{"title":"DC Surge Protection Device (SPD) for Solar Photo Voltaic Systems and Inverters","description":"\u003ch1 style=\"text-align: left;\"\u003e\u003cspan style=\"color: #6ea4d7;\"\u003e\u003cstrong\u003eDC Surge Protection Device (SPD) for Solar Photo Voltaic Systems and Inverters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIf you’re looking for an excellent range of DC Surge Protection Devices from an industry-leading team, talk to the experts at Fastron Electronics.\u003c\/p\u003e\n\u003cp\u003eOur specialists are leaders in protection of power circuits. As well as providing a great range of products, we can also assist you with a wide range of services, solutions and tech support.\u003c\/p\u003e\n\u003cp\u003eThe DC Surge Protection Devices we provide are ideal for use as surge protectors for Inverters and Photo Voltaic Systems. Available in Type1,Type2, Class !, Class II B,C,D with UL or CB, CE, TUV Approvals.\u003c\/p\u003e\n\u003cp\u003ePlease also see our range of \u003ca title=\"Gas Discharge Tubes Page\" href=\"\/pages\/gas-discharge-tubes\" data-mce-fragment=\"1\" target=\"_blank\" data-mce-href=\"\/pages\/gas-discharge-tubes\"\u003eRaycap\/Varsi Gas Discharge Tubes\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e, which are currently sold on a project basis to OEM's.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWe offer the following Brands\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/varsi-energy-absorbers\" title=\"Raycap Varsi Page\" target=\"_blank\"\u003eRaycap\u003c\/a\u003e - UL, CE, TUV Approvals. \u003c\/p\u003e\n\u003cp\u003eTHOR - CE, CB\u003cspan data-mce-fragment=\"1\"\u003e Appr\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eovals\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFastron OEM - CE, CB Approvals\u003c\/p\u003e\n\u003cp\u003eExplore our products on this page and enjoy the peace of mind that comes with free shipping (available on all orders over $300AUD).\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"Contact Fastron\" href=\"\/pages\/contact-us\" target=\"_blank\"\u003eContact us\u003c\/a\u003e\u003c\/span\u003e for any items not shown or for utility grade Surge protection products.\u003c\/p\u003e\n\n\u003cbr\u003e\n  \u003ch2\u003e FAQ's\u003c\/h2\u003e\n\u003cbr\u003e\n\u003cdiv class=\"faq-tabs\"\u003e\n  \u003cdiv class=\"faq-item active\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e1. What is a DC surge protection device (SPD) and how does it work?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eA DC surge protection device (SPD) is designed to protect power circuits from voltage spikes. It works by diverting excessive surge energy—like those caused by lightning or switching operations—away from sensitive components, especially in photovoltaic systems and inverters.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e2. Where can I buy a reliable DC surge protection device in Australia?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eYou can purchase high-quality DC surge protection devices from Fastron Electronics. We stock a wide range of approved products suitable for inverters and PV systems, backed by technical support and fast shipping across Australia.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e3. What is the difference between a DC SPD and an AC SPD?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eThe key difference lies in the type of current each device is designed to protect. A DC SPD protects direct current systems like solar installations, while an AC SPD is used in alternating current circuits typically found in residential or commercial power grids.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e4. How does a solar SPD protect solar power systems from voltage spikes?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eA solar SPD shields your photovoltaic system by diverting harmful surge currents caused by lightning or grid disturbances. This prevents damage to sensitive components such as inverters and ensures the system’s reliability and longevity.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e5. Can I use a DC surge protection device in my solar power installation?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eYes, DC surge protection devices are specifically designed for use in solar power installations. They help protect inverters and other PV system components from unexpected voltage surges.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e6. What are the applications of solar SPDs in photovoltaic (PV) systems?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eSolar SPDs are used in photovoltaic systems to safeguard equipment like inverters, panels, and control systems from transient overvoltages. They’re crucial for maintaining the efficiency and safety of solar power systems.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e7. How do I install a DC surge protection device in a solar power system?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eDC surge protection devices are typically installed near the inverter or where the DC wiring enters the building. Proper installation should follow safety standards and may require professional assistance for best results.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e8. What voltage ratings are available for DC surge protection devices?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eFastron Electronics offers DC surge protection devices in various voltage ratings suitable for different PV system sizes. These are available in Type 1 and Type 2 classes with CE, UL, CB, and TUV approvals.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e9. What is the typical lifespan of a solar SPD?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eThe lifespan of a solar SPD depends on the frequency and intensity of surges. High-quality SPDs from brands like Raycap or THOR, available at Fastron Electronics, are built to offer long-term protection with proper use.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e10. How do surge protection devices improve the safety and longevity of electrical systems?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eSurge protection devices safeguard electrical systems by diverting dangerous overvoltages. This reduces the risk of equipment failure, data loss, and fire hazards—extending the life of electrical components and improving overall system reliability.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e11. Are DC surge protection devices suitable for high-voltage solar installations?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eYes, DC surge protection devices offered by Fastron Electronics are suitable for high-voltage solar installations. They’re designed to meet rigorous safety and performance standards required in industrial and utility-grade solar systems.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e12. Can a solar SPD be used for both residential and commercial solar systems?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eAbsolutely. Solar SPDs are versatile and can be used in both residential and commercial PV systems to protect against surges and ensure long-term system performance and safety.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e13. Are your DC surge protection devices compliant with Australian electrical standards?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eYes, our DC surge protection devices meet international certifications such as CE, UL, CB, and TUV, which align with Australian electrical standards for safety and reliability.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e14. What are the benefits of using a DC SPD in protecting sensitive solar equipment?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eUsing a DC SPD helps protect sensitive solar equipment like inverters and controllers from transient voltages, ensuring consistent performance, reducing downtime, and preventing costly damage to your PV system.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e15. Do solar SPDs offer protection against both lightning strikes and electrical surges?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eYes, solar SPDs provide robust protection against both lightning-induced surges and other electrical disturbances. They are an essential part of safeguarding your photovoltaic system from unexpected power events.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\n","products":[{"product_id":"t1-1500pv-3-0-s-r","title":"Protec T1-1500PV-3+0-S(-R), 1500VDC Surge Protection Device for Photovoltaic Systems, Type 1, Type 2\/Open Type 1 SPD Listed, with Remote Contact","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eProtec T1-1500PV-3+0-S(-R), 1500VDC Surge Protection Device for Photovoltaic Systems, Type 1, Type 2\/Open Type 1 SPD Listed, with Remote Contact\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eRaycap part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eT1-1500PV-3+0-S(-R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e1500VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 1, Type 2\/Open Type 1 SPD Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV + GDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 12.5kA (10\/350uS), 60kA(8\/20uS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"T1-1500PV-3+0-S(-R), 1500VDC Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1656039686\/Raycap\/G29-00-845_ProTec-T1-1500PV-30-S-R_RevA.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" title=\"Raycap G29 SPD Tester\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raycap","offers":[{"title":"Default Title","offer_id":39803372306566,"sku":"FE-Protec T1-1500PV-3+0-S(-R)","price":174.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/ProTec-T1-1500PV-30-S-1.png?v=1656039623"},{"product_id":"t1-1100pv-3-0-r","title":"Protec T1-1100PV-3+0-R, 1100VDC Surge Protection Device for Photovoltaic Systems, Type 1, Type 2\/Open Type 1 SPD Listed, with Remote Contact","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eProtec T1-1100PV-3+0-R, 1100VDC Surge Protection Device for Photovoltaic Systems, Type 1, Type 2\/Open Type 1 SPD Listed, with Remote Contact\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eRaycap part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eProtec T1-1100PV-3+0-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e1100VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 1, Type 2\/Open Type 1 SPD Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV + GDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 12.5kA (10\/350uS), 60kA(8\/20uS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"T1-1100PV-3+0-R, 1100VDC Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1675325170\/Raycap\/ProTec_T1-1100_1500_PV-3_0-R.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raycap","offers":[{"title":"Default Title","offer_id":40089517359238,"sku":"FE-Protec T1-1100PV-3+0-R","price":169.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/ProTec-T1-1500PV-30-S-1_484ba8e7-73f3-4872-8a5a-0a63ae61a281.png?v=1675325136"},{"product_id":"protec-t1-750pv-s-m-p","title":"ProTec T1-750PV-S-M-P, ProTec Cartridge Replacement. SIDE PLUG In for T1-1500PV-3+0-S(-R)","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003eProTec T1-750PV-S-M-P\u003c\/span\u003e, \u003cspan data-mce-fragment=\"1\"\u003eProTec Cartridge Replacement. SIDE PLUG In for T1-1500PV-3+0-S(-R)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eRaycap part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eProTec T1-750PV-S-M-P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e750VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 1, Type 2\/Open Type 1 SPD Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV + GDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 12.5kA (10\/350uS), 60kA(8\/20uS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1656039686\/Raycap\/G29-00-845_ProTec-T1-1500PV-30-S-R_RevA.pdf\" title=\"T1-1500PV-3+0-S(-R), 1500VDC Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raycap","offers":[{"title":"Default Title","offer_id":40089525911686,"sku":"FE-ProTec T1-750PV-S-M-P","price":127.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/SPDSingle.jpg?v=1675325856"},{"product_id":"protec-t1-750pv-s-p","title":"ProTec T1-750PV-S-P, ProTec Cartridge Replacement. MIDDLE PLUG In for T1-1500PV-3+0-S(-R)","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eProTec T1-750PV-S-P, \u003cspan data-mce-fragment=\"1\"\u003eProTec Cartridge Replacement. MIDDLE PLUG In for T1-1500PV-3+0-S(-R)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eRaycap part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eProTec T1-750PV-S-M-P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e750VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 1, Type 2\/Open Type 1 SPD Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV + GDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 12.5kA (10\/350uS), 60kA(8\/20uS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"T1-1500PV-3+0-S(-R), 1500VDC Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1656039686\/Raycap\/G29-00-845_ProTec-T1-1500PV-30-S-R_RevA.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raycap","offers":[{"title":"Default Title","offer_id":40089528598662,"sku":"FE-ProTec T1-750PV-S-P","price":145.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/SPDSingle_2d33a3a3-71af-4d5c-8d41-a1fda67b7150.jpg?v=1675325962"},{"product_id":"protec-t1-550pv-m-p","title":"ProTec T1-550PV-M-P, ProTec Cartridge Replacement. SIDE PLUG In for ProTec T1-1100PV-3+0-R","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eProTec T1-550PV-M-P, ProTec Cartridge Replacement. SIDE PLUG In for ProTec T1-1100PV-3+0-R\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eRaycap part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eProTec T1-550PV-M-P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e1100VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 1, Type 2\/Open Type 1 SPD Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV + GDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 12.5kA (10\/350uS), 60kA(8\/20uS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1675325170\/Raycap\/ProTec_T1-1100_1500_PV-3_0-R.pdf\" title=\"T1-1100PV-3+0-R, 1100VDC Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raycap","offers":[{"title":"Default Title","offer_id":40089532334214,"sku":"FE-ProTec T1-550PV-M-P","price":35.5,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/SPDSingle_889e168b-71cb-4dd1-b9de-ea5b53a2c1d4.jpg?v=1675326266"},{"product_id":"protec-t1-550pv-p","title":"ProTec T1-550PV-P, ProTec Cartridge Replacement. MIDDLE PLUG In for ProTec T1-1100PV-3+0-R","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eProTec T1-550PV-P, ProTec Cartridge Replacement. MIDDLE PLUG In for ProTec T1-1100PV-3+0-R\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eRaycap part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eProTec T1-550PV-P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e1100VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 1, Type 2\/Open Type 1 SPD Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV + GDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 12.5kA (10\/350uS), 60kA(8\/20uS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1675325170\/Raycap\/ProTec_T1-1100_1500_PV-3_0-R.pdf\" title=\"T1-1100PV-3+0-R, 1100VDC Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raycap","offers":[{"title":"Default Title","offer_id":40089534726278,"sku":"FE-ProTec T1-550PV-P","price":36.5,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/SPDSingle_9195ad31-519b-4ab3-86a5-be9720d2a43b.jpg?v=1675326390"},{"product_id":"spd1-dc-3-1500-40","title":"SPD1-DC\/3-1500\/40, 1500VDC Surge Protection Device for Photovoltaic Systems, Type 2","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eSPD1-DC\/3-1500\/40, 1500VDC Surge Protection Device for Photovoltaic Systems, Type 2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eT1-1500PV-3+0-S(-R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e1500VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan mce-data-marked=\"1\"\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11  (TUV Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1686817915\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/Trent_SPD_DC-1_Datasheet.pdf\" title=\"Trent SPD1-DC\/3\/1500\/40 Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40182623076486,"sku":"FE-SPD1-DC\/3-1500\/40","price":79.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/1500V3POleNew.jpg?v=1698646202"},{"product_id":"spd1-dc-3-1000-40","title":"SPD1-DC\/3-1000\/40, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 2 40kA","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eSPD1-DC\/3-1000\/40, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 2 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eSPD1-DC\/3-1000\/40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e1000VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV, IP40\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11  (TUV Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1686817915\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/Trent_SPD_DC-1_Datasheet.pdf\" title=\"Trent SPD1-DC\/3\/1500\/40 Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40182625501318,"sku":"FE-SPD1-DC\/3-1000\/40","price":69.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/1500V3PoleNew_blur.jpg?v=1698646358"},{"product_id":"spd1-dc-3-500-40","title":"SPD1-DC\/3-500\/40, 500VDC Surge Protection Device for Photovoltaic Systems, Type 2 40kA","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eSPD1-DC\/3-500\/40, 500VDC Surge Protection Device for Photovoltaic Systems, Type 2 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eSPD1-DC\/3-500\/40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e500VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11 (TUV Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1686817915\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/Trent_SPD_DC-1_Datasheet.pdf\" title=\"Trent SPD1-DC\/3\/1500\/40 Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eObsolescence\u003c\/h5\u003e\n\u003cp\u003eOBSOLETE. SEE \u003ca rel=\"noopener\" title=\"FRS3-C40-500R Product Page\" href=\"frs3-c40-500r\" target=\"_blank\"\u003eFRS3-C40-600R\u003c\/a\u003e for replacement\u003c\/p\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40182625534086,"sku":"FE-SPD1-DC\/3-500\/40","price":69.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/1500V3PoleNew_blur_8b8defca-4714-47c8-831e-31b4f8e17aa1.jpg?v=1698646377"},{"product_id":"spd1-dc-3-600-40","title":"SPD1-DC\/3-600\/40, 600VDC Surge Protection Device for Photovoltaic Systems, Type 2 40kA","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eSPD1-DC\/3-600\/40, 600VDC Surge Protection Device for Photovoltaic Systems, Type 2 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eSPD1-DC\/3-600\/40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e600VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11 (TUV Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Trent SPD1-DC\/3\/1500\/40 Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1686817915\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/Trent_SPD_DC-1_Datasheet.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eObsolescence\u003c\/h5\u003e\n\u003cp\u003eOBSOLETE. SEE \u003ca href=\"frs3-c40-600r\" target=\"_blank\" title=\"FRS3-C40-600R Product Page\" rel=\"noopener\"\u003eFRS3-C40-600R\u003c\/a\u003e for replacement\u003c\/p\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" title=\"Raycap G29 SPD Tester\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40287144050822,"sku":"FE-SPD1-DC\/3-600\/40","price":59.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/1500V3PoleNew_blur_e4ad70b6-1179-4f22-a7ce-45a97d40ca46.jpg?v=1698646406"},{"product_id":"spd1-dc-3-750-40","title":"SPD1-DC\/3-750\/40, 750VDC Surge Protection Device for Photovoltaic Systems, Type 2 40kA","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eSPD1-DC\/3-750\/40, 750VDC Surge Protection Device for Photovoltaic Systems, Type 2 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eSPD1-DC\/3-750\/40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e750VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11 (TUV Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1686817915\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/Trent_SPD_DC-1_Datasheet.pdf\" title=\"Trent SPD1-DC\/3\/1500\/40 Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40287156863110,"sku":"FE-SPD1-DC\/3-750\/40","price":64.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/1500V3PoleNew_blur_cae126b9-05ca-4bd8-b281-516352749c41.jpg?v=1698646387"},{"product_id":"fbt-y-pvm-600-rm","title":"FBT Y PVM 600 RM, 600VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFBT Y PVM 600 RM, 600VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFBT Y PVM 600 RM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e600VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC614643-11:GB\/T 18802.11: YD\/T 1235.1, CE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Trent FBT Y PVM 600 RM Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716511459\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FBT_Y_PVM_150-1500_RM_EN.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" title=\"Raycap G29 SPD Tester\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40413871407238,"sku":"FE-FBT Y PVM 600 RM","price":99.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/BTYPVM3Pole_53de09a3-2625-4eda-86e1-750426b79aa9.jpg?v=1716509993"},{"product_id":"fbt-y-pvm-150-rm","title":"FBT Y PVM 150 RM, 150VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFBT Y PVM 150 RM, 150VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFBT Y PVM 150 RM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e150VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC614643-11:GB\/T 18802.11: YD\/T 1235.1, CE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Trent FBT Y PVM 600 RM Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716511459\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FBT_Y_PVM_150-1500_RM_EN.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40413874618502,"sku":"FE-FBT Y PVM 150 RM","price":99.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/BTYPVM3Pole_63ea5fc3-d04b-4634-9fc9-b81461a84f7c.jpg?v=1716510017"},{"product_id":"fbt-y-pvm-1000-rm","title":"FBT Y PVM 1000 RM, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFBT Y PVM 1000 RM, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFBT Y PVM 1000 RM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e1000VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC614643-11:GB\/T 18802.11: YD\/T 1235.1, CE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Trent FBT Y PVM 600 RM Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716511459\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FBT_Y_PVM_150-1500_RM_EN.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40413874651270,"sku":"FE-FBT Y PVM 1000 RM","price":129.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/BTYPVM3Pole_167b5ecd-efae-4b32-938b-e203ecdc30e5.jpg?v=1716510039"},{"product_id":"fbt-y-pvm-1200-rm","title":"FBT Y PVM 1200 RM, 1200VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFBT Y PVM 1200 RM, 1200VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFBT Y PVM 1200 RM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e1200VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11 (TUV Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716511459\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FBT_Y_PVM_150-1500_RM_EN.pdf\" target=\"_blank\" title=\"Trent FBT Y PVM 600 RM Surge Protection Device Datasheet\" rel=\"noopener\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40413875175558,"sku":"FE-FBT Y PVM 1200 RM","price":99.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/BTYPVM3Pole_f31bc853-9285-4bf8-bda1-ce0c10ddcaf5.jpg?v=1716510029"},{"product_id":"fbt-y-pvm-1500-rm","title":"FBT Y PVM 1500 RM, 1500VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFBT Y PVM 1500 RM, 1500VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFBT Y PVM 1500 RM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e1500VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11 (TUV Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Trent FBT Y PVM 600 RM Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716511459\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FBT_Y_PVM_150-1500_RM_EN.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40413875208326,"sku":"FE-FBT Y PVM 1500 RM","price":149.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/BTYPVM3Pole_4810a605-45df-4275-85b4-cf5eb9a1a294.jpg?v=1716510006"},{"product_id":"fbt-b-pvm-600-rm","title":"FBT B PVM 600 RM, 600VDC Surge Protection Device for Photovoltaic Systems, Type 1 (CLass I) + Type 2 (CLass II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFBT B PVM 600 RM, 600VDC Surge Protection Device for Photovoltaic Systems, Type 1 (CLass I) + Type 2 (CLass II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFBT B PVM 600 RM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e600VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 1 (CLass I) + Type 2 (CLass II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC614643-11:GB\/T 18802.11: YD\/T 1235.1, CE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716511461\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/Trent_FBT_B_PVM_150-1000_RM_EN.pdf\" title=\"Trent FBT B PVM 1000 RM Surge Protection Device Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" title=\"Raycap G29 SPD Tester\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":41021949870214,"sku":"FE-FBT B PVM 600 RM","price":129.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/BTYPVM3Pole_7212d2e8-84bc-45df-ab3b-cb794605525f.jpg?v=1716510048"},{"product_id":"fbt-b-pvm-150-rm","title":"FBT B PVM 150 RM, 150VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFBT B PVM 150 RM, 150VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFBT B PVM 150 RM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e150VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC614643-11:GB\/T 18802.11: YD\/T 1235.1, CE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Trent FBT B PVM 1000 RM Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716511461\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/Trent_FBT_B_PVM_150-1000_RM_EN.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" title=\"Raycap G29 SPD Tester\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":41021950460038,"sku":"FE-FBT B PVM 150 RM","price":129.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/BTYPVM3Pole_6b221235-ed55-490f-83a6-41259ba4b24a.jpg?v=1716510059"},{"product_id":"fbt-b-pvm-1000-rm","title":"FBT B PVM 1000 RM, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 1 (CLass I) + Type 2 (CLass II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFBT B PVM 1000 RM, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 1 (CLass I) + Type 2 (CLass II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFBT B PVM 1000 RM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e1000VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 1 (CLass I) + Type 2 (CLass II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC614643-11:GB\/T 18802.11: YD\/T 1235.1, CE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Trent FBT B PVM 1000 RM Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716511461\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/Trent_FBT_B_PVM_150-1000_RM_EN.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":41021950722182,"sku":"FE-FBT B PVM 1000 RM","price":129.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/BTYPVM3Pole_02332d94-38db-46b0-b3a7-88b92d266a98.jpg?v=1716509942"},{"product_id":"frs3-c40-1000r","title":"FRS3-C40-1000R, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (CLass II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFRS3-C40-1000R, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFRS3-C40-1000R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e1000VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 1 (Class I) + Type 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC614643-31:2018 (TUV, CE Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Trent FRS3-C40  Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716510258\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS3-C40_1500V_DC_3P_40kA.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":41027609198726,"sku":"FE-FRS3-C40-1000R","price":119.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/TrentFRS3Type1and2SPDforPV1500VDC800px_67bed8f8-0d17-4479-b582-6eea99040da1.png?v=1716509707"},{"product_id":"frs3-c40-750r","title":"FRS3-C40-750R, 750VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFRS3-C40-750R, 750VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFRS3-C40-750R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e750VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 1 (Class I) + Type 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC614643-31:2018 (TUV, CE Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Trent FRS3-C40  Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716510258\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS3-C40_1500V_DC_3P_40kA.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":41027640328326,"sku":"FE-FRS3-C40-750R","price":109.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/TrentFRS3Type1and2SPDforPV1500VDC800px_58cdade8-9284-4248-80eb-dee712afe602.png?v=1716509656"},{"product_id":"frs3-c40-1200r","title":"FRS3-C40-1200R, 1200VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (CLass II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFRS3-C40-1200R, 1200VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFRS3-C40-1200R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e1200VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 1 (Class I) + Type 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC614643-31:2018 (TUV, CE Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Trent FRS3-C40  Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716510258\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS3-C40_1500V_DC_3P_40kA.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":41027644948614,"sku":"FE-FRS3-C40-1200R","price":129.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/TrentFRS3Type1and2SPDforPV1500VDC800px_e36f65e5-f31d-4f8d-9cea-90bf449cf5e1.png?v=1716509691"},{"product_id":"frs3-c40-1500r","title":"FRS3-C40-1500R, 1500VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFRS3-C40-1500R, 1500VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFRS3-C40-1500R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e1500VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 1 (Class I) + Type 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC614643-31:2018 (TUV, CE Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Trent FRS3-C40  Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716510258\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS3-C40_1500V_DC_3P_40kA.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" title=\"Raycap G29 SPD Tester\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":41027656122502,"sku":"FE-FRS3-C40-1500R","price":139.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/TrentFRS3Type1and2SPDforPV1500VDC800px.png?v=1716509542"},{"product_id":"frs3-c40-500r","title":"FRS3-C40-500R, 500VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFRS3-C40-500R, 500VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFRS3-C40-500R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e500VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 1 (Class I) + Type 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC614643-31:2018 (TUV, CE Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Trent FRS3-C40  Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716510258\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS3-C40_1500V_DC_3P_40kA.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":41517582155910,"sku":"FE-FRS3-C40-500R","price":99.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/TrentFRS3Type1and2SPDforPV1500VDC800px_58cdade8-9284-4248-80eb-dee712afe602.png?v=1716509656"},{"product_id":"frs3-c40-1500r-t2","title":"FRS3-C40-1500R-T2, 1500VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFFRS3-C40-1500R-T2, 1500VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\" style=\"height: 290.75px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003eFRS3-C40-1500R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003e1500VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003eType 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 16.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 16.5833px;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 16.5833px;\"\u003e\u003cspan\u003eString Box, Inverter, Sub Board Only\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 39.1667px;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 39.1667px;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 39.1667px;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 39.1667px;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003e\u003cspan\u003eIEC614643-31:2018 (TUV, CE Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1757649180\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/TRS3_C40_1000VDC_1250VDC_1500VDC_Type_2_DC_SPD.pdf\" title=\"Trent FRS3-C40-T2  Surge Protection Device Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" title=\"Raycap G29 SPD Tester\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":41706863034502,"sku":"FE-FRS3-C40-1500R-T2","price":69.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS3-C40-1500R-T2.jpg?v=1743650387"},{"product_id":"frs2-c40-130r","title":"FRS2-C40-130R, 2 Pole (\"+\",\"-\") Un = 130VDC Type 2 (Class II) Surge Protection Device, 20\/40kA, Pluggable, With Remote Contacts. Uc = 180VDC","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFRS2-C40-130R, 130VDC Surge Protection Device for DC\/Battery Systems, Type 2 (CLass II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFRS2-C40-130R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage (Un)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e130VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eMaximum Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e180VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eVoltage Protection Level (Up)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e\u0026lt;0.8kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 2 (CLass II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eBattery System \/ 120VDC UPS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e180g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC614643-31:2018 (TUV, CE Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1752552199\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS2-C40_Un_130VDC_Uc_180VDC_DC_power_SPD-91mm_height.pdf\" title=\"Trent FRS2-C40  130VDC Surge Protection Device Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" title=\"Raycap G29 SPD Tester\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":42296170217606,"sku":"FE-FRS2-C40-130R","price":69.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS2-C40Un130VDC_Uc180VDCphoto.jpg?v=1752552021"},{"product_id":"frs3-c40-1200r-t2","title":"FRS3-C40-1250R-T2, 1250VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFRS3-C40-1250R-T2, 1250VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\" style=\"height: 290.75px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.4763%; height: 19.5833px;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.382%; height: 19.5833px;\"\u003eFRS3-C40-1250R-T2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.4763%; height: 19.5833px;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.382%; height: 19.5833px;\"\u003eUocst = 1250VDC, Ucpv = 1500VDC \u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.4763%; height: 19.5833px;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.382%; height: 19.5833px;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.4763%; height: 19.5833px;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.382%; height: 19.5833px;\"\u003eType 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 16.5833px;\"\u003e\n\u003ctd style=\"width: 36.4763%; height: 16.5833px;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.382%; height: 16.5833px;\"\u003e\u003cspan\u003eString Box, Inverter, Sub Board Only\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.4763%; height: 19.5833px;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.382%; height: 19.5833px;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.4763%; height: 19.5833px;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.382%; height: 19.5833px;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.4763%; height: 19.5833px;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.382%; height: 19.5833px;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.4763%; height: 19.5833px;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.382%; height: 19.5833px;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 36.4763%; height: 39.1667px;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.382%; height: 39.1667px;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 36.4763%; height: 39.1667px;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.382%; height: 39.1667px;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.4763%; height: 19.5833px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.382%; height: 19.5833px;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.4763%; height: 19.5833px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.382%; height: 19.5833px;\"\u003e\u003cspan\u003eIEC614643-31:2018 (TUV, CE Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1757649180\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/TRS3_C40_1000VDC_1250VDC_1500VDC_Type_2_DC_SPD.pdf\" title=\"Trent FRS3-C40-T2  Surge Protection Device Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" title=\"Raycap G29 SPD Tester\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":42396109996166,"sku":"FE-FRS3-C40-1250R-T2","price":69.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS3-C40-1500R-T2_927779b1-5a32-4464-8720-fc9c0b592db9.jpg?v=1755834774"},{"product_id":"frs3-c40-1000r-t2","title":"FRS3-C40-1000R-T2, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFRS3-C40-1000R-T2, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable style=\"height: 290.75px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003eFRS3-C40-1000R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003e1000VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003eType 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 16.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 16.5833px;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 16.5833px;\"\u003e\u003cspan\u003eString Box, Inverter, Sub Board Only\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 39.1667px;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 39.1667px;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 39.1667px;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 39.1667px;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003e\u003cspan\u003eIEC614643-31:2018 (TUV, CE Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1757649180\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/TRS3_C40_1000VDC_1250VDC_1500VDC_Type_2_DC_SPD.pdf\" title=\"Trent FRS3-C40-T2  Surge Protection Device Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":42434347401350,"sku":"FE-FRS3-C40-1000R-T2","price":55.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS3-C40-1500R-T2.jpg?v=1743650387"},{"product_id":"frs2-c40-500r","title":"FRS2-C40-500R-T2, 500VDC 2 Pole Surge Protection Device for DC\/Solar Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFRS2-C40-500R-T2, 500VDC Surge Protection Device for DC\/Solar Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFRS2-C40-500R-T2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage (Un)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e500VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eMaximum PV Operating Voltage (Ucpv)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e600VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eVoltage Protection Level (Up)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e\u0026lt;1.3kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e2 + 0\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eBattery\/Solar System\/UPS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e400g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC614643-31:2018 (TUV, CE Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1765345981\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS2-C40_Un_500VDC_Uc_600VDC.pdf\" title=\"Trent FRS2-C40 500VDC Surge Protection Device Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" title=\"Raycap G29 SPD Tester\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":42981645746310,"sku":"FE-FRS2-C40-500R-T2","price":69.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS2500VDC.jpg?v=1765346323"},{"product_id":"frs2-c40-750r","title":"FRS2-C40-800R, 800VDC 2 Pole Surge Protection Device for DC\/Solar Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFRS2-C40-800R, 750VDC Surge Protection Device for DC\/Solar Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFRS2-C40-800R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage (Un)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e800VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eMaximum PV Operating Voltage (Ucpv)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e960VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eVoltage Protection Level (Up)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e\u0026lt;3.6kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e2 + 0\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eBattery\/Solar System\/UPS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e400g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC614643-31:2018 (TUV, CE Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Trent FRS2-C40 750VDC Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1765345981\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS2-C40_Un_500VDC_Uc_600VDC.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" title=\"Raycap G29 SPD Tester\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":42981649285254,"sku":"FE-FRS2-C40-800R","price":69.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS2500VDC.jpg?v=1765346323"},{"product_id":"frs2-c40-1000r","title":"FRS2-C40-1000R, 2 Pole, 1000VDC Surge Protection Device for DC\/Solar Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFRS2-C40-1000R, 2 Pole, 1000VDC Surge Protection Device for DC\/Solar Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFRS2-C40-1000R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage (Un)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e1000VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eMaximum PV Operating Voltage (Ucpv)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e1200VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eVoltage Protection Level (Up)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e\u0026lt;4kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 2 (CLass II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eBattery\/Solar System\/UPS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e400g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC614643-31:2018 (TUV, CE Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Trent FRS2-C40 1500VDC Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1765345981\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS2-C40_Un_500VDC_Uc_600VDC.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":42981650268294,"sku":"FE-FRS2-C40-1000R","price":79.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS2500VDC_5f113675-5ef6-430e-a8cf-c58d3069dd3c.jpg?v=1765346215"},{"product_id":"frs2-c40-1500r","title":"FRS2-C40-1500R, 2 Pole 1500VDC Surge Protection Device for DC\/Solar Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFRS2-C40-1500R, 2 Pole 1500VDC Surge Protection Device for DC\/Solar Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFRS2-C40-1500R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage (Un)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e1500VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eMaximum PV Operating Voltage (Ucpv)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e1800VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eVoltage Protection Level (Up)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e\u0026lt;5.2kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 2 (CLass II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eBattery\/Solar System\/UPS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e400g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC614643-31:2018 (TUV, CE Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Trent FRS2-C40 1500VDC Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1765345981\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS2-C40_Un_500VDC_Uc_600VDC.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" title=\"Raycap G29 SPD Tester\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":42981650956422,"sku":"FE-FRS2-C40-1500R","price":79.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS2500VDC_5f113675-5ef6-430e-a8cf-c58d3069dd3c.jpg?v=1765346215"},{"product_id":"frs3-c40-500r-t2","title":"FRS3-C40-500R-T2, 500VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFRS3-C40-500R-T2, 500VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable style=\"height: 290.75px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003eFRS3-C40-500R-T2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003e500VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003eType 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 16.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 16.5833px;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 16.5833px;\"\u003e\u003cspan\u003eString Box, Inverter, Sub Board Only\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 39.1667px;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 39.1667px;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 39.1667px;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 39.1667px;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 35.5263%; height: 19.5833px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%; height: 19.5833px;\"\u003e\u003cspan\u003eIEC614643-31:2018 (TUV, CE Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1757649180\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/TRS3_C40_1000VDC_1250VDC_1500VDC_Type_2_DC_SPD.pdf\" title=\"Trent FRS3-C40-T2  Surge Protection Device Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":43962666549382,"sku":"FE-FRS3-C40-500R-T2","price":55.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS3-C40-1500R-T2.jpg?v=1743650387"},{"product_id":"frs3-c40-150r","title":"FRS3-C40-150R, 150VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFRS3-C40-150R, 150VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFRS3-C40-150R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e500VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 1 (Class I) + Type 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole Imax = 40kA (8\/20uS) 9KA Max, In = 20kA (8\/20uS) 9KA Nominal, Iimp = 8kA (10\/350us)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC614643-31:2018 (TUV, CE Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1778632329\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS3-C40-150R.pdf\" target=\"_blank\" title=\"Trent FRS3-C40-150R  Surge Protection Device Datasheet\" rel=\"noopener\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" title=\"Raycap G29 SPD Tester\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":43978619355270,"sku":"FE-FRS3-C40-150R","price":95.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS3-C40-150R.png?v=1778632945"},{"product_id":"frs3-c40-600r","title":"FRS3-C40-600R, 600VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFRS3-C40-600R, 600VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C\/O CONTACTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFRS3-C40-600R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e600VDC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 1 (Class I) + Type 2 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eString Box, Inverter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e(+)-PE,(-)-PE,(+)-(-) PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES NO\/NC\/COM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e420g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC614643-31:2018 (TUV, CE Approved)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Trent FRS3-C40  Surge Protection Device Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716510258\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS3-C40_1500V_DC_3P_40kA.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":43978661658758,"sku":"FE-FRS3-C40-600R","price":99.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/TrentFRS3Type1and2SPDforPV1500VDC800px_58cdade8-9284-4248-80eb-dee712afe602.png?v=1716509656"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/collections\/ProTec-T1-1500PV-30-S-1.png?v=1656040665","url":"https:\/\/fastron.com.au\/collections\/dc-surge-protection-device-spd-for-solar-photo-voltaic-systems-and-inverters.oembed?page=2","provider":"Fastron Electronics Store ","version":"1.0","type":"link"}