{"title":"LEM Price Group #14","description":"For Tiered pricing only","products":[{"product_id":"la205-s","title":"LA 205-S, C\/L Hall Effect Current Sensor, 200 Amp, 100mA Output, 23 x 18mm Aperture, +\/-12..18V Supply, Panel Mount, X = 0.8%","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LA 205-S Closed Loop AC\/DC Hall Effect Sensor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 100kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eClosed\u003c\/span\u003e loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003ePanel Mount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLA205-S\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 x 23mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-12..15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-300 Amp \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3.25 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolex series 5046 4 pins\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1532671567\/LEM\/Datasheets\/LA_205-S_Data_Sheet_2006.05.pdf\" target=\"_blank\" title=\"LEM LA 205-S Series\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003e\u003cspan\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\" title=\"LEM Application Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":10288337649779,"sku":"FE-LA205-S","price":189.18,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-la-205-s-c-l-hall-effect-current-sensor-200-amp-100ma-output-23-x-18mm-aperture-12-18v-supply-panel-mount-x-0-8-12080278700147.jpg?v=1610352697"},{"product_id":"lt505-s","title":"LT 505-S, C\/L Hall Effect Current Sensor, 500 Amp, 100mA Output, +\/-15...24VDC, X = 0.6%","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LT 505-S, C\/L Hall Effect Current Sensor, 500 Amp, 100mA Output, +\/-15...24VDC, X = 0.6%\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated current measurement up tp 1200 Amp\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eBandwidth DC to 150kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) current transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLT 505-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eø\u003c\/span\u003e40.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC to +\/- 24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1200 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-150 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan mce-data-marked=\"1\"\u003efaston 6.3 x 0.8mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533029805\/LEM\/Datasheets\/LT_505-S_Data_Sheet_2007.08.pdf\" title=\"LEM LT 505-S\" style=\"color: #0000ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":10288338403443,"sku":"FE-LT505-S","price":605.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-lt-505-s-c-l-hall-effect-current-sensor-500-amp-100ma-output-15-24vdc-x-0-6-3370061037683.jpg?v=1610352736"},{"product_id":"lt1005-s","title":"LT 1005-S, C\/L Current Transducer,Ipn = 1000A, +\/-15\/24VDC, 200mA output, X = 0.4%","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LT 1005-S Open Loop AC\/DC Hall Effect Sensor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated current measurement up tp 2000 Amp\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eBandwidth DC to 150kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) current transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLT 1005-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eø\u003c\/span\u003e40.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC to +\/- 24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 2000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-150 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM4 theaded studs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533029654\/LEM\/Datasheets\/LT_1005-S_Data_Sheet_2010.02.pdf\" target=\"_blank\" title=\"LEM LT 1005-S Series\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\" title=\"LEM Application Manual\" rel=\"noopener noreferrer\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":10288354132083,"sku":"FE-LT1005-S","price":626.8,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-lt-1005-s-c-l-current-transducer-ipn-1000a-15-24vdc-200ma-output-x-0-4-3370089185395.jpg?v=1610352958"},{"product_id":"lt2005-s","title":"LT 2005-S, C\/L Current Transducer, Ipn = 2000A, +\/-15\/24VDC, 400mA Output, X = 0.3%","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LT 2005-S, C\/L Current Transducer, Ipn = 2000A, +\/-15\/24VDC, 400mA Output, X = 0.3%\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated current measurement up tp 3000 Amp\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eBandwidth DC to 100kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) current transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLT 2005-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eø6\u003c\/span\u003e0.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC to +\/- 24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 3000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM5 theaded studs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.55kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533029699\/LEM\/Datasheets\/LT_2005-S_Data_Sheet_2007.08.pdf\" title=\"LEM LT 2005-S Series\" style=\"color: #0000ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":10288359473267,"sku":"FE-LT2005-S","price":1029.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-lt-2005-s-c-l-current-transducer-ipn-2000a-15-24vdc-200ma-output-x-0-3-3370089087091.jpg?v=1610353074"},{"product_id":"lt4000-s","title":"LT 4000-S, C\/L Hall Effect current transducer, Ipn = 4000 Amp, Isn = 800mA, +\/-15VDC Supply","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LT 4000-S, C\/L Hall Effect current transducer, Ipn = 4000 Amp, Isn = 800mA, +\/-15VDC Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated current measurement up tp 6000 Amp\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eBandwidth DC to 100kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) current transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLT 4000-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e102mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC to +\/- 24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 6000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM5 threaded studs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.1kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533029767\/LEM\/Datasheets\/LT_4000-S_Data_Sheet_2007.07.pdf\" title=\"LEM LT4000-S Datasheet\" style=\"color: #0000ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":10288360292467,"sku":"FE-LT4000-S","price":2853.2,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-lt-4000-s-c-l-hall-effect-current-transducer-ipn-4000-amp-isn-800ma-15vdc-supply-3370092494963.jpg?v=1610353105"},{"product_id":"lt1005-s-sp4","title":"LT 1005-S\/SP4, C\/L Current Transducer, Ipn = 1000A, +\/-15\/24VDC, 250mA Output, X = 0.4%","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LT 1005-S\/SP4 Open Loop AC\/DC Hall Effect Sensor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated current measurement up tp 2000 Amp\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eBandwidth DC to 100kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) current transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLT 1005-S\/SP4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eø40.5mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC to +\/- 24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 2000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-150 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM4 theaded studs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1546580242\/LEM\/Datasheets\/lt_1005-s_sp4.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\" title=\"LEM Application Manual\" rel=\"noopener noreferrer\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18000294543475,"sku":"FE-LT1005-S\/SP4","price":983.1,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-lt-1005-s-sp4-c-l-current-transducer-ipn-1000a-15-24vdc-250ma-output-x-0-4-12027936702579.jpg?v=1610357820"},{"product_id":"itc-4000-s","title":"ITC 4000-S High Precision Hall Effect Current Sensor, 4000 Amp, 2400mA Output, 102mm Aperture, +\/-24V Supply","description":"\u003ch1\u003e\u003cspan style=\"color: #6ea4d7;\"\u003e\u003cstrong\u003eITC 4000-S High Precision Hall Effect Current Sensor, 4000 Amp, 2400mA Output, 102mm Aperture, +\/-24V Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1546579355\/LEM\/Datasheets\/itz_16000-sb_flex_ultrastab.pdf\" target=\"_blank\"\u003eProduct Datasheet \u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422757654643,"sku":"FE-ITC 4000-S","price":12747.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-high-precision-ac-dc-current-hall-effect-sensor-itc-4000-s-high-precision-hall-effect-current-sensor-4000-amp-2400ma-output-102mm-aperture-24v-supply-647901642763.jpg?v=1610359604"},{"product_id":"itl-4000-s","title":"ITL 4000-S High Precision Hall Effect Current Sensor, 4000 Amp, 1600mA Output, 268mm Aperture, +\/-24V Supply","description":"\u003ch1\u003e\u003cspan style=\"color: #6ea4d7;\"\u003e\u003cstrong\u003eITL 4000-S High Precision Hall Effect Current Sensor, 4000 Amp, 1600mA Output, 268mm Aperture, +\/-24V Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1546579355\/LEM\/Datasheets\/itz_16000-sb_flex_ultrastab.pdf\" target=\"_blank\"\u003eProduct Datasheet \u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422757720179,"sku":"FE-ITL 4000-S","price":21692.4,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-high-precision-ac-dc-current-hall-effect-sensor-itl-4000-s-high-precision-hall-effect-current-sensor-4000-amp-1600ma-output-268mm-aperture-24v-supply-647901646040.jpg?v=1610359608"},{"product_id":"itn-12-p-ultrastab","title":"ITN 12-P ULTRASTAB High Precision Hall Effect Current Sensor, 12.5 Amp, 35mA Output, No Aperture, +\/-15V Supply","description":"\u003ch1\u003e\u003cspan style=\"color: #6ea4d7;\"\u003e\u003cstrong\u003eITN 12-P ULTRASTAB High Precision Hall Effect Current Sensor, 12.5 Amp, 35mA Output, No Aperture, +\/-15V Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1546579355\/LEM\/Datasheets\/itz_16000-sb_flex_ultrastab.pdf\" target=\"_blank\"\u003eProduct Datasheet \u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422757752947,"sku":"FE-ITN 12-P ULTRASTAB","price":1474.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-high-precision-ac-dc-current-hall-effect-sensor-itn-12-p-ultrastab-high-precision-hall-effect-current-sensor-12-5-amp-35ma-output-no-aperture-15v-supply-647901655.jpg?v=1610359611"},{"product_id":"la-255-s","title":"LA 255-S C\/L Hall Effect Current Sensor, 250 Amp, 125mA Output, 23 x 18mm Aperture, +\/-12..18V Supply, Panel Mount, X = 0.8%","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LA 255-S Closed Loop AC\/DC Hall Effect Sensor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 100kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eClosed\u003c\/span\u003e loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003ePanel Mount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLA255-S\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.5 x 25.5mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-12..15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-500 Amp \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3.25 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolex series 5046 4 pins\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1564905830\/LEM\/Datasheets\/LA_255-S.pdf\" target=\"_blank\" title=\"LEM LA 255-S Series\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\" title=\"LEM Application Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422760964211,"sku":"FE-LA 255-S","price":117.8,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-la-255-s-c-l-hall-effect-current-sensor-250-amp-125ma-output-23-x-18mm-aperture-12-18v-supply-panel-mount-x-0-8-12080267624563.jpg?v=1610359673"},{"product_id":"lac-300-s","title":"LAC 300-S C\/L Hall Effect Current Sensor, 300 Amp, 100mA Output, 30 x 13mm Aperture, +\/-15V Supply, Panel Mount, X = 0.9%","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LAC 300-S Series Closed Loop AC\/DC Hall Effect Sensor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 50kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eClosed\u003c\/span\u003e loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePCB Mounted with Strain Relief\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLAC300-S\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13 x 11mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-700 Amp \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-50 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePCB Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolex series 70543-0003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e137g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1564902359\/LEM\/Datasheets\/lac_300-s_sp1.pdf\" title=\"LEM LAC Series\" style=\"color: #0000ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422761291891,"sku":"FE-LAC 300-S","price":117.8,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-lac-300-s-c-l-hall-effect-current-sensor-300-amp-100ma-output-30-x-13mm-aperture-15v-supply-panel-mount-x-0-9-12080149102707.jpg?v=1610359701"},{"product_id":"lt-1005-t","title":"LT 1005-T C\/L Hall Effect Current Sensor, Ipn = 1000 Amp, Isn = 200mA, +\/-24VDC Supply, Busbar, X = 0.4%, panel mount","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LT 1005-T Open Loop AC\/DC Hall Effect Sensor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated current measurement up tp 2000 Amp\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eBandwidth DC to 150kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) current transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLT 1005-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC to +\/- 24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 2000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-150 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbar Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM4 theaded studs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.27kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1563954505\/LEM\/Datasheets\/LT_1005-T_Data_Sheet_2007.08.pdf\" target=\"_blank\" title=\"LEM LF 1005-T Datasheet\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\" title=\"LEM Application Manual\" rel=\"noopener noreferrer\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422762668147,"sku":"FE-LT 1005-T","price":859.1,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-lt-1005-t-c-l-hall-effect-current-sensor-ipn-1000-amp-isn-200ma-24vdc-supply-busbar-x-0-4-panel-mount-12027901968499.jpg?v=1610359788"},{"product_id":"lt-2005-t","title":"LT 2005-T C\/L Hall Effect Current Sensor, Ipn = 2000 Amp, Isn = 400mA, +\/-24VDC Supply, X = 0.3%, Busbar mount","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LT 2005-T C\/L Hall Effect Current Sensor, Ipn = 2000 Amp, Isn = 400mA, +\/-24VDC Supply, X = 0.3%, Busbar mount\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated current measurement up tp 3000 Amp\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eBandwidth DC to 100kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) current transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLT 2005-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC to +\/- 24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 3000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbar Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM5 theaded studs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.4kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1563955889\/LEM\/Datasheets\/lt_2005-t_e.pdf\" title=\"LEM LT 2005-T Datasheet\" style=\"color: #0000ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422762700915,"sku":"FE-LT 2005-T","price":1608.9,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-lt-2005-t-c-l-hall-effect-current-sensor-ipn-2000-amp-isn-400ma-24vdc-supply-x-0-3-busbar-mount-6479023571059.jpg?v=1610359791"},{"product_id":"lt-4000-t","title":"LT 4000-T C\/L Hall Effect Current Sensor, Ipn = 4000 Amp, Isn = 800mA, +\/-24VDC Supply, 10mm Bubsar Mount, X = 0.5%","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LT 4000-T C\/L Hall Effect Current Sensor, Ipn = 4000 Amp, Isn = 800mA, +\/-24VDC Supply, 10mm Bubsar Mount, X = 0.5%\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated current measurement up tp 6000 Amp\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eBandwidth DC to 100kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) current transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLT 4000-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC to +\/- 24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 6000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbar Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM5 threaded studs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.1kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1563955141\/LEM\/Datasheets\/lt_4000-t_e.pdf\" title=\"LEM LT4000-T Datasheet\" style=\"color: #0000ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422762733683,"sku":"FE-LT 4000-T","price":3728.6,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-lt-4000-t-c-l-hall-effect-current-sensor-ipn-4000-amp-isn-800ma-24vdc-supply-busbar-x-0-5-panel-mount-12027943092339.jpg?v=1610359795"},{"product_id":"lt-505-t","title":"LT 505-T C\/L Hall Effect Current Sensor, 500 Amp, 100mA Output, w\/ busbar, +\/-15..24VDC, X = 0.6%","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LT 505-T Open Loop AC\/DC Hall Effect Sensor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated current measurement up tp 1200 Amp\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eBandwidth DC to 150kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) current transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLT 505-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC to +\/- 24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1200 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-150 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbar Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan mce-data-marked=\"1\"\u003eFaston 6.3 x 0.8mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1563956752\/LEM\/Datasheets\/LT_505-T_Data_Sheet_2009.10.pdf\" target=\"_blank\" title=\"LEM LT 505-T Datasheet\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\" title=\"LEM Application Manual\" rel=\"noopener noreferrer\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422762766451,"sku":"FE-LT 505-T","price":654.2,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-lt-505-t-c-l-hall-effect-current-sensor-500-amp-100ma-output-w-busbar-15-24vdc-x-0-6-6479023669363.jpg?v=1610359799"},{"product_id":"la-205-s-sp6","title":"LA 205-S\/SP6, C\/L Hall Effect Current Sensor, 200 Amp, 100mA Output, 23 x 18mm Aperture, +\/-12..18V Supply, Panel Mount, X = 0.8%","description":"\u003cp\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LA 205-S\/SP6, C\/L Hall Effect Current Sensor, 200 Amp, 100mA Output, 23 x 18mm Aperture, +\/-12..18V Supply, Panel Mount, X = 0.8%\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 100kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003ePanel Mount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLA205-S\/SP6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e23 x 18mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-12..15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-300 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFaston 6.3 x 0.8mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1564906564\/LEM\/Datasheets\/LA_205-S-SP6.pdf\" title=\"LEM LA Series\" style=\"color: #0000ff;\" target=\"_blank\"\u003e\u003cspan\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18483488030835,"sku":"FE-LA 205-S\/SP6","price":279.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-la-205-s-sp6-c-l-hall-effect-current-sensor-200-amp-100ma-output-23-x-18mm-aperture-12-18v-supply-panel-mount-x-0-8-6556410347635.jpg?v=1610361102"},{"product_id":"lt-1000-si-sp59","title":"LT 1000-SI\/SP59 C\/L Hall Effect Current Sensor, 1000 Amp, Isolation 6kV, Ratio 5000:1, +\/-15VDC Supply","description":"\u003ch1\u003e\u003cspan style=\"color: #8ac7db;\"\u003e\u003cstrong\u003eLT 1000-SI\/SP59 AC\/DC Hall Effect Current Sensor, 1000 Amp, Isolation 6kV, Ratio 5000:1, +\/-15VDC Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":29549697138803,"sku":"FE-LT 1000-SI\/SP59","price":2606.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-lt-1000-si-sp59-c-l-hall-effect-current-sensor-1000-amp-isolation-6kv-ratio-5000-1-15vdc-supply-12222439391347.jpg?v=1610362322"},{"product_id":"ltc-1000-sf-sp14","title":"LTC 1000-SF\/SP14 C\/L Hall Effect Current Sensor, 1000 Amp, 250mA Output, +\/-15..24V, Panel Mount, w\/ feet to match LT 1000-S\/SP71, X = 0.4%","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LTC 1000-SF\/SP14 Series Open Loop AC\/DC Hall Effect Sensor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDrop in replacement for LT 1000-SI\/SP71\u003cstrong\u003e with 4 pin connection (Ground)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eBipolar and insulated current measurement up tp 3000 Amp\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eBandwidth DC to 100kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) current transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway Equipment\u003c\/li\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLTC 1000-SF\/SP14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eø\u003c\/span\u003e42mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC to +\/- 24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 3000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e13.4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount (with Feet to match LT 1000-S\/SP71)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFaston 6.3 x 0.8mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e900g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1580860951\/LEM\/Datasheets\/ltc_1000-sf_sp14.pdf\" title=\"LEM LTC 1000-S\/SP14 Datasheet\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":31399132004486,"sku":"FE-LTC 1000-SF\/SP14","price":749.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/ltc_1000_sf_grande_66bcba04-3f3e-44f7-875d-34db8e6b2dc6.jpg?v=1624859891"},{"product_id":"lt-4000-t-sp24","title":"LT 4000-S\/SP24 C\/L Hall Effect Current Sensor, Ipn = 3300 Amp, Isn = 660mA, +\/-24VDC Supply, Busbar, X = 0.5%, panel mount","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LT 4000-S\/SP24 C\/L Hall Effect Current Sensor, Ipn = 3300 Amp, Isn = 660mA, +\/-24VDC Supply, Busbar, X = 0.5%, panel mount\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated current measurement up tp 6000 Amp\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eBandwidth DC to 100kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) current transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLT 4000-S\/SP24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC to +\/- 24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 6000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e660 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbar Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM5 threaded studs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.1kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1592884822\/LEM\/Datasheets\/LT_4000-S_SP24_Data_Sheet_2005.07.pdf\" title=\"LEM LT4000-T\/SP24 Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":31792376447110,"sku":"FE-LT 4000-S\/SP24","price":4976.1,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-lt-4000-s-c-l-hall-effect-current-transducer-ipn-4000-amp-isn-800ma-15vdc-supply-3370092494963_d3ee4759-e2df-4999-be67-1ddf79f0146d.jpg?v=1624862048"},{"product_id":"lt-4000-t-sp11","title":"LT 4000-T\/SP11, C\/L Hall Effect Current Sensor, +\/-24VDC Supply, Isn = 800mA, 100mm Busbar Mount, X = 0.5%, Secondary Connection by LEMOEGJ.1B.305.CYC","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LT 4000-T\/SP11, C\/L Hall Effect Current Sensor, +\/-24VDC Supply, Isn = 800mA, 100mm Busbar Mount, X = 0.5%, Secondary Connection by LEMOEGJ.1B.305.CYC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated current measurement up tp 6000 Amp\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eBandwidth DC to 100kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) current transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLT 4000-T\/SP11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC to +\/- 24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 6000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbar Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLEMOEGJ.1B.305.CYC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.1kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"LEM LT4000-T\/SP11 Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1615763010\/LEM\/Datasheets\/LT_4000_T_SP11.pdf\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":39267955835014,"sku":"FE-LT 4000-T\/SP11","price":7365.8,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-lt-4000-t-c-l-hall-effect-current-sensor-ipn-4000-amp-isn-800ma-24vdc-supply-busbar-x-0-5-panel-mount-12027943092339_f32685f9-fbf8-4a73-a46a-e3d936f10260.jpg?v=1624866064"},{"product_id":"lt-4000-t-sp35","title":"LT 4000-T\/SP35, C\/L Hall Effect Current Sensor, +\/-24VDC Supply, Isn = 800mA, 100m Busbar Mount, X = 0.5%, Secondary Connection by AMP CPC 13\/9","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LT 4000-T\/SP35, C\/L Hall Effect Current Sensor, +\/-24VDC Supply, Isn = 800mA, 100m Busbar Mount, X = 0.5%, Secondary Connection by AMP CPC 13\/9\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated current measurement up tp 6000 Amp\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eBandwidth DC to 100kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) current transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLT 4000-T\/SP35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC to +\/- 24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 6000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbar Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAMP CPC 13\/9\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.1kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1615763010\/LEM\/Datasheets\/LT_4000_T_SP35.pdf\" title=\"LEM LT4000-T\/SP35 Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca title=\"LEM Application Manual\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":39267957506182,"sku":"FE-LT 4000-T\/SP11","price":7365.8,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-lt-4000-t-c-l-hall-effect-current-sensor-ipn-4000-amp-isn-800ma-24vdc-supply-busbar-x-0-5-panel-mount-12027943092339_112d27b4-c011-438e-96d2-6225a2f77bd7.jpg?v=1624866067"},{"product_id":"lac-300-s-sp1","title":"LAC 300-S\/SP1, C\/L Hall Effect Current Sensor, 300 Amp, 150mA Output, 30 x 13mm Aperture, +\/-15V Supply, Panel Mount, X = 0.9%","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LAC 300-S\/SP1, C\/L Hall Effect Current Sensor, 300 Amp, 150mA Output, 30 x 13mm Aperture, +\/-15V Supply, Panel Mount, X = 0.9%\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 50kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eClosed\u003c\/span\u003e loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePCB Mounted with Strain Relief\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLAC 300-S\/SP1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13 x 11mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-700 Amp \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-50 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePCB Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolex series 70543-0003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e137g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1644563034\/LEM\/Datasheets\/LAC_300-S_SP1_Data_Sheet_2007.07.pdf\" title=\"LEM LAC 300-S\/SP1 Series\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":39688369209478,"sku":"FE-LAC 300-S\/SP1","price":158.7,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-lac-300-s-c-l-hall-effect-current-sensor-300-amp-100ma-output-30-x-13mm-aperture-15v-supply-panel-mount-x-0-9-12080149102707_aeb01327-1095-45ab-80e7-fe3f977889f2.jpg?v=1644562948"},{"product_id":"lt-505-t-sp22","title":"LT 505-T\/SP22, C\/L Hall Effect Current Sensor, 500 Amp, 100mA Output, w\/ busbar, +\/-15..24VDC, X = 0.6%, SP22 = -40 to 85 Deg, M4 stud Secondary Connections","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LT 505-T C\/L Hall Effect Current Sensor, 500 Amp, 100mA Output, w\/ busbar, +\/-15..24VDC, X = 0.6%, Can replace \u003cspan lang=\"EN-US\" data-mce-fragment=\"1\"\u003eLT 505-T\/SP3\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and Insuated current measurement up tp 1200 Amp\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eBandwidth DC to 150kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) current transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offest drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLT 505-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC to +\/- 24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1200 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-150 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbar Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan mce-data-marked=\"1\"\u003eFaston 6.3 x 0.8mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff;\" title=\"LEM LT 505-T Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1563956752\/LEM\/Datasheets\/LT_505-T_Data_Sheet_2009.10.pdf\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca title=\"LEM Application Manual\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":39838945869958,"sku":null,"price":654.2,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-lt-505-t-c-l-hall-effect-current-sensor-500-amp-100ma-output-w-busbar-15-24vdc-x-0-6-6479023669363_05381ff6-073d-450f-a4f1-6039d48cc7ae.jpg?v=1659481608"},{"product_id":"lt-4000-t-sp42","title":"LT 4000-T\/SP42, C\/L Hall Effect Current Sensor, Ipn = 4400 Amp (+\/-12000 Amp Measurement Range), Isn = 880mA, +\/-60VDC Supply, 60mm Busbar, X = 0.2%, Busbar\/Panel Mount","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LT 4000-T\/SP42, C\/L Hall Effect Current Sensor, Ipn = 4400 Amp (+\/-12000 Amp Measurement Range), Isn = 880mA, +\/-60VDC Supply, 60mm Busbar, X = 0.2%, Busbar\/Panel Mount\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated current measurement up tp 6000 Amp\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eBandwidth DC to 100kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) current transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLT 4000-T\/SP42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 60 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4400 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 12000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e880 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbar Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM5 threaded studs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.1kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1693302028\/LEM\/Datasheets\/LT_4000-T_SP42.pdf\" title=\"LEM LT4000-T\/SP42 Datasheet\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":40223697633414,"sku":"FE-LT 4000-T\/SP42","price":5528.6,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/lem-international-sa-ac-dc-current-hall-effect-sensor-lt-4000-t-c-l-hall-effect-current-sensor-ipn-4000-amp-isn-800ma-24vdc-supply-busbar-x-0-5-panel-mount-12027943092339_9ec7c9ba-86c7-4b9a-bc95-64b50a007837.jpg?v=1693297050"},{"product_id":"lt-1005-s-sp29","title":"LT 1005-S\/SP29, C\/L Current Transducer,Ipn = 1000A, +\/-15\/24VDC, 200mA output, X = 0.4%","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LT 1005-S\/SP29, C\/L Current Transducer,Ipn = 1000A, +\/-15\/24VDC, 200mA output, X = 0.4%\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated current measurement up tp 2000 Amp\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eBandwidth DC to 150kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) current transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSP19 = Ip = +\/-2400A, Vc = +\/-15..24V, Vd = 12kV, Ta = -40 Deg C(-50 Deg C)..+85 Deg C\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLT 1005-S\/SP29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eø\u003c\/span\u003e40.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC to +\/- 24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 2400 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-150 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM4 theaded studs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1697692632\/LEM\/Datasheets\/LT_1005-S_SP19_Data_Sheet_2006.04.pdf\" title=\"LEM LT 1005-S\/SP29 Series\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":40279754276998,"sku":"FE-LT 1005-S\/SP29","price":1130.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/lem-international-sa-ac-dc-current-hall-effect-sensor-lt-1005-s-c-l-current-transducer-ipn-1000a-15-24vdc-200ma-output-x-0-4-3370089185395_c8743bf4-ff94-443d-828a-f9b1db5424a4.jpg?v=1697692677"},{"product_id":"lt-10000-s","title":"LT 10000-S, C\/L Hall Effect current transducer, Ipn = 10000 Amp, Isn = 1000mA, +\/-48..60VDC Supply","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LT 10000-S, C\/L Hall Effect current transducer, Ipn = 10000 Amp, Isn = 1000mA, +\/-48..60VDC Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated current measurement up tp 6000 Amp\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eBandwidth DC to 100kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) current transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eCurrent overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLT 10000-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 48 VDC to +\/- 60 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eLoad Current (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15000 Amp (with +\/-60VDC Supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM5 threaded studs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1699582390\/LEM\/Datasheets\/LT_10000-S_Data_Sheet_2003.10.pdf\" title=\"LEM LT 10000-S Datasheet\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003ca title=\"LEM Application Manual\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":40358519111814,"sku":"FE-LT 10000-S","price":12689.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/lem-international-sa-ac-dc-current-hall-effect-sensor-lt-4000-s-c-l-hall-effect-current-transducer-ipn-4000-amp-isn-800ma-15vdc-supply-3370092494963_dfaf47bb-ad7b-4e6f-80b1-9bf1ec4ad815.jpg?v=1699582129"},{"product_id":"93-32-13-004-0","title":"93.32.13.004.0, Busbar Mounting KIT for LT 505-S and LT 1005-S  for 12 x 40mm busbar","description":"\u003ch3\u003e\u003cspan style=\"color: #8cb9de;\"\u003e\u003cstrong\u003e93.32.13.004.0, Busbar Mounting KIT for LT 505-S and LT 1005-S  for 12 x 40mm busbar\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1540107269\/LEM\/Datasheets\/ltc_600-s.pdf\" title=\"LEM LTC 600\/1000 Busbar Kit Datasheet\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":42499077406854,"sku":null,"price":47.0,"currency_code":"AUD","in_stock":false}]}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/collections\/LEM_New_Logo_ebdd779a-7996-4f6b-8d3c-1b6904668ec3.png?v=1651018739","url":"https:\/\/fastron.com.au\/collections\/lem-price-group-14.oembed?page=3","provider":"Fastron Electronics Store ","version":"1.0","type":"link"}