3 - U,U²,I,I²,P \/ No","offer_id":40945123688582,"sku":"FE-Thyro S 2S 400-30 HRLP3","price":2680.7,"currency_code":"AUD","in_stock":false},{"title":"45 Amp \/ HRLP3 - U,U²,I,I²,P \/ No","offer_id":40945123721350,"sku":"FE-Thyro S 2S 400-45 HRLP3","price":2981.0,"currency_code":"AUD","in_stock":false},{"title":"60 Amp \/ HRLP3 - U,U²,I,I²,P \/ No","offer_id":40945123754118,"sku":"FE-Thyro S 2S 400-60 HRLP3","price":3298.54,"currency_code":"AUD","in_stock":false},{"title":"100 Amp \/ HRLP3 - U,U²,I,I²,P \/ No","offer_id":40945123786886,"sku":"FE-Thyro S 2S 400-100 HRLP3","price":3682.8,"currency_code":"AUD","in_stock":false},{"title":"130 Amp \/ HRLP3 - U,U²,I,I²,P \/ No","offer_id":40945123819654,"sku":"FE-Thyro S 2S 400-130 HRLP3","price":4107.4,"currency_code":"AUD","in_stock":false},{"title":"170 Amp \/ HRLP3 - U,U²,I,I²,P \/ No","offer_id":40945123852422,"sku":"FE-Thyro S 2S 400-170 HRLP3","price":4519.9,"currency_code":"AUD","in_stock":false},{"title":"280 Amp \/ HRLP3 - U,U²,I,I²,P \/ No","offer_id":40945123885190,"sku":"FE-Thyro S 2S 400-280 HRLP3","price":6155.6,"currency_code":"AUD","in_stock":false},{"title":"350 Amp \/ HRLP3 - U,U²,I,I²,P \/ No","offer_id":40945123917958,"sku":"FE-Thyro S 2S 400-350 HRLP3","price":7229.2,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyro-a-500x500_56792cb0-342d-4a57-8bcb-23cc67a7edd9.jpg?v=1714705694"},{"product_id":"thyro-s3s-series","title":"Thyro S 3S Series Three Phase SCR Controller 16 - 1500Amp 400VAC +10\/-15%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro S 3S Series Three Phase SCR Power Controller, 16-1500Amp, 400VAC, Phase(VAR), Burst(TAKT), SWITCH Operating Modes. Compatible Replacement for Eurotherm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e400VAC +10\/-57% \u003cspan\u003eLine to Line Voltage, Current or Power Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustments\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function for Multiple TAKT Sync\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eResistive Loads up to 6:1 Hot\/Cold Ratio\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (VAR Mode Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #77a6d9;\"\u003e\u003cstrong\u003eSeries Optional Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #75a2d1;\"\u003eFor HRL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #78a3d1;\"\u003e\u003cstrong\u003eFor HRLP\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #7da6d2;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro S 3S 400VAC or \u003cspan data-mce-fragment=\"1\"\u003eThyro S 3S \u003c\/span\u003e500VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e400VAC +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 74kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eBrochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro A User Manual\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354020\/Advanced%20Energy\/User%20Manuals\/thyro-a-om-en.pdf\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"2 Leg Control Applicaitons Blog Article\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" target=\"_blank\"\u003e2 Leg Control Application Blog\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installtion Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installtion Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"16 Amp \/ H3 - U,U² \/ 400VAC","offer_id":40945124343942,"sku":"FE-Thyro S 3S 400-16 H3","price":2164.7,"currency_code":"AUD","in_stock":false},{"title":"30 Amp \/ H3 - U,U² \/ 400VAC","offer_id":40945124376710,"sku":"FE-Thyro S 3S 400-30 H3","price":2154.91,"currency_code":"AUD","in_stock":false},{"title":"45 Amp \/ H3 - U,U² \/ 400VAC","offer_id":40945124409478,"sku":"FE-Thyro S 3S 400-45 H3","price":2872.7,"currency_code":"AUD","in_stock":false},{"title":"60 Amp \/ H3 - U,U² \/ 400VAC","offer_id":40945124442246,"sku":"FE-Thyro S 3S 400-60 H3","price":3722.55,"currency_code":"AUD","in_stock":false},{"title":"100 Amp \/ H3 - U,U² \/ 400VAC","offer_id":40945124475014,"sku":"FE-Thyro S 3S 400-100 H3","price":4197.76,"currency_code":"AUD","in_stock":false},{"title":"130 Amp \/ H3 - U,U² \/ 400VAC","offer_id":40945124507782,"sku":"FE-Thyro S 3S 400-130 HRL3","price":5435.1,"currency_code":"AUD","in_stock":false},{"title":"170 Amp \/ H3 - U,U² \/ 400VAC","offer_id":40945124540550,"sku":"FE-Thyro S 3S 400-170 H3","price":6112.7,"currency_code":"AUD","in_stock":false},{"title":"280 Amp \/ H3 - U,U² \/ 400VAC","offer_id":40945124573318,"sku":"FE-Thyro S 3S 400-280 H3","price":6387.48,"currency_code":"AUD","in_stock":false},{"title":"350 Amp \/ H3 - U,U² \/ 400VAC","offer_id":40945124606086,"sku":"FE-Thyro S 3S 400-350 H3","price":7984.35,"currency_code":"AUD","in_stock":false},{"title":"16 Amp \/ HRL3 - U,U²,I,I² \/ 400VAC","offer_id":40945124638854,"sku":"FE-Thyro S 3S 400-16 HRL3","price":2466.7,"currency_code":"AUD","in_stock":false},{"title":"30 Amp \/ HRL3 - U,U²,I,I² \/ 400VAC","offer_id":40945124671622,"sku":"FE-Thyro S 3S 400-30 HRL3","price":3264.8,"currency_code":"AUD","in_stock":false},{"title":"45 Amp \/ HRL3 - U,U²,I,I² \/ 400VAC","offer_id":40945124704390,"sku":"FE-Thyro S 3S 400-45 HRL3","price":3592.79,"currency_code":"AUD","in_stock":false},{"title":"60 Amp \/ HRL3 - U,U²,I,I² \/ 400VAC","offer_id":40945124737158,"sku":"FE-Thyro S 3S 400-60 HRL3","price":4291.1,"currency_code":"AUD","in_stock":false},{"title":"100 Amp \/ HRL3 - U,U²,I,I² \/ 400VAC","offer_id":40945124769926,"sku":"FE-Thyro S 3S 400-100 HRL3","price":5762.77,"currency_code":"AUD","in_stock":false},{"title":"130 Amp \/ HRL3 - U,U²,I,I² \/ 400VAC","offer_id":40945124802694,"sku":"FE-Thyro S 3S 400-130 HRL3","price":6377.8,"currency_code":"AUD","in_stock":false},{"title":"170 Amp \/ HRL3 - U,U²,I,I² \/ 400VAC","offer_id":40945124835462,"sku":"FE-Thyro S 3S 400-170 HRL3","price":7212.7,"currency_code":"AUD","in_stock":false},{"title":"280 Amp \/ HRL3 - U,U²,I,I² \/ 400VAC","offer_id":40945124868230,"sku":"FE-Thyro S 3S 400-280 HRL3","price":7795.26,"currency_code":"AUD","in_stock":false},{"title":"350 Amp \/ HRL3 - U,U²,I,I² \/ 400VAC","offer_id":40945124900998,"sku":"FE-Thyro S 3S 400-350 HRL3","price":8964.45,"currency_code":"AUD","in_stock":false},{"title":"16 Amp \/ HRLP3 - U,U²,I,I²,P \/ 400VAC","offer_id":40945124933766,"sku":"FE-Thyro S 3S 400-16 HRLP3","price":3545.3,"currency_code":"AUD","in_stock":false},{"title":"30 Amp \/ HRLP3 - U,U²,I,I²,P \/ 400VAC","offer_id":40945124966534,"sku":"FE-Thyro S 3S 400-30 HRLP3","price":4418.7,"currency_code":"AUD","in_stock":false},{"title":"45 Amp \/ HRLP3 - U,U²,I,I²,P \/ 400VAC","offer_id":40945124999302,"sku":"FE-Thyro S 3S 400-45 HRLP3","price":5186.5,"currency_code":"AUD","in_stock":false},{"title":"60 Amp \/ HRLP3 - U,U²,I,I²,P \/ 400VAC","offer_id":40945125032070,"sku":"FE-Thyro S 3S 400-60 HRLP3","price":5491.2,"currency_code":"AUD","in_stock":false},{"title":"100 Amp \/ HRLP3 - U,U²,I,I²,P \/ 400VAC","offer_id":40945125064838,"sku":"FE-Thyro S 3S 400-100 HRLP3","price":6466.9,"currency_code":"AUD","in_stock":false},{"title":"130 Amp \/ HRLP3 - U,U²,I,I²,P \/ 400VAC","offer_id":40945125097606,"sku":"FE-Thyro S 3S 400-130 HRLP3","price":7658.2,"currency_code":"AUD","in_stock":false},{"title":"170 Amp \/ HRLP3 - U,U²,I,I²,P \/ 400VAC","offer_id":40945125130374,"sku":"FE-Thyro S 3S 400-170 HRLP3","price":8534.9,"currency_code":"AUD","in_stock":false},{"title":"280 Amp \/ HRLP3 - U,U²,I,I²,P \/ 400VAC","offer_id":40945125163142,"sku":"FE-Thyro S 3S 400-280 HRLP3","price":9536.67,"currency_code":"AUD","in_stock":false},{"title":"350 Amp \/ HRLP3 - U,U²,I,I²,P \/ 400VAC","offer_id":40945125195910,"sku":"FE-Thyro S 3S 400-350 HRLP3","price":10967.22,"currency_code":"AUD","in_stock":false},{"title":"100 Amp \/ H3 - U,U² \/ 500VAC","offer_id":40945125228678,"sku":"FE-Thyro S 3S 500-100 H3","price":4419.8,"currency_code":"AUD","in_stock":false},{"title":"100 Amp \/ HRLP3 - U,U²,I,I²,P \/ 500VAC","offer_id":40945125261446,"sku":"FE-Thyro S 3S 500-100 HRLP3","price":5435.1,"currency_code":"AUD","in_stock":false},{"title":"130 Amp \/ H3 - U,U² \/ 500VAC","offer_id":40945125294214,"sku":"FE-Thyro S 3S 500-130 HRL3","price":6112.7,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/ThyroA3_0d1f7325-2aff-4a8c-9dc8-6f52dd6f23ae.jpg?v=1714705710"},{"product_id":"thyro-s1s-series-500vac","title":"Thyro S 1S Series Single Phase SCR Controller 16 - 1500Amp 500VAC Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro S 1S Series Single Phase SCR Power Controller, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), SWITCH Operating Modes. Compatible Replacement for Erutotherm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet,Profibus,Ethernet,Modbus Comms\u003c\/li\u003e\n\u003cli\u003e500VAC +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro S 1S 500VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e500VAC +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro A User Manual\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354020\/Advanced%20Energy\/User%20Manuals\/thyro-a-om-en.pdf\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installtion Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installtion Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"16 Amp \/ H3 - U,U² \/ No","offer_id":40945125326982,"sku":"FE-Thyro S 1S 500-16 H3","price":932.5,"currency_code":"AUD","in_stock":false},{"title":"30 Amp \/ H3 - U,U² \/ No","offer_id":40945125359750,"sku":"FE-Thyro S 1S 500-30 H3","price":965.3,"currency_code":"AUD","in_stock":false},{"title":"45 Amp \/ H3 - U,U² \/ No","offer_id":40945125392518,"sku":"FE-Thyro S 1S 500-45 H3","price":1319.7,"currency_code":"AUD","in_stock":false},{"title":"60 Amp \/ H3 - U,U² \/ No","offer_id":40945125425286,"sku":"FE-Thyro S 1S 500-60 H3","price":1489.7,"currency_code":"AUD","in_stock":false},{"title":"100 Amp \/ H3 - U,U² \/ No","offer_id":40945125458054,"sku":"FE-Thyro S 1S 500-100 H3","price":1618.0,"currency_code":"AUD","in_stock":false},{"title":"16 Amp \/ HRL3 - U,U²,I,I² \/ No","offer_id":40945125490822,"sku":"FE-Thyro S 1S 500-16 HRL3","price":1218.0,"currency_code":"AUD","in_stock":false},{"title":"30 Amp \/ HRL3 - U,U²,I,I² \/ No","offer_id":40945125523590,"sku":"FE-Thyro S 1S 500-30 HRL3","price":1391.3,"currency_code":"AUD","in_stock":false},{"title":"45 Amp \/ HRL3 - U,U²,I,I² \/ No","offer_id":40945125556358,"sku":"FE-Thyro S 1S 500-45 HRL3","price":1828.0,"currency_code":"AUD","in_stock":false},{"title":"60 Amp \/ HRL3 - U,U²,I,I² \/ No","offer_id":40945125589126,"sku":"FE-Thyro S 1S 500-60 HRL3","price":1795.7,"currency_code":"AUD","in_stock":false},{"title":"100 Amp \/ HRL3 - U,U²,I,I² \/ No","offer_id":40945125621894,"sku":"FE-Thyro S 1S 500-100 HRL3","price":2332.0,"currency_code":"AUD","in_stock":false},{"title":"16 Amp \/ HRLP3 - U,U²,I,I²,P \/ No","offer_id":40945125654662,"sku":"FE-Thyro S 1S 500-16 HRLP3","price":1477.45,"currency_code":"AUD","in_stock":false},{"title":"30 Amp \/ HRLP3 - U,U²,I,I²,P \/ No","offer_id":40945125687430,"sku":"FE-Thyro S 1S 500-30 HRLP3","price":2009.95,"currency_code":"AUD","in_stock":false},{"title":"45 Amp \/ HRLP3 - U,U²,I,I²,P \/ No","offer_id":40945125720198,"sku":"FE-Thyro S 1S 500-45 HRLP3","price":2179.0,"currency_code":"AUD","in_stock":false},{"title":"60 Amp \/ HRLP3 - U,U²,I,I²,P \/ No","offer_id":40945125752966,"sku":"FE-Thyro S 1S 500-60 HRLP3","price":2289.0,"currency_code":"AUD","in_stock":false},{"title":"100 Amp \/ HRLP3 - U,U²,I,I²,P \/ No","offer_id":40945125785734,"sku":"FE-Thyro S 1S 500-100 HRLP3","price":2882.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_b76acc1b-837e-45ea-9f84-d5993082fe91.jpg?v=1714705656"},{"product_id":"thyro-tool-pro-software-usb","title":"Thyro Tool Pro Software USB - Software for Advanced Energy SCR Controller","description":"\u003ch3\u003e\u003cspan style=\"color: #6ea4d7;\"\u003e\u003cstrong\u003eThyro Tool Pro Software USB - Software for Advanced Energy SCR Controller\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eFor setting up Communication addresses via USB and configuring SCR Controllers Locally or remotely. Highly valueable for controller diagnostics, fault finding and communication validation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1623397864\/Advanced%20Energy\/User%20Manuals\/en-scr-thyro-basic-busmodule-operating-manual.pdf\" title=\"Thyro Tool Pro User Manual\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eBasic Bus User Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installtion Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installtion Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41021777412230,"sku":"FE-Thyro Tool Pro Software USB","price":899.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/ThyroToolPro.jpg?v=1716420788"},{"product_id":"thyro-px-3px-500-170-h","title":"Thyro-PX-3PX-500-170-H, 3 Phase 3 Leg 500VAC SCR Burst\/Phase Fire Power Controller, 170 Amp Per Phase @ 45 Deg C, With Current and Power Control Feedback, Voltage Sequence Control, Switch Operating Mode, MOSI Operating Mode","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-PX-3PX-500-170 H, 3 Phase 3 Leg 500VAC SCR Burst\/Phase Fire Power Controller, 170 Amp Per Phase @ 45 Deg C, With Current and Power Control Feedback, Voltage Sequence Control, Switch Operating Mode, MOSI Operating Mode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e230VAC-500VAC +10\/-20% \u003cspan\u003eLine to Line\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVoltage, Current or Power Control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMolybdenum disilicide Ramp Operating \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustments\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function for Multiple TAKT Sync\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003eArc Furnaces\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMolybdenum Disilicide Elements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSilicon Carbide Elements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eDC Feedback Control from Transformer Secondary\u003c\/li\u003e\n\u003cli\u003eChlorination, Electroplating\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eStart on Short Circuit Load \u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (VAR Mode Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #77a6d9;\"\u003e\u003cstrong\u003eIncorporated Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003ePower Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #7da6d2;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/anybus-module\" title=\"Thyro Series Anybus Module\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eAnybus Module\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px; height: 417.083px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003eThyro-PX-3PX-500-170-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 39.1667px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 39.1667px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e0.5% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e\n\u003cspan\u003e50°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e1 x Inom @ 50 Deg C, 1.1 x Inom @ 40 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003eThree Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 39.1667px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 39.1667px;\"\u003ePhase(VAR), Burst(TAKT), Quick TAKT(QTM), Hybrid(VT on request), MOSI, VSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e170 Amp @ 50 Deg C (110% @ 40 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 19.5833px;\"\u003e\u003cb\u003eRelays \/ Dry Contacts\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 19.5833px;\"\u003e3 Relay Outputs, 3 Dry Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 215.33px;\"\u003e\u003cb\u003eDigital I\/O\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px;\"\u003e6 Digital Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 39.1667px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 39.1667px;\"\u003e(Optional) Conformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e230VAC-500VAC +10\/-20%\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e2.1 to 140kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro PX Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354240\/Advanced%20Energy\/thyro-px-data-sheet.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eBrochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro PX User Manual\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354296\/Advanced%20Energy\/User%20Manuals\/en-scr-thyro-px-operating-manual.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"2 Leg Control Applicaitons Blog Article\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" target=\"_blank\"\u003e2 Leg Control Application Blog\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" title=\"Ethernet IP Setup Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42477056884870,"sku":"FE-Thyro-PX-3PX-500-170-H","price":11900.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/ThyroPX3.jpg?v=1718680028"},{"product_id":"thyro-touch-display","title":"Thyro-Touch Display, TFT Touch Screen for Thyro PX Series SCR Controllers","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy THyro-Touch Display, TFT Touch Screen for Thyro PX Series SCR Controllers\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSwitchable display to bar chart, line chart, actual values, or data logger\u003c\/li\u003e\n\u003cli\u003eIntegrated SD card to load or save data\u003c\/li\u003e\n\u003cli\u003eProcess data recorder of up to 6 parameters as well as status messages\u003c\/li\u003e\n\u003cli\u003eAnalysis via Thyro-Touch tool on PC\u003c\/li\u003e\n\u003cli\u003eEasyStart feature for easy commissioning of Thyro-PX with basic settings\u003c\/li\u003e\n\u003cli\u003eLanguages: German, English (additional options on request)\u003c\/li\u003e\n\u003cli\u003eUL and CE Approved\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitael for Thyro PX\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" title=\"Com Bus Module Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eUser Manual\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1623397864\/Advanced%20Energy\/User%20Manuals\/en-scr-thyro-basic-busmodule-operating-manual.pdf\" title=\"Advance Energy BasicBus model user guide\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eUser Guide\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"Blog\" href=\"\/blogs\/power-controllers\/setting-up-the-advanced-energy-basicbus-module-for-string-communications-of-thyro-pcm-scr-controllers\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eBlog for initial communication setup issue\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" title=\"Ethernet IP Setup Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41273638649990,"sku":"FE-Thyro-Touch Display","price":789.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/ThyroTouchDisplay.jpg?v=1722498725"},{"product_id":"thyro-px-3px-500-1250-hf-dc-1250-amp-dc-output-45-deg-c-with-current-and-power-control-feedback","title":"Thyro-PX-3PX-500-1250-H-F-DC, Controller Rectifier 1250 Amp DC Output @ 45 Deg C, With Current and Power Control Feedback","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Controller Rectifier Thyro-PX-3PX-500-1250-H-F-DC, Controller Rectifier 1250 Amp DC Output @ 45 Deg C, With Current and Power Control Feedback\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e230VAC-500VAC +10\/-20% \u003cspan\u003eLine to Line Input\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVoltage, Current or Power Control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustments\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function for Multiple TAKT Sync\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eArc Furnaces\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSilicon Carbide Elements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eDC Feedback Control from Transformer Secondary\u003c\/li\u003e\n\u003cli\u003eChlorination, Electroplating\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eStart on Short Circuit Load \u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (VAR Mode Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #77a6d9;\"\u003e\u003cstrong\u003eIncorporated Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003ePower Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #7da6d2;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Series Anybus Module\" href=\"\/products\/anybus-module\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eAnybus Module\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px; height: 455.833px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003eThyro-PX-3PX-500-1250-H-F-DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 39.1667px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 39.1667px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e0.5% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e\n\u003cspan\u003e50°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003eInom @ 50 Deg C, 1.1 x Inom @ 40 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003eThree Phase Bridge B6U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 39.1667px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 39.1667px;\"\u003ePhase(VAR), Burst(TAKT), Quick TAKT(QTM), Hybrid(VT on request), MOSI, VSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 39.1667px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 39.1667px;\"\u003e1250 Amp DC @ 50 Deg C (+10% @ 40 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 19.5833px;\"\u003e\u003cb\u003eRelays \/ Dry Contacts\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 19.5833px;\"\u003e3 Relay Outputs, 3 Dry Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 19.5833px;\"\u003e\u003cb\u003eDigital I\/O\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 19.5833px;\"\u003e6 Digital Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 39.1667px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 39.1667px;\"\u003e(Optional) Conformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e230VAC-500VAC +10\/-20%\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e110kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354240\/Advanced%20Energy\/thyro-px-data-sheet.pdf\" title=\"Thyro PX Brochure\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354296\/Advanced%20Energy\/User%20Manuals\/en-scr-thyro-px-operating-manual.pdf\" title=\"Thyro PX User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" style=\"color: #2b00ff;\" target=\"_blank\"\u003e2 Leg Control Application Blog\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installtion Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41299352649862,"sku":"FE-Thyro-PX-3PX-500-1250-H-F-DC","price":41879.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/ThyroPX3_cb1ecbfc-4803-43c4-82b2-895dd4477881.jpg?v=1723792020"},{"product_id":"thyro-px-3px-500-1000-hf-dc","title":"Thyro-PX-3PX-500-1000-H-F-DC, Controller Rectifier 1000 Amp DC Output @ 50 Deg C, With Current and Power Control Feedback","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-PX-3PX-500-1000-H-F-DC, Controller Rectifier 1000 Amp DC Output @ 50 Deg C, With Current and Power Control Feedback\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e230VAC-500VAC +10\/-20% \u003cspan\u003eLine to Line Input\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVoltage, Current or Power Control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustments\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function for Multiple TAKT Sync\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eArc Furnaces\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSilicon Carbide Elements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eDC Feedback Control from Transformer Secondary\u003c\/li\u003e\n\u003cli\u003eChlorination, Electroplating\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eStart on Short Circuit Load \u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (VAR Mode Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #77a6d9;\"\u003e\u003cstrong\u003eIncorporated Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003ePower Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #7da6d2;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Series Anybus Module\" href=\"\/products\/anybus-module\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eAnybus Module\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px; height: 417.083px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003eThyro-PX 3PX 500-1000 HF DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 39.1667px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 39.1667px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e0.5% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e\n\u003cspan\u003e50°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003eInom @ 50 Deg C, 1.1 x Inom @ 40 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003eThree Phase Bridge B6U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 39.1667px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 39.1667px;\"\u003ePhase(VAR), Burst(TAKT), Quick TAKT(QTM), Hybrid(VT on request), MOSI, VSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e1000 Amp DC @ 50 Deg C (+10% @ 40 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 19.5833px;\"\u003e\u003cb\u003eRelays \/ Dry Contacts\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 19.5833px;\"\u003e3 Relay Outputs, 3 Dry Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 215.33px;\"\u003e\u003cb\u003eDigital I\/O\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px;\"\u003e6 Digital Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 39.1667px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 39.1667px;\"\u003e(Optional) Conformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e230VAC-500VAC +10\/-20%\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e110kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 215.33px; height: 20px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354240\/Advanced%20Energy\/thyro-px-data-sheet.pdf\" title=\"Thyro PX Brochure\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354296\/Advanced%20Energy\/User%20Manuals\/en-scr-thyro-px-operating-manual.pdf\" title=\"Thyro PX User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/fastron-electronics-store.myshopify.com\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" title=\"2 Leg Control Applicaitons Blog Article\" style=\"color: #2b00ff;\" target=\"_blank\"\u003e2 Leg Control Application Blog\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installtion Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41299352977542,"sku":"FE-Thyro-PX-3PX-500-1000-H-F-DC","price":37506.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/ThyroPX3_cb1ecbfc-4803-43c4-82b2-895dd4477881.jpg?v=1723792020"},{"product_id":"thyro-px-3px-500-1800-hf-dc","title":"Thyro-PX-3PX-500-1800-H-F-DC, Controller Rectifier 1800 Amp DC Output @ 50 Deg C, With Current and Power Control Feedback","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Controller Rectifier Thyro-PX-3PX-500-1800-H-F-DC, Controller Rectifier 1800 Amp DC Output @ 50 Deg C, With Current and Power Control Feedback\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e230VAC-500VAC +10\/-20% \u003cspan\u003eLine to Line Input\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVoltage, Current or Power Control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuses\u003c\/li\u003e\n\u003cli\u003e3 Phase, Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustments\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function for Multiple TAKT Sync\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eArc Furnaces\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSilicon Carbide Elements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eDC Feedback Control from Transformer Secondary\u003c\/li\u003e\n\u003cli\u003eChlorination, Electroplating\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eStart on Short Circuit Load \u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (VAR Mode Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #77a6d9;\"\u003e\u003cstrong\u003eIncorporated Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003ePower Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #7da6d2;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/anybus-module\" title=\"Thyro Series Anybus Module\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eAnybus Module\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px; height: 417.083px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003eThyro-PX-3PX-500-1800-H-F-DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 39.1667px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 39.1667px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e0.5% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e\n\u003cspan\u003e50°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e1 x Inom @ 50 Deg C, 1.1 x Inom @ 40 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003eThree Phase Bridge B6U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 39.1667px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 39.1667px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request), MOSI, VSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e1800 Amp DC @ 50 Deg C (+10% @ 40 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 19.5833px;\"\u003e\u003cb\u003eRelays \/ Dry Contacts\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 19.5833px;\"\u003e3 Relay Outputs, 3 Dry Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 215.33px;\"\u003e\u003cb\u003eDigital I\/O\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px;\"\u003e6 Digital Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 39.1667px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 39.1667px;\"\u003e(Optional) Conformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e230VAC-500VAC +10\/-20%\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e110kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 20px;\"\u003e\n\u003ctd style=\"width: 215.33px; height: 20px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 310.99px; height: 20px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro PX Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354240\/Advanced%20Energy\/thyro-px-data-sheet.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eBrochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro PX User Manual\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354296\/Advanced%20Energy\/User%20Manuals\/en-scr-thyro-px-operating-manual.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"2 Leg Control Applicaitons Blog Article\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/blogs\/power-controllers\/2-leg-burst-fire-scr-control-advantages\" target=\"_blank\"\u003e2 Leg Control Application Blog\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installtion Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" title=\"Ethernet IP Setup Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41299354124422,"sku":"FE-Thyro-PX-3PX-500-1800-H-F-DC","price":50363.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/ThyroPX3_4ea71bf8-3756-45d3-99fc-6c20ac13f822.jpg?v=1723792555"},{"product_id":"2-000-190-015","title":"Ethernet IP Anybus Module, Comms Interface for Thyro PX or Basic Bus Module","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy Ethernet IP Anybus Module, Comms Interface for Thyro PX or Basic Bus Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Connection for up to 8 Power Controllers with 8 Modules\u003c\/li\u003e\n\u003cli\u003eFor Thyro PX or Basic Bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #86b0d4;\"\u003e\u003cstrong\u003eCommunication Options :\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet\/IP\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfibus DPV1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModbus RTU\u003c\/li\u003e\n\u003cli\u003eModbus TCP\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfiNET\u003c\/li\u003e\n\u003cli\u003eEtherCAT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 530px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Numbers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eEthernetIP(2.000.090.015)\u003cbr\u003eProfiNET(2.000.190.011)\u003cbr\u003eModbusTCP(2.000.190.013)\u003cbr\u003eProfibusDPV1(2.000.190.010) ModbusRTU(2.000.190.012) DeviceNet(2.000.190.0014)\u003cbr\u003eEtherCAT(2.000.190.016)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e(Via Basic Bus or Thyro PX) Access to controller setpoints, actual points, and parameters\u003cbr\u003eTransfer of setpoints as float number in physical units\u003cbr\u003eControl Function of LED's\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan\u003eEthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet, EtherCat, Modbus RTU\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cb\u003eApprovals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eCE, UL\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e-20 ???? ??C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e??\u003c\/p\u003e\n\u003ch5\u003eDatasheet and Guides\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Com Bus Module Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41601384743046,"sku":"FE-2.000.190.015","price":577.5,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/dASM_99f22db9-c7b4-48e1-a629-56e3b2b48095.jpg?v=1740034269"},{"product_id":"2-000-190-012","title":"Modbus RTU Anybus Module, Comms Interface for Thyro PX or Basic Bus Module","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy Modbus RTU Anybus Module, Comms Interface for Thyro PX or Basic Bus Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Connection for up to 8 Power Controllers with 8 Modules\u003c\/li\u003e\n\u003cli\u003eFor Thyro PX or Basic Bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #86b0d4;\"\u003e\u003cstrong\u003eCommunication Options :\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet\/IP\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfibus DPV1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModbus RTU\u003c\/li\u003e\n\u003cli\u003eModbus TCP\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfiNET\u003c\/li\u003e\n\u003cli\u003eEtherCAT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 530px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Numbers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eEthernetIP(2.000.090.015)\u003cbr\u003eProfiNET(2.000.190.011)\u003cbr\u003eModbusTCP(2.000.190.013)\u003cbr\u003eProfibusDPV1(2.000.190.010) ModbusRTU(2.000.190.012) DeviceNet(2.000.190.0014)\u003cbr\u003eEtherCAT(2.000.190.016)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e(Via Basic Bus or Thyro PX) Access to controller setpoints, actual points, and parameters\u003cbr\u003eTransfer of setpoints as float number in physical units\u003cbr\u003eControl Function of LED's\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan\u003eEthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet, EtherCat, Modbus RTU\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cb\u003eApprovals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eCE, UL\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e-20 ???? ??C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e??\u003c\/p\u003e\n\u003ch5\u003eDatasheet and Guides\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Com Bus Module Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41601384775814,"sku":"FE-2.000.190.012","price":577.5,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/dASM_9beb162c-e086-4086-a1e2-35ecc5abca24.jpg?v=1740034271"},{"product_id":"2-000-190-013","title":"Modbus TCP Anybus Module, Comms Interface for Thyro PX or Basic Bus Module","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy Modbus TCP Anybus Module, Comms Interface for Thyro PX or Basic Bus Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Connection for up to 8 Power Controllers with 8 Modules\u003c\/li\u003e\n\u003cli\u003eFor Thyro PX or Basic Bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #86b0d4;\"\u003e\u003cstrong\u003eCommunication Options :\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet\/IP\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfibus DPV1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModbus RTU\u003c\/li\u003e\n\u003cli\u003eModbus TCP\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfiNET\u003c\/li\u003e\n\u003cli\u003eEtherCAT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 530px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Numbers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eEthernetIP(2.000.090.015)\u003cbr\u003eProfiNET(2.000.190.011)\u003cbr\u003eModbusTCP(2.000.190.013)\u003cbr\u003eProfibusDPV1(2.000.190.010) ModbusRTU(2.000.190.012) DeviceNet(2.000.190.0014)\u003cbr\u003eEtherCAT(2.000.190.016)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e(Via Basic Bus or Thyro PX) Access to controller setpoints, actual points, and parameters\u003cbr\u003eTransfer of setpoints as float number in physical units\u003cbr\u003eControl Function of LED's\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan\u003eEthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet, EtherCat, Modbus RTU\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cb\u003eApprovals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eCE, UL\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e-20 ???? ??C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e??\u003c\/p\u003e\n\u003ch5\u003eDatasheet and Guides\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Com Bus Module Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41601384841350,"sku":"FE-2.000.190.013","price":577.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/dASM_d571ded7-1794-435d-bf1f-52346cd3258e.jpg?v=1740034273"},{"product_id":"2-000-190-011","title":"Profinet Anybus Module, Comms Interface for Thyro PX or Basic Bus Module","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy Profinet Anybus Module, Comms Interface for Thyro PX or Basic Bus Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Connection for up to 8 Power Controllers with 8 Modules\u003c\/li\u003e\n\u003cli\u003eFor Thyro PX or Basic Bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #86b0d4;\"\u003e\u003cstrong\u003eCommunication Options :\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet\/IP\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfibus DPV1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModbus RTU\u003c\/li\u003e\n\u003cli\u003eModbus TCP\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfiNET\u003c\/li\u003e\n\u003cli\u003eEtherCAT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 530px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Numbers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eEthernetIP(2.000.090.015)\u003cbr\u003eProfiNET(2.000.190.011)\u003cbr\u003eModbusTCP(2.000.190.013)\u003cbr\u003eProfibusDPV1(2.000.190.010) ModbusRTU(2.000.190.012) DeviceNet(2.000.190.0014)\u003cbr\u003eEtherCAT(2.000.190.016)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e(Via Basic Bus or Thyro PX) Access to controller setpoints, actual points, and parameters\u003cbr\u003eTransfer of setpoints as float number in physical units\u003cbr\u003eControl Function of LED's\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan\u003eEthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet, EtherCat, Modbus RTU\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cb\u003eApprovals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eCE, UL\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e-20 ???? ??C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e??\u003c\/p\u003e\n\u003ch5\u003eDatasheet and Guides\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Com Bus Module Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41601384874118,"sku":"FE-2.000.190.011","price":777.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/dASM.jpg?v=1740034274"},{"product_id":"2-000-190-010","title":"Profibus Anybus Module, Comms Interface for Thyro PX or Basic Bus Module","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy Profibus Anybus Module, Comms Interface for Thyro PX or Basic Bus Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Connection for up to 8 Power Controllers with 8 Modules\u003c\/li\u003e\n\u003cli\u003eFor Thyro PX or Basic Bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #86b0d4;\"\u003e\u003cstrong\u003eCommunication Options :\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet\/IP\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfibus DPV1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModbus RTU\u003c\/li\u003e\n\u003cli\u003eModbus TCP\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfiNET\u003c\/li\u003e\n\u003cli\u003eEtherCAT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 530px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Numbers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eEthernetIP(2.000.090.015)\u003cbr\u003eProfiNET(2.000.190.011)\u003cbr\u003eModbusTCP(2.000.190.013)\u003cbr\u003eProfibusDPV1(2.000.190.010) ModbusRTU(2.000.190.012) DeviceNet(2.000.190.0014)\u003cbr\u003eEtherCAT(2.000.190.016)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e(Via Basic Bus or Thyro PX) Access to controller setpoints, actual points, and parameters\u003cbr\u003eTransfer of setpoints as float number in physical units\u003cbr\u003eControl Function of LED's\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan\u003eEthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet, EtherCat, Modbus RTU\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cb\u003eApprovals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eCE, UL\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e-20  to 70C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet and Guides\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Com Bus Module Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41601384906886,"sku":"FE-2.000.190.010","price":577.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/dASM_1683092d-0698-4410-a55f-e961f5eaa5ac.jpg?v=1740034276"},{"product_id":"2-000-190-014","title":"DeviceNet Anybus Module, Comms Interface for Thyro PX or Basic Bus Module","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy DeviceNet Anybus Module, Comms Interface for Thyro PX or Basic Bus Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Connection for up to 8 Power Controllers with 8 Modules\u003c\/li\u003e\n\u003cli\u003eFor Thyro PX or Basic Bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #86b0d4;\"\u003e\u003cstrong\u003eCommunication Options :\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet\/IP\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfibus DPV1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModbus RTU\u003c\/li\u003e\n\u003cli\u003eModbus TCP\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfiNET\u003c\/li\u003e\n\u003cli\u003eEtherCAT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 530px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Numbers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eEthernetIP(2.000.090.015)\u003cbr\u003eProfiNET(2.000.190.011)\u003cbr\u003eModbusTCP(2.000.190.013)\u003cbr\u003eProfibusDPV1(2.000.190.010) ModbusRTU(2.000.190.012) DeviceNet(2.000.190.0014)\u003cbr\u003eEtherCAT(2.000.190.016)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e(Via Basic Bus or Thyro PX) Access to controller setpoints, actual points, and parameters\u003cbr\u003eTransfer of setpoints as float number in physical units\u003cbr\u003eControl Function of LED's\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan\u003eEthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet, EtherCat, Modbus RTU\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cb\u003eApprovals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eCE, UL\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e-20 ???? ??C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e??\u003c\/p\u003e\n\u003ch5\u003eDatasheet and Guides\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Com Bus Module Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41601384972422,"sku":"FE-2.000.190.014","price":577.5,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/dASM_edb23497-4acd-4c70-baa9-e71f981d1d1c.jpg?v=1740034278"},{"product_id":"2-000-190-016","title":"EtherCAT Anybus Module, Comms Interface for Thyro PX or Basic Bus Module","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy EtherCAT Anybus Module, Comms Interface for Thyro PX or Basic Bus Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Connection for up to 8 Power Controllers with 8 Modules\u003c\/li\u003e\n\u003cli\u003eFor Thyro PX or Basic Bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #86b0d4;\"\u003e\u003cstrong\u003eCommunication Options :\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet\/IP\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfibus DPV1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModbus RTU\u003c\/li\u003e\n\u003cli\u003eModbus TCP\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfiNET\u003c\/li\u003e\n\u003cli\u003eEtherCAT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 530px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Numbers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eEthernetIP(2.000.090.015)\u003cbr\u003eProfiNET(2.000.190.011)\u003cbr\u003eModbusTCP(2.000.190.013)\u003cbr\u003eProfibusDPV1(2.000.190.010) ModbusRTU(2.000.190.012) DeviceNet(2.000.190.0014)\u003cbr\u003eEtherCAT(2.000.190.016)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e(Via Basic Bus or Thyro PX) Access to controller setpoints, actual points, and parameters\u003cbr\u003eTransfer of setpoints as float number in physical units\u003cbr\u003eControl Function of LED's\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan\u003eEthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet, EtherCat, Modbus RTU\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cb\u003eApprovals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eCE, UL\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e-20 ???? ??C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e??\u003c\/p\u003e\n\u003ch5\u003eDatasheet and Guides\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" title=\"Com Bus Module Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" title=\"Ethernet IP Setup Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41601385037958,"sku":"FE-2.000.190.016","price":577.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/dASM_41f49ea0-7e32-4623-a961-096acf17cde4.jpg?v=1740034280"},{"product_id":"thyro-a-1a-230-16-h3","title":"Thyro-A-1A-230-16-H3, Thyro-A-1A-Series Single Phase SCR Controller 16Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_16 Amp","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eThyro-A-1A-230-16-H3, Thyro-A-1A-Series Single Phase SCR Controller 16Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_16 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet, Profibus, Ethernet, Modbus Comms\u003c\/li\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control, +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-230-16-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control, +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476915949702,"sku":"FE-Thyro A 1A 230-16 H3","price":669.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_719d4f04-c952-4432-9a63-46726f6f22d8.jpg?v=1759459712"},{"product_id":"thyro-eco-a1a-400-25-e-l3","title":"Thyro ECO A1A 400-25 E L3, Thyro-A-1A-ECO Series Single Phase SCR Controller 25 Amp 230VAC +10%\/-57%, Voltage Control only, Phase(VAR), Burst(TAKT), Switch Operating Mode","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro A 1A ECO Series 3 Phase SCR Power Controller, 230VAC +10%\/-57%, Voltage Control only, 25 to 125 Amp Ratings, Phase(VAR), Burst(TAKT), SWITCH Operating Modes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control only +10\/-57% Voltage Control\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e3 Phase, Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eFully enclosed IP20\u003c\/li\u003e\n\u003cli\u003ePhase Angle(VAR), and Burst Fire(TAKT) switching\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function\u003c\/li\u003e\n\u003cli\u003eDigital Alarm Output\u003c\/li\u003e\n\u003cli\u003eLoad Monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSpecial Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEconomic Model\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro A 1A ECO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3 Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e25 to 125 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control only +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 10kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Thyro A ECO Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584353889\/Advanced%20Energy\/en-scr-thyro-a-eco-data-sheet.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eBrochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro A User Manual\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354020\/Advanced%20Energy\/User%20Manuals\/thyro-a-om-en.pdf\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476915982470,"sku":"FE-Thyro ECO A1A 400-25 E L3","price":887.04,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_dfd1f03f-42a6-4bc6-ac43-7ebc4927648d.jpg?v=1759459818"},{"product_id":"thyro-a-1a-500-16-h3","title":"Thyro-A-1A-500-16-H3, Thyro-A-1A-Series Single Phase SCR Controller 16Amp 500VAC Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Thyro-A-1A-500-16-H3, Thyro-A-1A-Series Single Phase SCR Controller 16Amp 500VAC Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet,Profibus,Ethernet,Modbus Comms\u003c\/li\u003e\n\u003cli\u003e500VAC +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"thyro-bus-module\" title=\"Thyro Series Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"basic-bus-module\" title=\"Basic Bus Module\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 533px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-500-16-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e500VAC +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 217px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" title=\"Thyro A Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" title=\"Thyro A Series Quick Installation Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" title=\"Ethernet IP Setup Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476916015238,"sku":"FE-Thyro A 1A 500-16 H3","price":932.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_65835914-b1a6-4213-acaf-7fce42bb869f.jpg?v=1759459836"},{"product_id":"thyro-a-1a-230-30-h3","title":"Thyro-A-1A-230-30-H3, Thyro-A-1A-Series Single Phase SCR Controller 30Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_30 Amp","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eThyro-A-1A-230-30-H3, Thyro-A-1A-Series Single Phase SCR Controller 30Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_30 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet, Profibus, Ethernet, Modbus Comms\u003c\/li\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control, +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-230-30-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control, +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476916703366,"sku":"FE-Thyro A 1A 230-30 H3","price":837.6,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_3d4daea9-1b83-43d3-9aad-c8c2236a0f9b.jpg?v=1759459716"},{"product_id":"thyro-a-1a-230-45-h3","title":"Thyro-A-1A-230-45-H3, Thyro-A-1A-Series Single Phase SCR Controller 45Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_45 Amp","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eThyro-A-1A-230-45-H3, Thyro-A-1A-Series Single Phase SCR Controller 45Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_45 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet, Profibus, Ethernet, Modbus Comms\u003c\/li\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control, +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-230-45-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control, +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476916736134,"sku":"FE-Thyro A 1A 230-45 H3","price":965.45,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_12ddf061-63b5-4075-b8ad-d2470c848e76.jpg?v=1759459721"},{"product_id":"thyro-a-1a-230-60-h3","title":"Thyro-A-1A-230-60-H3, Thyro-A-1A-Series Single Phase SCR Controller 60Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_60 Amp","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eThyro-A-1A-230-60-H3, Thyro-A-1A-Series Single Phase SCR Controller 60Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_60 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet, Profibus, Ethernet, Modbus Comms\u003c\/li\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control, +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-230-60-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control, +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476916768902,"sku":"FE-Thyro A 1A 230-60 H3","price":1015.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_134cdf19-8c01-43cd-97d7-1b21db82deca.jpg?v=1759459727"},{"product_id":"thyro-a-1a-230-100-h3","title":"Thyro-A-1A-230-100-H3, Thyro-A-1A-Series Single Phase SCR Controller 100Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_100 Amp","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eThyro-A-1A-230-100-H3, Thyro-A-1A-Series Single Phase SCR Controller 100Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_100 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet, Profibus, Ethernet, Modbus Comms\u003c\/li\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control, +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-230-100-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control, +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476916801670,"sku":"FE-Thyro A 1A 230-100 H3","price":1517.12,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_6d242ee6-36d3-44b9-8484-9ac307850b8e.jpg?v=1759459731"},{"product_id":"thyro-a-1a-230-130-h3","title":"Thyro-A-1A-230-130-H3, Thyro-A-1A-Series Single Phase SCR Controller 130Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_130 Amp","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eThyro-A-1A-230-130-H3, Thyro-A-1A-Series Single Phase SCR Controller 130Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_130 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet, Profibus, Ethernet, Modbus Comms\u003c\/li\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control, +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-230-130-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control, +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476916834438,"sku":"FE-Thyro A 1A 230-130 H3","price":1834.8,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_fb0b5efb-f59d-4879-920f-683e2b58adaa.jpg?v=1759459735"},{"product_id":"thyro-a-1a-230-170-h3","title":"Thyro-A-1A-230-170-H3, Thyro-A-1A-Series Single Phase SCR Controller 170Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_170 Amp","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eThyro-A-1A-230-170-H3, Thyro-A-1A-Series Single Phase SCR Controller 170Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_170 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet, Profibus, Ethernet, Modbus Comms\u003c\/li\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control, +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-230-170-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control, +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476916867206,"sku":"FE-Thyro A 1A 230-170 H3","price":2042.7,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_30092fa2-c7cc-4f4f-9eea-063ff166e3a5.jpg?v=1759459738"},{"product_id":"thyro-a-1a-230-280-h3","title":"Thyro-A-1A-230-280-H3, Thyro-A-1A-Series Single Phase SCR Controller 280Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_280 Amp","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eThyro-A-1A-230-280-H3, Thyro-A-1A-Series Single Phase SCR Controller 280Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_280 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet, Profibus, Ethernet, Modbus Comms\u003c\/li\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control, +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-230-280-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control, +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476916899974,"sku":"FE-Thyro A 1A 230-280 H3","price":2483.8,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_3f2c5ceb-b152-41ee-b763-47e26accc7f2.jpg?v=1759459742"},{"product_id":"thyro-a-1a-230-350-h3","title":"Thyro-A-1A-230-350-H3, Thyro-A-1A-Series Single Phase SCR Controller 350Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_350 Amp","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eThyro-A-1A-230-350-H3, Thyro-A-1A-Series Single Phase SCR Controller 350Amp 230VAC +10%\/-57%, Voltage Control,  Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_350 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet, Profibus, Ethernet, Modbus Comms\u003c\/li\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control, +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-230-350-H3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control, +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476916965510,"sku":"FE-Thyro A 1A 230-350 H3","price":2954.6,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_3818987b-5fda-42eb-a304-5a4103c803b0.jpg?v=1759459746"},{"product_id":"thyro-a-1a-230-16-hrl3","title":"Thyro-A-1A-230-16-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 16Amp 230VAC +10%\/-57%, Voltage Control, Current Feedback Option, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_16 Amp","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eThyro-A-1A-230-16-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 16Amp 230VAC +10%\/-57%, Voltage Control, Current Feedback Option, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_16 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet, Profibus, Ethernet, Modbus Comms\u003c\/li\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control, +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-230-16-H-RL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control, +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476916998278,"sku":"FE-Thyro A 1A 230-16 HRL3","price":883.15,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_bd5df0d6-c3bc-4266-b6df-56c316e0643b.jpg?v=1759459749"},{"product_id":"thyro-a-1a-230-30-hrl3","title":"Thyro-A-1A-230-30-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 30Amp 230VAC +10%\/-57%, Voltage Control, Current Feedback Option, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_30 Amp","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eThyro-A-1A-230-30-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 30Amp 230VAC +10%\/-57%, Voltage Control, Current Feedback Option, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_30 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet, Profibus, Ethernet, Modbus Comms\u003c\/li\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control, +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-230-30-H-RL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control, +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476917031046,"sku":"FE-Thyro A 1A 230-30 HRL3","price":1178.8,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_41cfd1fa-a6d7-4d94-b164-fe41e3f7aace.jpg?v=1759459753"},{"product_id":"thyro-a-1a-230-45-hrl3","title":"Thyro-A-1A-230-45-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 45Amp 230VAC +10%\/-57%, Voltage Control, Current Feedback Option, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_45 Amp","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eThyro-A-1A-230-45-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 45Amp 230VAC +10%\/-57%, Voltage Control, Current Feedback Option, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_45 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet, Profibus, Ethernet, Modbus Comms\u003c\/li\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control, +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-230-45-H-RL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control, +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476917063814,"sku":"FE-Thyro A 1A 230-45 HRL3","price":1157.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_6683f01e-27f8-49cd-9fd1-77d1c8d5c126.jpg?v=1759459757"},{"product_id":"thyro-a-1a-230-60-hrl3","title":"Thyro-A-1A-230-60-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 60Amp 230VAC +10%\/-57%, Voltage Control, Current Feedback Option, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_60 Amp","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eThyro-A-1A-230-60-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 60Amp 230VAC +10%\/-57%, Voltage Control, Current Feedback Option, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_60 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet, Profibus, Ethernet, Modbus Comms\u003c\/li\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control, +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-230-60-H-RL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control, +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476917096582,"sku":"FE-Thyro A 1A 230-60 HRL3","price":1319.3,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_05c9202b-a7be-44f6-b561-42820b1a7401.jpg?v=1759459760"},{"product_id":"thyro-a-1a-230-100-hrl3","title":"Thyro-A-1A-230-100-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 100Amp 230VAC +10%\/-57%, Voltage Control, Current Feedback Option, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_100 Amp","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eThyro-A-1A-230-100-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 100Amp 230VAC +10%\/-57%, Voltage Control, Current Feedback Option, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Current_100 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet, Profibus, Ethernet, Modbus Comms\u003c\/li\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control, +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-230-100-H-RL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control, +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476917129350,"sku":"FE-Thyro A 1A 230-100 HRL3","price":1868.45,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_a745ebd5-3691-4786-94f8-595a1be6b9e1.jpg?v=1759459764"},{"product_id":"thyro-a-1a-230-130-hrl3","title":"Thyro-A-1A-230-130-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 130Amp 230VAC +10%\/-57%, Voltage Control, Current Feedback Option, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eThyro-A-1A-230-130-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 130Amp 230VAC +10%\/-57%, Voltage Control, Current Feedback Option, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet, Profibus, Ethernet, Modbus Comms\u003c\/li\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control, +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-230-130-H-RL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control, +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476917162118,"sku":"FE-Thyro A 1A 230-130 HRL3","price":2161.5,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_5f624aae-e670-438c-a5a1-25a40f44a041.jpg?v=1759459767"},{"product_id":"thyro-a-1a-230-170-hrl3","title":"Thyro-A-1A-230-170-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 170Amp 230VAC +10%\/-57%, Voltage Control, Current Feedback Option, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eThyro-A-1A-230-170-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 170Amp 230VAC +10%\/-57%, Voltage Control, Current Feedback Option, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet, Profibus, Ethernet, Modbus Comms\u003c\/li\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control, +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-230-170-H-RL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control, +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476917653638,"sku":"FE-Thyro A 1A 230-170 HRL3","price":2426.6,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_eef478cb-5ddb-4b07-82ab-fb8247955b0c.jpg?v=1759459771"},{"product_id":"thyro-a-1a-230-280-hrl3","title":"Thyro-A-1A-230-280-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 280Amp 230VAC +10%\/-57%, Voltage Control, Current Feedback Option, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eThyro-A-1A-230-280-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 280Amp 230VAC +10%\/-57%, Voltage Control, Current Feedback Option, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Profinet, Profibus, Ethernet, Modbus Comms\u003c\/li\u003e\n\u003cli\u003e230VAC +10%\/-57%, Voltage Control, +10\/-57% Voltage, Current or Power Control\u003c\/li\u003e\n\u003cli\u003eBuilt in Fuse\u003c\/li\u003e\n\u003cli\u003eSmallest footprint on the market \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle Phase Phase Angle \u0026amp; Burst Controller with SWITCH operation mode\u003c\/li\u003e\n\u003cli\u003eSWITCH between Phase(VAR) or Burst(TAKT) control modes\u003c\/li\u003e\n\u003cli\u003eQuick TAKT Mode (QTM), VT Mode (on request)\u003c\/li\u003e\n\u003cli\u003e(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control\u003c\/li\u003e\n\u003cli\u003eRemovable Cover\u003c\/li\u003e\n\u003cli\u003ePotentiometer Adjustment\u003c\/li\u003e\n\u003cli\u003eUSB Configuration\/Bias Setting\u003c\/li\u003e\n\u003cli\u003eSynchronisation Function (dASM Module Recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Ovens, Kilns, or Furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Control of Transformer Loads in Phase or Burst Fire mode\u003c\/li\u003e\n\u003cli\u003eAC Soft Starter (Combined with PLC)\u003c\/li\u003e\n\u003cli\u003ePower Regulation Applications\u003c\/li\u003e\n\u003cli\u003eElectric Boilers\u003c\/li\u003e\n\u003cli\u003eBrewery Heating\u003c\/li\u003e\n\u003cli\u003eIndustrial Light Dimming\u003c\/li\u003e\n\u003cli\u003eSuitable for extreme environments such as mining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eSeries Optional Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRL\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCurrent Control\/Feedback\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eProgrammable Relay Alarm Output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLoad Monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAnalogue Output\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFor HRLP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAs above with Power Control Feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #77abd6;\"\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Thyro Series Bus Module\" href=\"thyro-bus-module\" target=\"_blank\"\u003eStandard Thyro Bus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Basic Bus Module\" href=\"basic-bus-module\" target=\"_blank\"\u003eBasicBus Module\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 533px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eThyro-A-1A-230-280-H-RL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eCE, UL508A, EU Directive 2014\/35\/EU \u0026amp; 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e3% at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eRated Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e\n\u003cspan\u003e45°\u003c\/span\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTemperature Derating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSCR Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eSingle Phase AC Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePhase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e4(0)-20mA, 0(1)-5V, 0(2)-10V, POT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eLoad Current \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eControl Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e0-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eOptions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eConformal Coating for Gas or High Humidity Environments\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e230VAC +10%\/-57%, Voltage Control, +10\/-15% (-57% with 24VDC Aux Supply)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cb\u003eSoft Start\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eVia PLC input\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e2.1 to 30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 217px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 314px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical Docs\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003e\u003ca title=\"Thyro A Brochure\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1584354097\/Advanced%20Energy\/en-scr-thyro-a-data-sheet.pdf\" style=\"color: #2b00ff;\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1624606194\/Advanced%20Energy\/User%20Manuals\/thyro-a-h3-operating-manual_2018.pdf\" title=\"Thyro A User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Thyro A Series Quick Installation Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348063\/Advanced%20Energy\/Thyro_A_Series_Quick_Installation_Guide.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro A Series Quick Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":42476917686406,"sku":"FE-Thyro A 1A 230-280 HRL3","price":3038.2,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/thyroa-041a-fl-wp_576641cb-d1c8-4a86-b8da-350381cf5e22.jpg?v=1759459775"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/collections\/download_2.jpg?v=1585461468","url":"https:\/\/fastron.com.au\/collections\/phase-angle-power-controllers.oembed?page=3","provider":"Fastron Electronics Store ","version":"1.0","type":"link"}