{"title":"LEM Hall Effect Voltage Sensors Panel Mount","description":"\u003ch1\u003e\u003cspan style=\"color: #96c6e1;\"\u003eLEM Hall Effect Voltage Transducers\u003c\/span\u003e\u003c\/h1\u003e\n\u003cbr\u003e\n\u003cp\u003eLooking for LEM Voltage Transducers?  Fastron has the largest range of LEM Voltage sensors in Australia. From Railway approved sensors to laboratory voltage measurements, we have you covered. Our warehouse is located in Melbourne Australia for quick delivery worldwide. Some specials(SP) from LEM are not currently listed. \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"\/pages\/lem-hall-effect-sensor-current-parts-list\" target=\"_blank\" title=\"LEM current parts list\" style=\"color: #2b00ff;\" rel=\"noopener noreferrer\"\u003eSee here\u003c\/a\u003e\u003c\/span\u003e. Feel free to \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"\/pages\/contact-us\" target=\"_blank\" title=\"Contact Fastron\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003econtact us\u003c\/a\u003e\u003c\/span\u003e for any products not shown here and we can generally respond in 12 hours. \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\" title=\"LEM Hall Effect Sensor Application Notes\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003eDownload Application Notes\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"lv25-400","title":"LV 25-400, C\/L Voltage Transducer, 400V, 25mA Output","description":"\u003ch1\u003e\u003cspan style=\"color: #76aadb;\"\u003e\u003cstrong\u003eLEM LV Series Closed Loop AC\/DC Hall Effect Voltage Sensor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 40kHz\u003c\/li\u003e\n\u003cli\u003eMulti Range through pin selection\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel Mount\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eLV 25-400\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-12..15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e400V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e0 - 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e25 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4.1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-40 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePCB Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e0.8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eFastron 6.3 x 0.8mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e60g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533030442\/LEM\/Datasheets\/LV_25-400_Data_Sheet_2006.09.pdf\" target=\"_blank\" title=\"LEM LV 25-400 Series\" rel=\"noopener noreferrer\"\u003e\u003cspan\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\" title=\"LEM Application Manual\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":10288343646323,"sku":"FE-LV25-400","price":304.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-lv-25-400-c-l-voltage-transducer-400v-25ma-output-3370065526899.jpg?v=1610352769"},{"product_id":"dvl1000","title":"DVL 1000, Digital Voltage Transducer 1000V Input, 50mA output, +\/- 15V…24VDC, 8.5kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #7baede;\"\u003e\u003cstrong\u003eLEM DVL Series Closed Loop AC\/DC Digital Voltage Transducer 1000V Input, 50mA output, +\/- 15V…24VDC, 8.5kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 14kHz\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVL 1000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\n\u003cspan\u003e+\/- \u003c\/span\u003e1500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e50 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e8.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-14 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1532671398\/LEM\/Datasheets\/DVL_1000.pdf\" title=\"LEM DVL 1000 Series\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":10288346103923,"sku":"FE-DVL1000","price":551.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvl-1000-voltage-transducer-1000v-input-50ma-output-15v-24vdc-8-5kv-isolation-3370067099763.jpg?v=1610352790"},{"product_id":"lv100-2000-sp6","title":"LV 100-2000\/SP6, C\/L Hall Effect Voltage Transducer, 2000V, 50mA Output","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LV 100-2000\/SP6 C\/L Voltage Transducer, 2000V, +\/-15VDC Aux, 50mA Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated voltage measurement up tp 3000VAC\/DC\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) voltage \u003cspan style=\"color: #6fa8dc;\"\u003etransducer\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway Equipment\u003c\/li\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003eTraction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLV 100-2000\/SP6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePrimary RMS Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000V\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 3000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResponse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200uS\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFaston 45° \u003c\/span\u003e\u003cspan\u003e6.3 x 0.8mm\u003c\/span\u003e\u003cspan\u003e and M5 threaded studs\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e870g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552034963\/LEM\/New%20LEM%20Datasheets\/LV_100-2000_SP6_Data_Sheet_2009.07.pdf\" title=\"LEM LV100-2000\/SP6 Series\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":10288348627059,"sku":"FE-LV100-2000\/SP6","price":1250.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-lv-100-2000-sp6-c-l-hall-effect-voltage-transducer-2000v-50ma-output-3370070835315.jpg?v=1610352811"},{"product_id":"lv100-1500-sp3","title":"LV 100-1500\/SP3, C\/L Hall Effect Voltage Transducer, 1500V, 50mA Output","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LV 100-1500\/SP3 C\/L Voltage Transducer, 1500V, +\/-15VDC Aux, 50mA Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated voltage measurement up tp 2250VAC\/DC\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) voltage transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway Equipment\u003c\/li\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003eTraction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLV 100-1500\/SP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePrimary RMS Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500V\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 2250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResponse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200uS\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFaston 45° \u003c\/span\u003e\u003cspan\u003e6.3 x 0.8mm\u003c\/span\u003e\u003cspan\u003e and M5 threaded studs\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e870g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552034960\/LEM\/New%20LEM%20Datasheets\/LV_100-1500_SP3_Data_Sheet_2003.02.pdf\" title=\"LEM LV100-1500\/SP3 Series\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":10288352559219,"sku":"FE-LV100-1500\/SP3","price":975.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-lv-100-1500-sp3-c-l-hall-effect-voltage-transducer-2000v-50ma-output-3370075848819.jpg?v=1610352928"},{"product_id":"dvl2000","title":"DVL 2000, Digital Voltage Transducer 2000V, +\/-15...24VDC Supply, 50mA Output, 8.5kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #95b9df;\"\u003e\u003cstrong\u003eLEM \u003c\/strong\u003e\u003cstrong\u003eDVL 2000 Series Closed Loop AC\/DC Digital Voltage Transducer 2000V Input, 50mA output, +\/- 15V…24VDC, 8.5kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 14kHz\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel Mount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVL 2000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 2000V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\n\u003cspan\u003e+\/- \u003c\/span\u003e3000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e50 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e8.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-14 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1532671396\/LEM\/Datasheets\/dvl_2000.pdf\" title=\"LEM DVL 2000 Series\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":10288353575027,"sku":"FE-DVL2000","price":565.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvl-2000-voltage-transducer-2000v-15-24vdc-supply-50ma-output-8-5kv-isolation-3370078535795.jpg?v=1610352954"},{"product_id":"lv100-1500","title":"LV 100-1500, C\/L Voltage Transducer, 1500V, +\/-15VDC Aux, 50mA Output","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LV 100-1500 C\/L Voltage Transducer, 1500V, +\/-15VDC Aux, 50mA Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated voltage measurement up tp 2250VAC\/DC\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) voltage transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway Equipment\u003c\/li\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003eTraction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLV 100-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePrimary RMS Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500V\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 2250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120uS\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFaston 45° \u003c\/span\u003e\u003cspan\u003e6.3 x 0.8mm\u003c\/span\u003e\u003cspan\u003e and M5 threaded studs\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533030159\/LEM\/Datasheets\/LV_100-1500_Data_Sheet_2003.01.pdf\" title=\"LEM LV100-1500 Series\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":10288354689139,"sku":"FE-LV100-1500","price":879.3,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-lv-100-1500-c-l-voltage-transducer-1500v-15vdc-aux-50ma-output-3370079387763.jpg?v=1610352961"},{"product_id":"dvl-1500","title":"DVL 1500, Digital Voltage Transducer, 1500V, +\/-15...24VDC, 50mA output, 8.5kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #7baede;\"\u003e\u003cstrong\u003eLEM DVL 1500, Digital Voltage Transducer, 1500V, +\/-15...24VDC, 50mA output, 8.5kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 14kHz\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel Mount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVL 1500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 1500V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\n\u003cspan\u003e+\/- \u003c\/span\u003e2250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e50 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e8.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-14 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1532671400\/LEM\/Datasheets\/DVL_1500.pdf\" title=\"LEM DVL 1500 Series\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":10288355180659,"sku":"FE-DVL1500","price":551.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvl-1500-digital-voltage-transducer-1500v-15-24vdc-50ma-output-8-5kv-isolation-3370079518835.jpg?v=1610352966"},{"product_id":"cv3-200-sp5","title":"CV 3-200\/SP5, Voltage Transducer Flux Gate, Vpn = 140V RMS, 10V output, +\/- 15\/24VDC supply, 2.5kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #84b0df;\"\u003e\u003cstrong\u003eCV 3-200\/SP5 Voltage Transducer Flux Gate, Vpn = 140V RMS, 10V output, +\/- 15\/24VDC supply, 2.5kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 700kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Flux Gate\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eHigh Frequency Drives\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eCV 3-200\/SP5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 140V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e10V @Vp(max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e2.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-700 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-25\u003cspan\u003e°C\u003c\/span\u003e \/ 75\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e650g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1533025427\/LEM\/Datasheets\/CV_3-200_SP5_Data_Sheet_2007.04.pdf\" title=\"LEM CV3-200\/SP5 Series\" style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff;\" title=\"LEM Application Manual\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":10288359932019,"sku":"FE-CV3-200\/SP5","price":1698.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-cv3-200-sp5-voltage-transducer-vpn-140v-rms-10v-output-15-24vdc-supply-4487077462131.jpg?v=1610353085"},{"product_id":"lv100-500","title":"LV 100-500, C\/L Voltage Transducer, 500V, +\/-15VDC Aux, 50mA Output","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LV 100-500 C\/L Voltage Transducer, 500V, +\/-15VDC Aux, 50mA Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated voltage measurement up tp 750VAC\/DC\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) voltage transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway Equipment\u003c\/li\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003eTraction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLV 100-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePrimary RMS Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500V\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResponse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190uS\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFaston 45° \u003c\/span\u003e\u003cspan\u003e6.3 x 0.8mm\u003c\/span\u003e\u003cspan\u003e and M5 threaded studs\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552034958\/LEM\/New%20LEM%20Datasheets\/LV_100-500_Data_Sheet_2003.01.pdf\" title=\"LEM LV100-500 Series\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18000253419635,"sku":"FE-LV100-500","price":879.3,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-lv-100-500-c-l-voltage-transducer-500v-15vdc-aux-50ma-output-6466247360627.jpg?v=1610355959"},{"product_id":"lv-100","title":"LV100, C\/L Voltage Transducer, 10mA Primary, +\/-15VDC Aux, 50mA Output","description":"\u003ch1\u003e\u003cspan style=\"color: #93b7de;\"\u003e\u003cstrong\u003eLV100, C\/L Voltage Transducer, 10mA Primary, +\/-15VDC Aux, 50mA Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #93b7de;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eUsed for Voltage Transducer Design\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCurrent input and output\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) voltage transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway Equipment\u003c\/li\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003eTraction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLV 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePrimary Nominal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 20 mAmp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 - 100uS\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e0°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFaston 45° \u003c\/span\u003e\u003cspan\u003e6.3 x 0.8mm\u003c\/span\u003e\u003cspan\u003e and M5 threaded studs\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e460g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552208427\/LEM\/New%20LEM%20Datasheets\/LV100.pdf\" title=\"LV100 Datasheet\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422764961907,"sku":"FE-LV 100","price":549.6,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-lv100-c-l-voltage-transducer-10ma-primary-15vdc-aux-50ma-output-6479024455795.jpg?v=1610359853"},{"product_id":"cv-3-1000","title":"CV 3-1000 Digital Voltage Transducer Flux Gate, Vpn = 700V, +\/-15VDC, 10V output, 6kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #8bacda;\"\u003e\u003cstrong\u003eLEM CV 3-1000 Digital Voltage Transducer Flux Gate, Vpn = 700V, +\/-15VDC, 10V output, 6kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 500kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Flux Gate\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eHigh Frequency Drives\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eCV 3-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 700V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e10V @Vp(max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-500 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-25\u003cspan\u003e°C\u003c\/span\u003e \/ 75\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e650g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552035068\/LEM\/New%20LEM%20Datasheets\/CV_3-1000_Data_Sheet_2009.04.pdf\" title=\"LEM CV3-1000 Datasheet\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422765322355,"sku":"FE-CV 3-1000","price":1515.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-cv-3-1000-digital-voltage-transducer-vpn-2828v-15vdc-10v-output-9kv-isolation-6479025045619.jpg?v=1610359869"},{"product_id":"cv-3-1200","title":"CV 3-1200 Digital Voltage Transducer Flux Gate, Vpn = 2828V, +\/-15VDC, 10V output, 6kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #8db3df;\"\u003e\u003cstrong\u003eLEM CV 3-1200 Digital Voltage Transducer Flux Gate, Vpn = 2828V, +\/-15VDC, 10V output, 9kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 800kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Flux Gate\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eHigh Frequency Drives\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eCV 3-1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 840V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 1200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e10V @Vp(max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-800 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-25\u003cspan\u003e°C\u003c\/span\u003e \/ 75\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e650g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"CV 3-1200 LEM Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552035068\/LEM\/New%20LEM%20Datasheets\/CV_3-1500_Data_Sheet_2006.08.pdf\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422765355123,"sku":"FE-CV 3-1200","price":1515.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-cv-3-1200-digital-voltage-transducer-vpn-2828v-15vdc-10v-output-9kv-isolation-6479025078387.jpg?v=1610359872"},{"product_id":"cv-3-1500","title":"CV 3-1500 Digital Voltage Transducer, Flux Gate, Vpn = 1000V, +\/-15VDC, 10V output, 6kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #8db3df;\"\u003e\u003cstrong\u003eLEM CV 3-1500 Digital Voltage Transducer Flux Gate, Vpn = 1000V, +\/-15VDC, 10V output, 6kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 800kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Flux Gate\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eHigh Frequency Drives\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eCV 3-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 1500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e10V @Vp(max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-800 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-25\u003cspan\u003e°C\u003c\/span\u003e \/ 75\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e650g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"CV 3-1500 LEM Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552035068\/LEM\/New%20LEM%20Datasheets\/CV_3-1500_Data_Sheet_2006.08.pdf\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422765387891,"sku":"FE-CV 3-1500","price":1515.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-cv-3-1500-digital-voltage-transducer-vpn-2828v-15vdc-10v-output-9kv-isolation-6479025111155.jpg?v=1610359876"},{"product_id":"cv-3-200","title":"CV 3-200 Digital Voltage Transducer Flux Gate, Vpn = 140V, +\/-15VDC, 10V output, 6kV Isolation","description":"\u003ch1\u003e\n\u003cspan style=\"color: #86afdf;\"\u003e\u003cstrong\u003eLEM CV 3-200 Digital Voltage Transducer Flux Gate, Vpn = 140V, +\/-15VDC, 10V output, 6kV Isolation\u003c\/strong\u003e\u003c\/span\u003e \u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 300kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Flux Gate\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eHigh Frequency Drives\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eCV 3-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 140V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e10V @Vp(max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-300 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-25\u003cspan\u003e°C\u003c\/span\u003e \/ 75\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e650g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"CV 3-200 LEM Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552035067\/LEM\/New%20LEM%20Datasheets\/CV_3-200_2003.06.pdf\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422765420659,"sku":"FE-CV 3-200","price":1515.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-cv-3-200-digital-voltage-transducer-vpn-2828v-15vdc-10v-output-9kv-isolation-6479025209459.jpg?v=1610359881"},{"product_id":"cv-3-2000","title":"CV 3-2000 Digital Voltage Transducer Flux Gate, Vpn = 1400V, +\/-15VDC, 10V output, 6kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #8cb2de;\"\u003e\u003cstrong\u003eLEM CV 3-2000 Digital Voltage Transducer Flux Gate, Vpn = 1400V, +\/-15VDC, 10V output, 6kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 300kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Flux Gate\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eHigh Frequency Drives\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eCV 3-2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 1400V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 2000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e10V @Vp(max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-300 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-25\u003cspan\u003e°C\u003c\/span\u003e \/ 75\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e650g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"CV 3-2000 LEM Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552035068\/LEM\/New%20LEM%20Datasheets\/CV_3-2000_Data_Sheet_2006.08.pdf\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422765486195,"sku":"FE-CV 3-2000","price":1565.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-cv-3-2000-digital-voltage-transducer-vpn-2828v-15vdc-10v-output-9kv-isolation-6479025242227.jpg?v=1610359884"},{"product_id":"cv-3-500","title":"CV 3-500 Digital Voltage Transducer Flux Gate, Vpn = 350V, +\/-15VDC, 10V output, 6kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #85b1dc;\"\u003e\u003cstrong\u003eLEM CV 3-500 Digital Voltage Transducer Flux Gate, Vpn = 350V, +\/-15VDC, 10V output, 6kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 300kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Flux Gate\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eHigh Frequency Drives\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eCV 3-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 350V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e10V @Vp(max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e2.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-300 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-25\u003cspan\u003e°C\u003c\/span\u003e \/ 75\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e650g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"CV 3-500 LEM Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552035067\/LEM\/New%20LEM%20Datasheets\/CV_3-500_Data_Sheet_2006.11.pdf\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422765518963,"sku":"FE-CV 3-500","price":1495.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-cv-3-500-digital-voltage-transducer-vpn-2828v-15vdc-10v-output-9kv-isolation-6479025537139.jpg?v=1610359888"},{"product_id":"cv-4-4000","title":"CV 4-4000 Digital Voltage Transducer, Vpn = 2828V, +\/-15VDC, 10V output, 9kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #8cb2de;\"\u003e\u003cstrong\u003eLEM CV 4-4000 Digital Voltage Transducer, Vpn = 2828V, +\/-15VDC, 10V output, 9kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 11kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Flux Gate\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eHigh Frequency Drives\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eCV 4-4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 2828V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 4000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e10V @Vp(max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e9 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-11 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-25\u003cspan\u003e°C\u003c\/span\u003e \/ 75\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e650g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552035084\/LEM\/New%20LEM%20Datasheets\/CV_4-4000_Data_Sheet_2006.11.pdf\" title=\"CV4-4000 LEM Datasheet\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422765551731,"sku":"FE-CV 4-4000","price":2295.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-cv-4-4000-digital-voltage-transducer-vpn-2828v-15vdc-10v-output-9kv-isolation-6479025569907.jpg?v=1610359892"},{"product_id":"cv-4-4000-sp1","title":"CV 4-4000\/SP1 Digital Voltage Transducer, Vpn = 2800V, +\/-24VDC, 10V output, 9kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #8cb2de;\"\u003e\u003cstrong\u003eLEM CV 4-4000\/SP1 Digital Voltage Transducer, Vpn = 2800V, +\/-24VDC, 10V output, 9kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 6kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Flux Gate\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eHigh Frequency Drives\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eCV 4-4000\/SP1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 2800V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 4000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e10V @Vp(max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e9 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-6 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-25\u003cspan\u003e°C\u003c\/span\u003e \/ 75\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e650g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552205426\/LEM\/New%20LEM%20Datasheets\/cv_4-4000_sp1.pdf\" title=\"CV4-4000\/SP1 LEM Datasheet\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422765584499,"sku":"FE-CV 4-4000\/SP1","price":2455.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-cv-4-4000-sp1-digital-voltage-transducer-vpn-2828v-24vdc-10v-output-9kv-isolation-6479025602675.jpg?v=1610359895"},{"product_id":"cv-4-6000","title":"CV 4-6000, Digital Voltage Transducer, Vpn = 4242V, +\/-15VDC, 10V output, 9kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #8cb2de;\"\u003e\u003cstrong\u003eLEM CV 4-6000 Digital Voltage Transducer, Vpn = 4242V, +\/-15VDC, 10V output, 9kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 11kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Flux Gate\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eHigh Frequency Drives\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eCV 4-6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 4242V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 6000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e10V @Vp(max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e9 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-11 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-25\u003cspan\u003e°C\u003c\/span\u003e \/ 75\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e650g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"CV4-6000 LEM Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552035084\/LEM\/New%20LEM%20Datasheets\/CV_4-6000_Data_Sheet_2006.11.pdf\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422765650035,"sku":"FE-CV 4-6000","price":2098.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-current-hall-effect-sensor-cv-4-6000-digital-voltage-transducer-vpn-4200v-15vdc-10v-output-9kv-isolation-6479025635443.jpg?v=1610359899"},{"product_id":"dvl-1000-sp1","title":"DVL 1000\/SP1 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation, SMS6GE6 Burndy connector output, DTR0000306545","description":"\u003ch1\u003e\u003cspan style=\"color: #7baede;\"\u003e\u003cstrong\u003eLEM DVL 1000\/SP1 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation, SMS6GE6 Burndy connector output, DTR0000306545\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 14kHz\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003cli\u003eSMS6GE6 Burndy connector output, DTR0000306545\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVL 1000\/SP1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\n\u003cspan\u003e+\/- \u003c\/span\u003e1500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e50 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e8.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-14 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eSMS6GE6 Burndy connector output, DTR0000306545\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552203401\/LEM\/New%20LEM%20Datasheets\/dvl_1000_sp1.pdf\" title=\"LEM DVL Series Datasheet\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422765682803,"sku":"FE-DVL 1000\/SP1","price":596.2,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvl-1000-sp1-digital-voltage-transducer-vpn-1000v-50ma-output-15-24vdc-powered-8-5kv-isolation-sms6ge6-burndy-connector-output-dt.jpg?v=1610359903"},{"product_id":"dvl-1000-sp5","title":"DVL 1000\/SP5 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation, Threaded inserts output, Short input studs","description":"\u003ch1\u003e\u003cspan style=\"color: #7baede;\"\u003e\u003cstrong\u003eLEM DVL 1000\/SP5 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation, Threaded inserts output, Short input studs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 14kHz\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003cli\u003eThreaded inserts output, Short input studs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVL 1000\/SP5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\n\u003cspan\u003e+\/- \u003c\/span\u003e1500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e50 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e8.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-14 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eThreaded inserts output, Short input studs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552203566\/LEM\/New%20LEM%20Datasheets\/dvl_1000_sp5.pdf\" title=\"LEM DVL Series Datasheet\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422765715571,"sku":"FE-DVL 1000\/SP5","price":565.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvl-1000-sp5-digital-voltage-transducer-vpn-1000v-50ma-output-15-24vdc-powered-8-5kv-isolation-threaded-inserts-output-short-inpu.jpg?v=1610359907"},{"product_id":"dvl-1000-sp7","title":"DVL 1000\/SP7 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation, Input and output cables","description":"\u003ch1\u003e\u003cspan style=\"color: #7baede;\"\u003e\u003cstrong\u003eLEM DVL 1000\/SP7 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation, Input and output cables\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 14kHz\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003cli\u003eInput and output cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVL 1000\/SP7\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\n\u003cspan\u003e+\/- \u003c\/span\u003e1500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e50 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e8.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-14 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eInput and output cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"LEM DVL Series Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552204412\/LEM\/New%20LEM%20Datasheets\/dvl_1000_sp7.pdf\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff;\" title=\"LEM Application Manual\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422765813875,"sku":"FE-DVL 1000\/SP7","price":649.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvl-1000-sp7-digital-voltage-transducer-vpn-1000v-50ma-output-15-24vdc-powered-8-5kv-isolation-input-and-output-cables-6479025733.jpg?v=1610359910"},{"product_id":"dvl-1000-sp8","title":"DVL 1000\/SP8 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation, Output cables","description":"\u003ch1\u003e\u003cspan style=\"color: #7baede;\"\u003e\u003cstrong\u003eLEM DVL 1000\/SP8 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation, Output cables\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 14kHz\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVL 1000\/SP8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\n\u003cspan\u003e+\/- \u003c\/span\u003e1500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e50 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e8.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-14 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eOutput cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552204901\/LEM\/New%20LEM%20Datasheets\/dvl_1000_sp8.pdf\" title=\"LEM DVL Series Datasheet\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766010483,"sku":"FE-DVL 1000\/SP8","price":689.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvl-1000-sp8-digital-voltage-transducer-vpn-1000v-50ma-output-15-24vdc-powered-8-5kv-isolation-output-cables-6479025832051.jpg?v=1610359914"},{"product_id":"dvl-125","title":"DVL 125 Digital Voltage Transducer, Vpn = 125V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #7baede;\"\u003e\u003cstrong\u003eLEM DVL 125 Digital Voltage Transducer, Vpn = 125V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 14kHz\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel Mount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVL 125\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 125V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\n\u003cspan\u003e+\/- \u003c\/span\u003e 187.5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e50 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e8.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-14 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"LEM DVL Series Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1532671407\/LEM\/Datasheets\/dvl_50.pdf\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff;\" title=\"LEM Application Manual\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766043251,"sku":"FE-DVL 125","price":551.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvl-125-digital-voltage-transducer-vpn-125v-50ma-output-15-24vdc-powered-8-5kv-isolation-6479025864819.jpg?v=1610359918"},{"product_id":"dvl-150","title":"DVL 150 Digital Voltage Transducer, Vpn = 150V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #7baede;\"\u003e\u003cstrong\u003eLEM DVL 150 Digital Voltage Transducer, Vpn = 150V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 14kHz\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel Mount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVL 150\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 150V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\n\u003cspan\u003e+\/- \u003c\/span\u003e225V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e50 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e8.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-14 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1532671407\/LEM\/Datasheets\/dvl_50.pdf\" title=\"LEM DVL Series Datasheet\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766076019,"sku":"FE-DVL 150","price":551.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvl-150-digital-voltage-transducer-vpn-150v-50ma-output-15-24vdc-powered-8-5kv-isolation-6479025897587.jpg?v=1610359922"},{"product_id":"dvl-1500-sp7","title":"DVL 1500\/SP7 Digital Voltage Transducer, Vpn = 1500V, 10V output, +\/-15...24VDC powered, 8.5kV Isolation, Output Connections M5 Inserts","description":"\u003ch1\u003e\u003cspan style=\"color: #7baede;\"\u003e\u003cstrong\u003eLEM DVL 1500\/SP7 Digital Voltage Transducer, Vpn = 1500V, 10V output, +\/-15...24VDC powered, 8.5kV Isolation, Output Connections M5 Inserts\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 14kHz\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel Mount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003cli\u003eOutput Connections M5 Inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVL 1500\/SP7\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 1500V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\n\u003cspan\u003e+\/- \u003c\/span\u003e2250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e50 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e8.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-14 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eOutput Connections M5 Inserts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552204142\/LEM\/New%20LEM%20Datasheets\/dvl_1500_sp7.pdf\" title=\"LEM DVL Series Datasheet\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766141555,"sku":"FE-DVL 1500\/SP7","price":669.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvl-1500-sp7-digital-voltage-transducer-vpn-1500v-10v-output-15-24vdc-powered-8-5kv-isolation-output-connections-m5-inserts-64790.jpg?v=1610359926"},{"product_id":"dvl-2000-sp1","title":"DVL 2000\/SP1 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation, SMS6GE6 Burndy connector output, DTR0000333181","description":"\u003ch1\u003e\u003cspan style=\"color: #7fb1e1;\"\u003e\u003cstrong\u003eLEM DVL 2000\/SP1 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation, SMS6GE6 Burndy connector output, DTR0000333181\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cbr\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 14kHz\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel Mount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSMS6GE6 Burndy connector output, DTR0000333181\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 528px;\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px; width: 236.795px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px; width: 290.205px;\"\u003e\u003cspan\u003eDVL 2000\/SP1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px; width: 236.795px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px; width: 290.205px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px; width: 236.795px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px; width: 290.205px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px; width: 236.795px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px; width: 290.205px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px; width: 236.795px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px; width: 290.205px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px; width: 236.795px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px; width: 290.205px;\"\u003e\u003cspan\u003e+\/- 2000V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px; width: 236.795px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px; width: 290.205px;\"\u003e\n\u003cspan\u003e+\/- \u003c\/span\u003e3000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px; width: 236.795px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px; width: 290.205px;\"\u003e50 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px; width: 236.795px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px; width: 290.205px;\"\u003e8.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px; width: 236.795px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px; width: 290.205px;\"\u003eDC-14 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px; width: 236.795px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px; width: 290.205px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px; width: 236.795px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px; width: 290.205px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px; width: 236.795px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px; width: 290.205px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px; width: 236.795px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px; width: 290.205px;\"\u003e\u003cspan\u003eSMS6GE6 Burndy connector output, DTR0000333181\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px; width: 236.795px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px; width: 290.205px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px; width: 236.795px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px; width: 290.205px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552203905\/LEM\/New%20LEM%20Datasheets\/dvl_2000_sp1.pdf\" title=\"LEM DVL Series Datasheet\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766207091,"sku":"FE-DVL 2000\/SP1","price":644.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvl-2000-sp1-digital-voltage-transducer-vpn-2000v-50ma-output-15-24vdc-powered-8-5kv-isolation-sms6ge6-burndy-connector-output-dt.jpg?v=1610359931"},{"product_id":"dvl-2000-sp5","title":"DVL 2000\/SP5 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation, Input and output cables","description":"\u003ch1\u003e\u003cspan style=\"color: #7baede;\"\u003e\u003cstrong\u003eLEM DVL 2000\/SP5 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation, Input and output cables\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 14kHz\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel Mount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003cli\u003eInput and output cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVL 2000\/SP5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 2000V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\n\u003cspan\u003e+\/- \u003c\/span\u003e3000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e50 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e8.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-14 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eInput and output cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552203816\/LEM\/New%20LEM%20Datasheets\/dvl_2000_sp5.pdf\" title=\"LEM DVL Series Datasheet\" target=\"_blank\"\u003e\u003cspan\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766239859,"sku":"FE-DVL 2000\/SP5","price":689.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvl-2000-sp5-digital-voltage-transducer-vpn-2000v-50ma-output-15-24vdc-powered-8-5kv-isolation-input-and-output-cables-6479026061.jpg?v=1610359935"},{"product_id":"dvl-2000-sp6","title":"DVL 2000\/SP6 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation, Output connection cable","description":"\u003ch1\u003e\u003cspan style=\"color: #7baede;\"\u003e\u003cstrong\u003eLEM DVL 2000\/SP6 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation, Output connection cable\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 14kHz\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel Mount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003cli\u003eOutput connection cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVL 2000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 2000V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\n\u003cspan\u003e+\/- \u003c\/span\u003e3000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e50 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e8.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-14 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eOutput connection cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552204102\/LEM\/New%20LEM%20Datasheets\/dvl_2000_sp6.pdf\" title=\"LEM DVL Series Datasheet\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766272627,"sku":"FE-DVL 2000\/SP6","price":609.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvl-2000-sp6-digital-voltage-transducer-vpn-2000v-50ma-output-15-24vdc-powered-8-5kv-isolation-output-connection-cable-6479026094.jpg?v=1610359938"},{"product_id":"dvl-250","title":"DVL 250 Digital Voltage Transducer, Vpn = 250V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #7baede;\"\u003e\u003cstrong\u003eLEM DVL 250 Digital Voltage Transducer, Vpn = 250V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 14kHz\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel Mount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVL 250\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 250V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\n\u003cspan\u003e+\/- \u003c\/span\u003e375V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e50 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e8.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-14 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1583552709\/LEM\/Datasheets\/dvl_250.pdf\" title=\"LEM DVL 250 Series\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766338163,"sku":"FE-DVL 250","price":551.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvl-250-digital-voltage-transducer-vpn-250v-50ma-output-15-24vdc-powered-8-5kv-isolation-6479026159731.jpg?v=1610359942"},{"product_id":"dvl-50","title":"DVL 50 Digital Voltage Transducer, Vpn = 50V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #7baede;\"\u003e\u003cstrong\u003eLEM DVL 50 Digital Voltage Transducer, Vpn = 50V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 14kHz\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel Mount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVL 50\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 50V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\n\u003cspan\u003e+\/- \u003c\/span\u003e 75V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e50 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e8.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-14 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1532671407\/LEM\/Datasheets\/dvl_50.pdf\" title=\"LEM DVL Series Datasheet\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766370931,"sku":"FE-DVL 50","price":551.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvl-50-digital-voltage-transducer-vpn-50v-50ma-output-15-24vdc-powered-8-5kv-isolation-6479026192499.jpg?v=1610359946"},{"product_id":"dvl-500","title":"DVL 500 Digital Voltage Transducer, Vpn = 500V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #7baede;\"\u003e\u003cstrong\u003eLEM DVL 500 Digital Voltage Transducer, Vpn = 500V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 14kHz\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel Mount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVL 500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 500V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\n\u003cspan\u003e+\/- \u003c\/span\u003e 750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e50 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e8.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-14 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1532671405\/LEM\/Datasheets\/DVL_500.pdf\" title=\"LEM DVL Series Datasheet\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766403699,"sku":"FE-DVL 500","price":551.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvl-500-digital-voltage-transducer-vpn-500v-50ma-output-15-24vdc-powered-8-5kv-isolation-6479026290803.jpg?v=1610359950"},{"product_id":"dvl-750","title":"DVL 750 Digital Voltage Transducer, Vpn = 750V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #7baede;\"\u003e\u003cstrong\u003eLEM DVL 750 Digital Voltage Transducer, Vpn = 750V, 50mA output, +\/-15...24VDC powered, 8.5kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 14kHz\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel Mount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVL 750\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 750V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 1125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e50 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e8.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-14 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e270g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1532671403\/LEM\/Datasheets\/dvl_750.pdf\" title=\"LEM DVL Series Datasheet\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766436467,"sku":"FE-DVL 750","price":551.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvl-750-digital-voltage-transducer-vpn-750v-50ma-output-15-24vdc-powered-8-5kv-isolation-6479026323571.jpg?v=1610359954"},{"product_id":"dvm-1000","title":"DVM 1000 Digital Voltage Transducer, Vpn = 1000V, +\/-12...24VDC, 75mA output, 12kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #83b3e1;\"\u003e\u003cstrong\u003eLEM DVM 1000 Digital Voltage Transducer, Vpn = 1000V, +\/-12...24VDC, 75mA output, 12kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 13kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eDigital Transducer\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003cli\u003eDrop in replacement for LV100-1000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVM 1000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 1500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e75 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-13 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e375g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552035134\/LEM\/New%20LEM%20Datasheets\/dvm_1000.pdf\" title=\"LEM DVM Series Datasheet\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766502003,"sku":"FE-DVM 1000","price":929.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvm-1000-digital-voltage-transducer-vpn-1000v-12-24vdc-50ma-output-12kv-isolation-6602079993971.jpg?v=1610359957"},{"product_id":"dvm-2000","title":"DVM 2000 Digital Voltage Transducer, Vpn = 2000V, +\/-12...24VDC, 75mA output, 12kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #83b3e1;\"\u003e\u003cstrong\u003eLEM DVM 2000 Digital Voltage Transducer, Vpn = 2000V, +\/-12...24VDC, 75mA output, 12kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 13kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003cli\u003eDrop in Replacment for \u003ca title=\"LV100-2000\/SP6 Product Page\" href=\"LV100-2000-SP6\" target=\"_blank\"\u003eLV100-2000\/SP6\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003cli\u003eDrop in replacement for LV100-2000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVM 2000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 2000V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 3000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e75 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-13 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e375g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"LEM DVM Series Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552035130\/LEM\/New%20LEM%20Datasheets\/dvm_2000.pdf\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff;\" title=\"LEM Application Manual\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766534771,"sku":"FE-DVM 2000","price":1078.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvm-2000-digital-voltage-transducer-vpn-2000v-12-24vdc-50ma-output-12kv-isolation-6602163716211.jpg?v=1610359961"},{"product_id":"dvm-3000","title":"DVM 3000 Digital Voltage Transducer, Vpn = 3000V, +\/-12...24VDC, 75mA output, 12kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #83b3e1;\"\u003e\u003cstrong\u003eLEM DVM 3000 Digital Voltage Transducer, Vpn = 3000V, +\/-12...24VDC, 50mA output, 12kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 13kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003cli\u003eDrop in replacement for LV100-3000\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVM 3000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 3000V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 4500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e75 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-13 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e375g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556192050\/LEM\/Datasheets\/dvm_3000.pdf\" title=\"LEM DVM Series Datasheet\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766567539,"sku":"FE-DVM 3000","price":1114.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvm-3000-digital-voltage-transducer-vpn-3000v-12-24vdc-50ma-output-12kv-isolation-6602144317555.jpg?v=1610359965"},{"product_id":"dvm-3600","title":"DVM 3600 Digital Voltage Transducer, Vpn = 3600V, +\/-12...24VDC, 75mA output, 12kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #83b3e1;\"\u003e\u003cstrong\u003eLEM DVM 3600 Digital Voltage Transducer, Vpn = 3600V, +\/-12...24VDC, 75mA output, 12kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 13kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003cli\u003eDrop in replacement for LV100-3600\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVM 3600\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 3600V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 5400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e75 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-13 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e375g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"LEM DVM Series Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556191986\/LEM\/Datasheets\/dvm_3600.pdf\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff;\" title=\"LEM Application Manual\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766633075,"sku":"FE-DVM 3600","price":1114.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvm-3600-digital-voltage-transducer-vpn-3600v-12-24vdc-50ma-output-12kv-isolation-6602142810227.jpg?v=1610359969"},{"product_id":"dvm-4000","title":"DVM 4000 Digital Voltage Transducer, Vpn = 4000V, +\/-12...24VDC, 75mA output, 12kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #83b3e1;\"\u003e\u003cstrong\u003eLEM DVM 4000 Digital Voltage Transducer, Vpn = 4000V, +\/-12...24VDC, 75mA output, 12kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 13kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003cli\u003eDrop in replacement for LV100-4000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVM 4000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 4000V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 6000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e75 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-13 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e375g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556191443\/LEM\/Datasheets\/dvm_4000.pdf\" title=\"LEM DVM Series Datasheet\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" title=\"LEM Application Manual\" style=\"color: #0000ff;\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766665843,"sku":"FE-DVM 4000","price":1114.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvm-4000-digital-voltage-transducer-vpn-4000v-12-24vdc-50ma-output-12kv-isolation-6602143891571.jpg?v=1610359972"},{"product_id":"dvm-4000-b","title":"DVM 4000-B Digital Voltage Transducer, Vpn = 4000V, +\/-12...24VDC, 6.66V output, 12kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #83b3e1;\"\u003e\u003cstrong\u003eLEM DVM 4000-B Digital Voltage Transducer, Vpn = 4000V, +\/-12...24VDC, 6.66V output, 12kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 13kHz\u003c\/li\u003e\n\u003cli\u003eDigital Transducer (ASIC based)\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVM 4000-B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/-4000V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 6000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e6.66V @ +\/- Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-13 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw, M5 Inserts on Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e375g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"LEM DVM Series Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1621400394\/LEM\/Datasheets\/dvm_2000_b_to_4000_b_series.pdf\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff;\" title=\"LEM Application Manual\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766698611,"sku":"FE-DVM 4000-B","price":1160.4,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvm-4000-b-digital-voltage-transducer-vpn-4000v-12-24vdc-50ma-output-12kv-isolation-13076347814022.jpg?v=1650937633"},{"product_id":"dvm-4200","title":"DVM 4200 Digital Voltage Transducer, Vpn = 4200V, +\/-12...24VDC, 72mA output, 12kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #83b3e1;\"\u003e\u003cstrong\u003eLEM DVM 4200 Digital Voltage Transducer, Vpn = 4200V, +\/-12...24VDC, 50mA output, 12kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 13kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eDigital Transducer\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003cli\u003eDrop in replacement for LV100-4200\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVM 4200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/-4200V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 6000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e72 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-13 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e0.8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e375g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"LEM DVM Series Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552035130\/LEM\/New%20LEM%20Datasheets\/dvm_4200.pdf\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff;\" title=\"LEM Application Manual\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766731379,"sku":"FE-DVM 4200","price":1114.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvm-4200-digital-voltage-transducer-vpn-4200v-12-24vdc-50ma-output-12kv-isolation-13076347781254.jpg?v=1610359981"},{"product_id":"dvm-600","title":"DVM 600 Digital Voltage Transducer, Vpn = 600V, +\/-12...24VDC, 50mA output, 12kV Isolation","description":"\u003ch1\u003e\u003cspan style=\"color: #83b3e1;\"\u003e\u003cstrong\u003eLEM DVM 600 Digital Voltage Transducer, Vpn = 600V, +\/-12...24VDC, 50mA output, 12kV Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth DC to 13kHz\u003c\/li\u003e\n\u003cli\u003eClosed loop transducer using Hall effect\u003c\/li\u003e\n\u003cli\u003eDigital Transducer\u003c\/li\u003e\n\u003cli\u003eCompact and versatile\u003c\/li\u003e\n\u003cli\u003ePanel\u003cspan\u003e \u003c\/span\u003eMount\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow temperature drift\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eVoltage overload capability\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRailway substation or locomotive\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003cli\u003eWater Treatment Electronics\u003c\/li\u003e\n\u003cli\u003eDrop in replacement for LV100-600\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"1\" frames=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eDVM 600\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5348px;\"\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 28.5348px;\"\u003e+\/-15..24 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003ePrimary Nominal Voltage (RMS + DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan\u003e+\/- 600V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e+\/- 900V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e50 mA @Vpn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eDC-13 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e-40\u003cspan\u003e°C\u003c\/span\u003e \/ 85\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eM5 Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e375g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"LEM DVM Series Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556191286\/LEM\/Datasheets\/dvm_600.pdf\" target=\"_blank\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eApplication Notes\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff;\" title=\"LEM Application Manual\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1556510670\/LEM\/Additional%20Resources\/Application_Notes_-_LEM_basics.pdf\" target=\"_blank\"\u003eLEM Applications Manual 3rd Edition\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766764147,"sku":"FE-DVM 600","price":929.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-dvm-600-digital-voltage-transducer-vpn-600v-12-24vdc-50ma-output-12kv-isolation-6602079371379.jpg?v=1610359985"},{"product_id":"lv-100-100","title":"LV100-100, C\/L Voltage Transducer, 100V, +\/-15VDC Aux, 50mA Output","description":"\u003ch1\u003e\u003cspan style=\"color: #93b5d9;\"\u003e\u003cstrong\u003eLEM LV 100-100 C\/L Voltage Transducer, 100V, +\/-15VDC Aux, 50mA Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated voltage measurement up tp 150VAC\/DC\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) voltage transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway Equipment\u003c\/li\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003eTraction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLV 100-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePrimary RMS Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100V\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 150 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResponse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50uS\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFaston 45° \u003c\/span\u003e\u003cspan\u003e6.3 x 0.8mm\u003c\/span\u003e\u003cspan\u003e and M5 threaded studs\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552034957\/LEM\/New%20LEM%20Datasheets\/LV_100-100_Data_Sheet_2003.02.pdf\" target=\"_blank\" title=\"LEM LV100-100 Series\" rel=\"noopener noreferrer\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766829683,"sku":"FE-LV 100-100","price":879.3,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-lv100-100-c-l-voltage-transducer-100v-15vdc-aux-50ma-output-6479027011699.jpg?v=1610359990"},{"product_id":"lv-100-1000","title":"LV100-1000, C\/L Voltage Transducer, 1000V, +\/-15VDC Aux, 50mA Output","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LV 100-1000 C\/L Voltage Transducer, 1000V, +\/-15VDC Aux, 50mA Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated voltage measurement up tp 1500VAC\/DC\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) voltage transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway Equipment\u003c\/li\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003eTraction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLV 100-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePrimary RMS Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000V\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResponse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40uS\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFaston 45° \u003c\/span\u003e\u003cspan\u003e6.3 x 0.8mm\u003c\/span\u003e\u003cspan\u003e and M5 threaded studs\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552034956\/LEM\/New%20LEM%20Datasheets\/LV_25-1000_Data_Sheet_2006.06.pdf\" title=\"LEM LV100-1000 Series\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766862451,"sku":"FE-LV 100-1000","price":879.3,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-lv100-1000-c-l-voltage-transducer-1000v-15vdc-aux-50ma-output-6479027110003.jpg?v=1610359993"},{"product_id":"lv-100-1200","title":"LV100-1200, C\/L Voltage Transducer, 1200V, +\/-15VDC Aux, 50mA Output","description":"\u003ch1\u003e\u003cspan style=\"color: #93b5d9;\"\u003e\u003cstrong\u003eLEM LV 100-1200 C\/L Voltage Transducer, 1200V, +\/-15VDC Aux, 50mA Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated voltage measurement up tp 1800VAC\/DC\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) voltage transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway Equipment\u003c\/li\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003eTraction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLV 100-1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePrimary RMS Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1200V\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResponse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120uS\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFaston 45° \u003c\/span\u003e\u003cspan\u003e6.3 x 0.8mm\u003c\/span\u003e\u003cspan\u003e and M5 threaded studs\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552034959\/LEM\/New%20LEM%20Datasheets\/LV_100-1200_Data_Sheet_2003.01.pdf\" target=\"_blank\" title=\"LEM LV100-1200 Series\" rel=\"noopener noreferrer\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766895219,"sku":"FE-LV 100-1200","price":879.3,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-lv100-1200-c-l-voltage-transducer-1200v-15vdc-aux-50ma-output-6479027175539.jpg?v=1610359997"},{"product_id":"lv-100-2000","title":"LV 100-2000, C\/L Voltage Transducer, 2000V, +\/-15VDC Aux, 50mA Output","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LV100-2000 C\/L Voltage Transducer, 2000V, +\/-15VDC Aux, 50mA Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated voltage measurement up tp 3000VAC\/DC\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) voltage transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway Equipment\u003c\/li\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003eTraction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLV 100-2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePrimary RMS Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000V\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 3000 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResponse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150uS\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFaston 45° \u003c\/span\u003e\u003cspan\u003e6.3 x 0.8mm\u003c\/span\u003e\u003cspan\u003e and M5 threaded studs\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552034960\/LEM\/New%20LEM%20Datasheets\/LV_100-2000_Data_Sheet_2003.01.pdf\" title=\"LEM LV100-2000 Series\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422766960755,"sku":"FE-LV 100-2000","price":879.3,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-lv100-2000-c-l-voltage-transducer-2000v-15vdc-aux-50ma-output-6479027208307.jpg?v=1610360001"},{"product_id":"lv-100-3500","title":"LV 100-3500, C\/L Voltage Transducer, 3500V, +\/-15VDC Aux, 50mA Output","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM LV 100-3500 C\/L Voltage Transducer, 3500V, +\/-15VDC Aux, 50mA Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated voltage measurement up tp 5250VAC\/DC\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) voltage transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway Equipment\u003c\/li\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003eTraction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLV 100-3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePrimary RMS Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500V\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 5250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResponse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190uS\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFaston 45° \u003c\/span\u003e\u003cspan\u003e6.3 x 0.8mm\u003c\/span\u003e\u003cspan\u003e and M5 threaded studs\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552034951\/LEM\/New%20LEM%20Datasheets\/LV_100-3500_Data_Sheet_2003.05.pdf\" title=\"LEM LV100-3500 Series\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422767026291,"sku":"FE-LV 100-3500","price":935.2,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-lv-100-3500-c-l-voltage-transducer-3500v-15vdc-aux-50ma-output-6479027273843.jpg?v=1610360004"},{"product_id":"lv-100-400","title":"LV100-400, C\/L Voltage Transducer, 400V, +\/-15VDC Aux, 50mA Output","description":"\u003ch1\u003e\u003cspan style=\"color: #93b5d9;\"\u003e\u003cstrong\u003eLEM LV 100-400 C\/L Voltage Transducer, 400V, +\/-15VDC Aux, 50mA Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated voltage measurement up tp 600VAC\/DC\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) voltage transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway Equipment\u003c\/li\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003eTraction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLV 100-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePrimary RMS Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400V\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResponse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80uS\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFaston 45° \u003c\/span\u003e\u003cspan\u003e6.3 x 0.8mm\u003c\/span\u003e\u003cspan\u003e and M5 threaded studs\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552034958\/LEM\/New%20LEM%20Datasheets\/LV_100-400_Data_Sheet_2008.04.pdf\" target=\"_blank\" title=\"LEM LV100-400 Series\" rel=\"noopener noreferrer\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422767059059,"sku":"FE-LV 100-400","price":879.3,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-lv100-400-c-l-voltage-transducer-400v-15vdc-aux-50ma-output-6479027306611.jpg?v=1610360008"},{"product_id":"lv-100-4000","title":"LV100-4000, C\/L Voltage Transducer, 4000V, +\/-15VDC Aux, 50mA Output","description":"\u003ch1\u003e\u003cspan style=\"color: #93b5d9;\"\u003e\u003cstrong\u003eLEM LV 100-4000 C\/L Voltage Transducer, 4000V, +\/-15VDC Aux, 50mA Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated voltage measurement up tp 6000VAC\/DC\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) voltage transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway Equipment\u003c\/li\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003eTraction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLV 100-4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePrimary RMS Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4000V\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 6000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResponse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200uS\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFaston 45° \u003c\/span\u003e\u003cspan\u003e6.3 x 0.8mm\u003c\/span\u003e\u003cspan\u003e and M5 threaded studs\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552034951\/LEM\/New%20LEM%20Datasheets\/LV_100-4000_Data_Sheet_2003.05.pdf\" target=\"_blank\" title=\"LEM LV100-4000 Series\" rel=\"noopener noreferrer\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422767091827,"sku":"FE-LV 100-4000","price":1055.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-lv100-4000-c-l-voltage-transducer-4000v-15vdc-aux-50ma-output-6479027339379.jpg?v=1610360012"},{"product_id":"lv-100-600","title":"LV100-600, C\/L Voltage Transducer, 600V, +\/-15VDC Aux, 50mA Output","description":"\u003ch1\u003e\u003cspan style=\"color: #93b5d9;\"\u003e\u003cstrong\u003eLEM LV 100-600 C\/L Voltage Transducer, 600V, +\/-15VDC Aux, 50mA Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated voltage measurement up tp 900VAC\/DC\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) voltage transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway Equipment\u003c\/li\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003eTraction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLV 100-600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePrimary RMS Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600V\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 900 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResponse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200uS\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFaston 45° \u003c\/span\u003e\u003cspan\u003e6.3 x 0.8mm\u003c\/span\u003e\u003cspan\u003e and M5 threaded studs\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552034958\/LEM\/New%20LEM%20Datasheets\/LV_100-600_Data_Sheet_2003.01.pdf\" target=\"_blank\" title=\"LEM LV100-600 Series\" rel=\"noopener noreferrer\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422767124595,"sku":"FE-LV 100-600","price":879.3,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-lv100-600-c-l-voltage-transducer-600v-15vdc-aux-50ma-output-6479027372147.jpg?v=1610360015"},{"product_id":"lv-100-800","title":"LV100-800, C\/L Voltage Transducer, 800V, +\/-15VDC Aux, 50mA Output","description":"\u003ch1\u003e\u003cspan style=\"color: #93b5d9;\"\u003e\u003cstrong\u003eLEM LV 100-800 C\/L Voltage Transducer, 1500V, +\/-15VDC Aux, 50mA Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar and insulated voltage measurement up tp 1200VAC\/DC\u003c\/li\u003e\n\u003cli\u003eCurrent output\u003c\/li\u003e\n\u003cli\u003eClosed loop (compensated) voltage transducer\u003c\/li\u003e\n\u003cli\u003ePanel mounting\u003c\/li\u003e\n\u003cli\u003eInsulated plastic case recognized according to UL 94-V0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eAdvantages\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eVery good linearity\u003c\/li\u003e\n\u003cli\u003eHigh accuracy\u003c\/li\u003e\n\u003cli\u003eLow offset drift over temperature\u003c\/li\u003e\n\u003cli\u003eWide frequency bandwidth\u003c\/li\u003e\n\u003cli\u003eVery low insertion losses\u003c\/li\u003e\n\u003cli\u003eHigh immunity to external interference\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eRailway Equipment\u003c\/li\u003e\n\u003cli\u003eWindmill Inverters\u003c\/li\u003e\n\u003cli\u003eTest and Measurement\u003c\/li\u003e\n\u003cli\u003eSubstations\u003c\/li\u003e\n\u003cli\u003eAC variable speed drives and servo motor drives\u003c\/li\u003e\n\u003cli\u003eStatic converters for DC motor drives\u003c\/li\u003e\n\u003cli\u003eBattery supplied applications\u003c\/li\u003e\n\u003cli\u003eUninterruptible Power Supplies (UPS)\u003c\/li\u003e\n\u003cli\u003eSwitched Mode Power Supplies (SMPS)\u003c\/li\u003e\n\u003cli\u003ePower supplies for welding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eApplication Domain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003eTraction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #6fa8dc;\"\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eEN 50178:1997\u003c\/li\u003e\n\u003cli\u003eIEC61010-1:2010\u003c\/li\u003e\n\u003cli\u003eUL 508:2010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLEM Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLV 100-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Loop Hall Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eAperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 VDC Bipolar, Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003ePrimary RMS Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800V\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eResponse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100uS\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eMounting Style\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbar Mount (with feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003cspan\u003e°C\u003c\/span\u003e \/ 70\u003cspan\u003e°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFaston 45° \u003c\/span\u003e\u003cspan\u003e6.3 x 0.8mm\u003c\/span\u003e\u003cspan\u003e and M5 threaded studs\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1552034959\/LEM\/New%20LEM%20Datasheets\/LV_100-800_Data_Sheet_2003.01.pdf\" target=\"_blank\" title=\"LEM LV100-800 Series\" rel=\"noopener noreferrer\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"LEM International SA","offers":[{"title":"Default Title","offer_id":18422767157363,"sku":"FE-LV 100-800","price":879.3,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/lem-international-sa-ac-dc-voltage-hall-effect-sensor-lv100-800-c-l-voltage-transducer-800v-15vdc-aux-50ma-output-6479027404915.jpg?v=1610360019"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/collections\/LEM-LV100.jpg?v=1572656825","url":"https:\/\/fastron.com.au\/collections\/lem-hall-effect-voltage-sensors-panel-mount.oembed?page=7","provider":"Fastron Electronics Store ","version":"1.0","type":"link"}