{"title":"Protocol Converters","description":"\u003ch1\u003e\u003cspan style=\"color: #6ea4d7;\"\u003e\u003cstrong\u003eProtocol Converters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFastron Electronics carry various protocol converters to suit our main product lines, including IOT Devices, High end Anybus Modules for Advanced Energy Controllers, Non Isolated \u0026amp; Full Galvanically Isolated RS485 to USB Modules, Common Mode Noise Signal Isolators. \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"\/pages\/contact-us\" title=\"Contact Fastron\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eContact Us\u003c\/a\u003e\u003c\/span\u003e for further information.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","products":[{"product_id":"tcc-82","title":"TCC-82, MOXA Port Powered 4kV RS-232 Serial Isolator","description":"\u003ch1\u003e\u003cspan style=\"color: #6ea4d7;\"\u003e\u003cstrong\u003eMOXA Port Powered 4kV RS-232 Serial Isolator\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6ea4d7;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eRS232 DB9 Male Port Isolator\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eComes with Plug Pack power supply\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003ePort powered or Aux Supply Powered\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eUsed for common mode noise rejections in high dV\/dT environments such as UPS, Trackside Rail Equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e4kV RMS Isolation (1 Min)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAutomatic baud rate detection\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1625010827\/Moxa\/moxa-tcc-82-datasheet-v1.1.pdf\" target=\"_blank\" title=\"Moxa RS232 Port Isolator\" rel=\"noopener noreferrer\"\u003e\u003cspan\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Moxa","offers":[{"title":"Default Title","offer_id":18000251191411,"sku":"FE-TCC-82","price":289.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/moxa-communication-accessories-tcc-82-moxa-port-powered-4kv-rs-232-serial-isolator-5890920710259.jpg?v=1610355850"},{"product_id":"usb-rs485-converter","title":"USB RS485 Converter, Generic 2 Pin USB to RS485 Converter, NON ISOLATED","description":"\u003ch1\u003e\u003cspan style=\"color: #6ea4d7;\"\u003e\u003cstrong\u003eGeneric 2 Pin USB to RS485 Converter. For programming RS485 Devices. NON\u003c\/strong\u003e ISOLATED\u003c\/span\u003e\u003c\/h1\u003e","brand":"Fastron Electronics","offers":[{"title":"Default Title","offer_id":29549863895155,"sku":"FE-USB RS485 Converter","price":15.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/101_0273.jpg?v=1692166201"},{"product_id":"mipack-iskra-meter-programmer","title":"MIPACK Iskra Meter Programmer","description":"\u003cp\u003e\u003cspan style=\"color: #8db4de;\"\u003eMIPACK Iskra Meter Programmer \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUsed with SQ0214, MC Series Meters, and Multifunction Transducers\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUses Iskra MiQuen Software\u003c\/span\u003e\u003c\/p\u003e","brand":"Fastron Electronics","offers":[{"title":"Default Title","offer_id":30257074602118,"sku":"FE-MIPACK Iskra Meter Programmer","price":506.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/fastron-electronics-communication-accessories-mipack-iskra-meter-programmer-12785438621830.jpg?v=1610363503"},{"product_id":"sm61iot-11mqe0","title":"SM61IoT-1100M0, Datalogger with Internal Web page, Universal 85-253VAC, 90-300VDC Supply, 2 Relays, Modbus TCP\/RTU,MQTT,HTTP\/TCP\/UDP\/FTP\/RS485\/RS232\/USB Comms, Email Alarm Feature","description":"\u003cp\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLumel SM61IoT-1100M0, Datalogger with Internal Web page, Universal 85-253VAC, 90-300VDC Supply, 2 Relays, Modbus, Email Alarm Feature TCP\/RTU,MQTT,HTTP\/TCP\/UDP\/FTP\/RS485\/RS232\/USB Comms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMQTT protocol for IoT Applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eInternal Web page\u003c\/li\u003e\n\u003cli\u003e1GB Flash Memory (Optional 8GB)\u003c\/li\u003e\n\u003cli\u003eUSB\/RS232\/RS485\/Ethernet Comms as standard\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eModbus TCP\/RTU,MQTT,HTTP\/TCP\/UDP\/FTP Protocols\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eUniversal 85-253VAC, 90-300VDC Supply\u003c\/li\u003e\n\u003cli\u003eRelays Alarms (Optional Digital Alarms)\u003c\/li\u003e\n\u003cli\u003eEmail Alarm Feature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt in Web Page and FTP Server\u003c\/li\u003e\n\u003cli\u003e2 RS485 Ports or 1 x RS485 and 1 x RS232 Ports\u003c\/li\u003e\n\u003cli\u003e2 Relay Alarms\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eReal Time Clock\u003c\/li\u003e\n\u003cli\u003eSimultaneous Interrogation of Data\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePassword Data Access\u003c\/li\u003e\n\u003cli\u003eEmail Alarm Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 530px; height: 429.062px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLumel Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003eSM61IoT-1100E0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003eCommunication Datalogger and Alarm Unit\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003e\u003cspan\u003e90-300VDC or 85-253VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003e\n\u003cspan\u003eTCP\/RTU,MQTT,HTTP\/TCP\/UDP\/FTP\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003eRS485\/RS232,RS485,USB,Ethernet\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 39.1667px;\"\u003e\u003cstrong\u003eRS485\/RS232 Baud Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 39.1667px;\"\u003e1200,2400,4800,9600,19200,38400,57600,115200 bit\/s\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cb\u003eUSB Baud Rate\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003e115200 bit\/s\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cb\u003eEthernet Baud Rate\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003e10,100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003e3.5kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 259px; height: 19.5833px;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eLanguage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 19.5833px;\"\u003eEnglish and Polish version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5729px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 35.5729px;\"\u003e\u003cstrong\u003eEU Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 35.5729px;\"\u003e\n\u003cp\u003eEN61000, EN61010\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5729px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 35.5729px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 35.5729px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 39.1667px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 39.1667px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003e-20 →+70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587628343\/Lumel\/Datasheets\/SM61IoT_data_sheet.pdf\" title=\"Lumel SM61IoT Series Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587628343\/Lumel\/Datasheets\/SM61IoT_service_manual_rev.D.pdf\" title=\"Lumel SM61IoT Series User Manual\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lumel","offers":[{"title":"Default Title","offer_id":31551385763974,"sku":"FE-SM61IoT-1100E0","price":739.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/sm61iot.jpg?v=1624861454"},{"product_id":"pd9","title":"PD9, Communication Converter RS485 Modbus RTU to Modbus TCP, 5-36VDC Supply","description":"\u003ch1\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLumel PD9, Communication Converter RS485 Modbus RTU to Modbus TCP, 5-36VDC Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eUSB\/RS485\/Ethernet Comms as standard\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eModbus TCP\/RTU Protocols\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e5-36VDC Supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 RS485 Ports or 1 x Ethernet Port, 1 x USB service Port\u003c\/li\u003e\n\u003cli\u003eFree user config software \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 530px;\" rules=\"all\" frames=\"border\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLumel Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003ePD9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eCommunication Datalogger and Alarm Unit\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\u003cspan\u003e5-36VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan\u003eTCP\/RTU\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eRS485Ethernet\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eRS485\/RS232 Baud Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1200,2400,4800,9600,19200,38400,57600,115200 bit\/s\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cb\u003eUSB Baud Rate\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e115200 bit\/s\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cb\u003eEthernet Baud Rate\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e10,100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e3.5kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eEU Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eEN61000, EN61010\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e-20 →+70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1683702963\/Lumel\/Datasheets\/PD9_service_manual.pdf\" target=\"_blank\" title=\"Lumel PD9 Series User Manual\" rel=\"noopener noreferrer\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lumel","offers":[{"title":"Default Title","offer_id":40159201460358,"sku":"FE-PD9","price":249.5,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/PD9_fde58f97-a0ed-4a57-a586-29ef336bbbf2.png?v=1683703022"},{"product_id":"pd20-00m0","title":"PD20 00M0, Industrial Grade USB to RS485 Converter, 115.2kbps, Full Galvanic Isolation","description":"\u003ch3\u003e\u003cspan style=\"color: #6ea4d7;\"\u003e\u003cstrong\u003ePD20 00M0, Industrial Grade USB to RS485 Converter, 115.2kbps, Full Galvanic Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #6ea4d7;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIn PD20 converter are used 2 interfaces (USB, RS485) - galvanically isolated.\u003c\/li\u003e\n\u003cli\u003eUSB interface (type A) – destined for the device communication with the computer.\u003c\/li\u003e\n\u003cli\u003eRS-485 interface - destined for the communication with devices from the object side.\u003c\/li\u003e\n\u003cli\u003eCompliance with the standard USB 1.1 and USB 2.0.\u003c\/li\u003e\n\u003cli\u003eData transmission rate up to 115.2 kbps.\u003c\/li\u003e\n\u003cli\u003eSupport virtual serial port (COM).\u003c\/li\u003e\n\u003cli\u003eBi-directional data transmission (half duplex).\u003c\/li\u003e\n\u003cli\u003eDevice supplied from USB port.\u003c\/li\u003e\n\u003cli\u003eExternal dimension: 76 x 25 x 20mm.\u003c\/li\u003e\n\u003cli\u003eConverter does not interfere into the structure of data transmission and is compatible with many industrial communication protocols.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eDatasheet and User Manual\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1692169382\/Lumel\/Datasheets\/PD20_data_sheet.pdf\" title=\"PD20 Lumel Datasheet\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eDatasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1692169382\/Lumel\/Datasheets\/PD20_service_manual.pdf\" title=\"Lumel PD20 Service Manual\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eService Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lumel","offers":[{"title":"Default Title","offer_id":40216577900678,"sku":"FE-PD20 00M0","price":145.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/PD20_web.png?v=1692169768"},{"product_id":"ebs-t04","title":"EBS-T04, Industrial Serial Device Server 2 x LAN Connections, 9-36VDC 5-15Watt, 4 x RS485 Interfaces and Ethernet for Transparent Protocol Custom Agreeements, Free Configuration Software Tool","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eKingen EBS-T04, Industrial Serial Device Server 2 x LAN Connections, 9-36VDC 5-15Watt, 4 x RS485 Interfaces and Ethernet for Transparent Protocol Custom Agreeements, Free Configuration Software Tool\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRS485\/Ethernet Comms as standard\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eModbus TCP\/RTU Protocols\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e9-36VDC Supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFree Configuration Software \u003c\/li\u003e\n\u003cli\u003e4 x RS485 Ports \u003c\/li\u003e\n\u003cli\u003e2 x Ethernet Ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003eSpecification\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 530px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLumel Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003eEBS-T04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003eCommunication Interface RS485 and Ethernet\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e\u003cspan\u003e9-36VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e\n\u003cspan\u003eTCP\/RTU\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e4 x RS485,2 x Ethernet\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eRS485\/RS232 Baud Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e1200,2400,4800,9600,19200,38400,57600,115200 bit\/s\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cb\u003eUSB Baud Rate\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e115,200 bit\/s\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cb\u003eEthernet Baud Rate\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e10,100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e3.5kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eEU Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e\n\u003cp\u003eEN61000-4-2 Level 3, EN61000-4-5 Level 3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e-20 →+70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1714459047\/KIngen\/Datasheet_of_EBS-T04S_erial_Device_Server_from_Kingnen.pdf\" title=\"Kingen EBS-T04 Series User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eUser Manual\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kingen","offers":[{"title":"Default Title","offer_id":40936628158598,"sku":"FE-EBS-T04","price":595.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/EBS-T02T04_431b15bd-93e1-4a8d-8b5c-9bf22219778c.jpg?v=1715140013"},{"product_id":"ebs-t02","title":"EBS-T02, Industrial Serial Device Server 2 x LAN Connections, 9-36VDC 5-15Watt, 2 x RS485 Interfaces and Ethernet for Transparent Protocol Custom Agreeements, Free Configuration Software Tool","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eKingen EBS-T02, Industrial Serial Device Server 2 x LAN Connections, 9-36VDC 5-15Watt, 2 x RS485 Interfaces and Ethernet for Transparent Protocol Custom Agreeements, Free Configuration Software Tool\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRS485\/Ethernet Comms as standard\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eModbus TCP\/RTU Protocols\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e9-36VDC Supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFree Configuration Software \u003c\/li\u003e\n\u003cli\u003e2 x RS485 Ports \u003c\/li\u003e\n\u003cli\u003e2 x Ethernet Ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003eSpecification\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 530px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLumel Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003eEBS-T02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003eCommunication Interface RS485 and Ethernet\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e\u003cspan\u003e9-36VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e\n\u003cspan\u003eTCP\/RTU\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e2 x RS485,2 x Ethernet\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eRS485\/RS232 Baud Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e1200,2400,4800,9600,19200,38400,57600,115200 bit\/s\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cb\u003eUSB Baud Rate\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e115,200 bit\/s\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cb\u003eEthernet Baud Rate\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e10,100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e3.5kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eEU Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e\n\u003cp\u003eEN61000-4-2 Level 3, EN61000-4-5 Level 3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 222.847px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.486px;\"\u003e-20 →+70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1714459047\/KIngen\/Datasheet_of_EBS-T04S_erial_Device_Server_from_Kingnen.pdf\" title=\"Kingen EBS-T04 Series User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eUser Manual\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kingen","offers":[{"title":"Default Title","offer_id":40936661385350,"sku":"FE-EBS-T02","price":495.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/EBS-T02T04.jpg?v=1715140009"},{"product_id":"2-000-190-015","title":"Ethernet IP Anybus Module, Comms Interface for Thyro PX or Basic Bus Module","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy Ethernet IP Anybus Module, Comms Interface for Thyro PX or Basic Bus Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Connection for up to 8 Power Controllers with 8 Modules\u003c\/li\u003e\n\u003cli\u003eFor Thyro PX or Basic Bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #86b0d4;\"\u003e\u003cstrong\u003eCommunication Options :\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet\/IP\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfibus DPV1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModbus RTU\u003c\/li\u003e\n\u003cli\u003eModbus TCP\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfiNET\u003c\/li\u003e\n\u003cli\u003eEtherCAT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 530px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Numbers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eEthernetIP(2.000.090.015)\u003cbr\u003eProfiNET(2.000.190.011)\u003cbr\u003eModbusTCP(2.000.190.013)\u003cbr\u003eProfibusDPV1(2.000.190.010) ModbusRTU(2.000.190.012) DeviceNet(2.000.190.0014)\u003cbr\u003eEtherCAT(2.000.190.016)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e(Via Basic Bus or Thyro PX) Access to controller setpoints, actual points, and parameters\u003cbr\u003eTransfer of setpoints as float number in physical units\u003cbr\u003eControl Function of LED's\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan\u003eEthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet, EtherCat, Modbus RTU\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cb\u003eApprovals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eCE, UL\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e-20 ???? ??C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e??\u003c\/p\u003e\n\u003ch5\u003eDatasheet and Guides\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Com Bus Module Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41601384743046,"sku":"FE-2.000.190.015","price":577.5,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/dASM_99f22db9-c7b4-48e1-a629-56e3b2b48095.jpg?v=1740034269"},{"product_id":"2-000-190-012","title":"Modbus RTU Anybus Module, Comms Interface for Thyro PX or Basic Bus Module","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy Modbus RTU Anybus Module, Comms Interface for Thyro PX or Basic Bus Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Connection for up to 8 Power Controllers with 8 Modules\u003c\/li\u003e\n\u003cli\u003eFor Thyro PX or Basic Bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #86b0d4;\"\u003e\u003cstrong\u003eCommunication Options :\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet\/IP\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfibus DPV1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModbus RTU\u003c\/li\u003e\n\u003cli\u003eModbus TCP\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfiNET\u003c\/li\u003e\n\u003cli\u003eEtherCAT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 530px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Numbers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eEthernetIP(2.000.090.015)\u003cbr\u003eProfiNET(2.000.190.011)\u003cbr\u003eModbusTCP(2.000.190.013)\u003cbr\u003eProfibusDPV1(2.000.190.010) ModbusRTU(2.000.190.012) DeviceNet(2.000.190.0014)\u003cbr\u003eEtherCAT(2.000.190.016)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e(Via Basic Bus or Thyro PX) Access to controller setpoints, actual points, and parameters\u003cbr\u003eTransfer of setpoints as float number in physical units\u003cbr\u003eControl Function of LED's\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan\u003eEthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet, EtherCat, Modbus RTU\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cb\u003eApprovals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eCE, UL\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e-20 ???? ??C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e??\u003c\/p\u003e\n\u003ch5\u003eDatasheet and Guides\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Com Bus Module Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41601384775814,"sku":"FE-2.000.190.012","price":577.5,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/dASM_9beb162c-e086-4086-a1e2-35ecc5abca24.jpg?v=1740034271"},{"product_id":"2-000-190-013","title":"Modbus TCP Anybus Module, Comms Interface for Thyro PX or Basic Bus Module","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy Modbus TCP Anybus Module, Comms Interface for Thyro PX or Basic Bus Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Connection for up to 8 Power Controllers with 8 Modules\u003c\/li\u003e\n\u003cli\u003eFor Thyro PX or Basic Bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #86b0d4;\"\u003e\u003cstrong\u003eCommunication Options :\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet\/IP\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfibus DPV1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModbus RTU\u003c\/li\u003e\n\u003cli\u003eModbus TCP\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfiNET\u003c\/li\u003e\n\u003cli\u003eEtherCAT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 530px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Numbers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eEthernetIP(2.000.090.015)\u003cbr\u003eProfiNET(2.000.190.011)\u003cbr\u003eModbusTCP(2.000.190.013)\u003cbr\u003eProfibusDPV1(2.000.190.010) ModbusRTU(2.000.190.012) DeviceNet(2.000.190.0014)\u003cbr\u003eEtherCAT(2.000.190.016)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e(Via Basic Bus or Thyro PX) Access to controller setpoints, actual points, and parameters\u003cbr\u003eTransfer of setpoints as float number in physical units\u003cbr\u003eControl Function of LED's\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan\u003eEthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet, EtherCat, Modbus RTU\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cb\u003eApprovals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eCE, UL\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e-20 ???? ??C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e??\u003c\/p\u003e\n\u003ch5\u003eDatasheet and Guides\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Com Bus Module Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41601384841350,"sku":"FE-2.000.190.013","price":577.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/dASM_d571ded7-1794-435d-bf1f-52346cd3258e.jpg?v=1740034273"},{"product_id":"2-000-190-011","title":"Profinet Anybus Module, Comms Interface for Thyro PX or Basic Bus Module","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy Profinet Anybus Module, Comms Interface for Thyro PX or Basic Bus Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Connection for up to 8 Power Controllers with 8 Modules\u003c\/li\u003e\n\u003cli\u003eFor Thyro PX or Basic Bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #86b0d4;\"\u003e\u003cstrong\u003eCommunication Options :\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet\/IP\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfibus DPV1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModbus RTU\u003c\/li\u003e\n\u003cli\u003eModbus TCP\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfiNET\u003c\/li\u003e\n\u003cli\u003eEtherCAT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 530px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Numbers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eEthernetIP(2.000.090.015)\u003cbr\u003eProfiNET(2.000.190.011)\u003cbr\u003eModbusTCP(2.000.190.013)\u003cbr\u003eProfibusDPV1(2.000.190.010) ModbusRTU(2.000.190.012) DeviceNet(2.000.190.0014)\u003cbr\u003eEtherCAT(2.000.190.016)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e(Via Basic Bus or Thyro PX) Access to controller setpoints, actual points, and parameters\u003cbr\u003eTransfer of setpoints as float number in physical units\u003cbr\u003eControl Function of LED's\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan\u003eEthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet, EtherCat, Modbus RTU\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cb\u003eApprovals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eCE, UL\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e-20 ???? ??C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e??\u003c\/p\u003e\n\u003ch5\u003eDatasheet and Guides\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Com Bus Module Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41601384874118,"sku":"FE-2.000.190.011","price":777.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/dASM.jpg?v=1740034274"},{"product_id":"2-000-190-010","title":"Profibus Anybus Module, Comms Interface for Thyro PX or Basic Bus Module","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy Profibus Anybus Module, Comms Interface for Thyro PX or Basic Bus Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Connection for up to 8 Power Controllers with 8 Modules\u003c\/li\u003e\n\u003cli\u003eFor Thyro PX or Basic Bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #86b0d4;\"\u003e\u003cstrong\u003eCommunication Options :\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet\/IP\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfibus DPV1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModbus RTU\u003c\/li\u003e\n\u003cli\u003eModbus TCP\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfiNET\u003c\/li\u003e\n\u003cli\u003eEtherCAT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 530px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Numbers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eEthernetIP(2.000.090.015)\u003cbr\u003eProfiNET(2.000.190.011)\u003cbr\u003eModbusTCP(2.000.190.013)\u003cbr\u003eProfibusDPV1(2.000.190.010) ModbusRTU(2.000.190.012) DeviceNet(2.000.190.0014)\u003cbr\u003eEtherCAT(2.000.190.016)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e(Via Basic Bus or Thyro PX) Access to controller setpoints, actual points, and parameters\u003cbr\u003eTransfer of setpoints as float number in physical units\u003cbr\u003eControl Function of LED's\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan\u003eEthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet, EtherCat, Modbus RTU\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cb\u003eApprovals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eCE, UL\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e-20  to 70C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet and Guides\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Com Bus Module Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41601384906886,"sku":"FE-2.000.190.010","price":577.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/dASM_1683092d-0698-4410-a55f-e961f5eaa5ac.jpg?v=1740034276"},{"product_id":"2-000-190-014","title":"DeviceNet Anybus Module, Comms Interface for Thyro PX or Basic Bus Module","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy DeviceNet Anybus Module, Comms Interface for Thyro PX or Basic Bus Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Connection for up to 8 Power Controllers with 8 Modules\u003c\/li\u003e\n\u003cli\u003eFor Thyro PX or Basic Bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #86b0d4;\"\u003e\u003cstrong\u003eCommunication Options :\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet\/IP\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfibus DPV1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModbus RTU\u003c\/li\u003e\n\u003cli\u003eModbus TCP\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfiNET\u003c\/li\u003e\n\u003cli\u003eEtherCAT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 530px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Numbers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eEthernetIP(2.000.090.015)\u003cbr\u003eProfiNET(2.000.190.011)\u003cbr\u003eModbusTCP(2.000.190.013)\u003cbr\u003eProfibusDPV1(2.000.190.010) ModbusRTU(2.000.190.012) DeviceNet(2.000.190.0014)\u003cbr\u003eEtherCAT(2.000.190.016)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e(Via Basic Bus or Thyro PX) Access to controller setpoints, actual points, and parameters\u003cbr\u003eTransfer of setpoints as float number in physical units\u003cbr\u003eControl Function of LED's\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan\u003eEthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet, EtherCat, Modbus RTU\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cb\u003eApprovals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eCE, UL\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd style=\"width: 259px;\" height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e-20 ???? ??C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e??\u003c\/p\u003e\n\u003ch5\u003eDatasheet and Guides\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Com Bus Module Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" target=\"_blank\"\u003e\u003cspan color=\"#2b00ff\" style=\"color: #2b00ff;\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Ethernet IP Setup Guide\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41601384972422,"sku":"FE-2.000.190.014","price":577.5,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/dASM_edb23497-4acd-4c70-baa9-e71f981d1d1c.jpg?v=1740034278"},{"product_id":"2-000-190-016","title":"EtherCAT Anybus Module, Comms Interface for Thyro PX or Basic Bus Module","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #8db4de;\"\u003eAdvanced Energy EtherCAT Anybus Module, Comms Interface for Thyro PX or Basic Bus Module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptional Connection for up to 8 Power Controllers with 8 Modules\u003c\/li\u003e\n\u003cli\u003eFor Thyro PX or Basic Bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: #86b0d4;\"\u003e\u003cstrong\u003eCommunication Options :\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet\/IP\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfibus DPV1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eModbus RTU\u003c\/li\u003e\n\u003cli\u003eModbus TCP\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProfiNET\u003c\/li\u003e\n\u003cli\u003eEtherCAT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 530px;\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eAdvanced Energy Part Numbers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003eEthernetIP(2.000.090.015)\u003cbr\u003eProfiNET(2.000.190.011)\u003cbr\u003eModbusTCP(2.000.190.013)\u003cbr\u003eProfibusDPV1(2.000.190.010) ModbusRTU(2.000.190.012) DeviceNet(2.000.190.0014)\u003cbr\u003eEtherCAT(2.000.190.016)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e(Via Basic Bus or Thyro PX) Access to controller setpoints, actual points, and parameters\u003cbr\u003eTransfer of setpoints as float number in physical units\u003cbr\u003eControl Function of LED's\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cspan\u003eEthernetIP, Profinet, Modbus TCP ProfibusDPV1, ModbusRTU, DeviceNet, EtherCat, Modbus RTU\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cb\u003eApprovals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e\n\u003cp\u003eCE, UL\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px;\"\u003e-20 ???? ??C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e??\u003c\/p\u003e\n\u003ch5\u003eDatasheet and Guides\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587712547\/Advanced%20Energy\/thyro-family-accessories.pdf\" title=\"Com Bus Module Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348515\/Advanced%20Energy\/Setting_up_Comms_and_BasicBus_Module_on_Thyro_Controllers.pdf\" title=\"Setting up basicbus module Comms fo Thyro A Series Controllers\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eSetting Up Comms on Thyro A Series Controllers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1736728647\/Advanced%20Energy\/thyro-px-software-and-touch-display-user-guide.pdf\" title=\"Thyro Touch Software and Thyro Touch Display User Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\" color=\"#2b00ff\"\u003eThyro Touch Software and Touch Display User Guide\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1716348508\/Advanced%20Energy\/TN1025_-_Initializing_the_Anybus_Ethernet_IP_Basic_Busmodule_2019-04-18.pdf\" title=\"Ethernet IP Setup Guide\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eAnybus Device Ethernet IP Setup Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Advanced Energy","offers":[{"title":"Default Title","offer_id":41601385037958,"sku":"FE-2.000.190.016","price":577.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/dASM_41f49ea0-7e32-4623-a961-096acf17cde4.jpg?v=1740034280"},{"product_id":"sm61iot-2100e0","title":"SM61IoT-2100M0, Datalogger with Internal Web page, Universal 20-40VAC, 20-60VDC Supply, 2 Relays, Modbus TCP\/RTU,MQTT,HTTP\/TCP\/UDP\/FTP\/RS485\/RS232\/USB Comms","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLumel SM61IoT-2100M0, Datalogger with Internal Web page, Universal 20-40VAC, 20-60VDC Supply, 2 Relays, Modbus, Email Alarm Feature TCP\/RTU,MQTT,HTTP\/TCP\/UDP\/FTP\/RS485\/RS232\/USB Comms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMQTT protocol for IoT Applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eInternal Web page\u003c\/li\u003e\n\u003cli\u003e1GB Flash Memory (Optional 8GB)\u003c\/li\u003e\n\u003cli\u003eUSB\/RS232\/RS485\/Ethernet Comms as standard\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eModbus TCP\/RTU,MQTT,HTTP\/TCP\/UDP\/FTP Protocols\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eUniversal 20-40VAC, 20-60VDC Supply\u003c\/li\u003e\n\u003cli\u003eRelays Alarms (Optional Digital Alarms)\u003c\/li\u003e\n\u003cli\u003eEmail Alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt in Web Page and FTP Server\u003c\/li\u003e\n\u003cli\u003e2 RS485 Ports or 1 x RS485 and 1 x RS232 Ports\u003c\/li\u003e\n\u003cli\u003e2 Relay Alarms\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eReal Time Clock\u003c\/li\u003e\n\u003cli\u003eSimultaneous Interrogation of Data\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePassword Data Access\u003c\/li\u003e\n\u003cli\u003eEmail Alarm Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 530px; height: 429.062px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eLumel Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003eSM61IoT-2100M0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003eCommunication Datalogger and Alarm Unit\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003e\u003cspan\u003e20-40VAC, 20-60VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003e\n\u003cspan\u003eTCP\/RTU,MQTT,HTTP\/TCP\/UDP\/FTP\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003eRS485\/RS232,RS485,USB,Ethernet\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 39.1667px;\"\u003e\u003cstrong\u003eRS485\/RS232 Baud Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 39.1667px;\"\u003e1200,2400,4800,9600,19200,38400,57600,115200 bit\/s\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cb\u003eUSB Baud Rate\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003e115200 bit\/s\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cb\u003eEthernet Baud Rate\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003e10,100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cstrong\u003eReal Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003e1min\/month (30ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003e3.5kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 259px; height: 19.5833px;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eLanguage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 19.5833px;\"\u003e English\/Polish Market\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5729px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 35.5729px;\"\u003e\u003cstrong\u003eEU Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 35.5729px;\"\u003e\n\u003cp\u003eEN61000, EN61010\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5729px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 35.5729px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 35.5729px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 39.1667px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 39.1667px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 259px; height: 20px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 270px; height: 20px;\"\u003e-20 →+70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587628343\/Lumel\/Datasheets\/SM61IoT_data_sheet.pdf\" title=\"Lumel SM61IoT Series Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1587628343\/Lumel\/Datasheets\/SM61IoT_service_manual_rev.D.pdf\" title=\"Lumel SM61IoT Series User Manual\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lumel","offers":[{"title":"Default Title","offer_id":41854649434246,"sku":"FE-SM61IoT-2100M0","price":769.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/sm61iot.jpg?v=1624861454"},{"product_id":"mbd","title":"MBD, Communication Converter RS485 Modbus RTU to USB, USB Powered, For Beluk CX Plus Series Power Factor Controller to use Free software","description":"\u003ch3\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eMBD, Communication Converter RS485 Modbus RTU to USB, USB Powered, For Beluk CX Plus Series Power Factor Controller to use Free software\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUSB\/RS485\/Ethernet Comms as standard\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eModbus TCP\/RTU Protocols\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e5-36VDC Supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"color: #3d85c6;\"\u003eFeatures :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 RS485 Ports or 1 x Ethernet Port, 1 x USB service Port\u003c\/li\u003e\n\u003cli\u003eFree user config software \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable style=\"width: 530px; height: 409.479px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd style=\"width: 222.83px; height: 20px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eBeluk Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.503px; height: 20px;\"\u003eMBD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd style=\"width: 222.83px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.503px; height: 20px;\"\u003eRS485 Modbus RTU to USB Communication Converter\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd style=\"width: 222.83px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.503px; height: 20px;\"\u003e\u003cspan\u003e5V USB Powered\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd style=\"width: 222.83px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.503px; height: 20px;\"\u003e\n\u003cspan\u003eTCP\/RTU\/USB\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd style=\"width: 222.83px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.503px; height: 20px;\"\u003eUSB, RS485\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\" height=\"20\"\u003e\n\u003ctd style=\"width: 222.83px; height: 39.1667px;\" height=\"20\"\u003e\u003cstrong\u003eRS485\/RS232 Baud Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.503px; height: 39.1667px;\"\u003e1200,2400,4800,9600,19200,38400,57600,115200 bit\/s\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd style=\"width: 222.83px; height: 20px;\" height=\"20\"\u003e\u003cb\u003eUSB Baud Rate\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.503px; height: 20px;\"\u003e115200 bit\/s\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd style=\"width: 222.83px; height: 20px;\" height=\"20\"\u003e\u003cb\u003eIsolation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.503px; height: 20px;\"\u003e3.5kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd style=\"width: 222.83px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.503px; height: 20px;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd style=\"width: 222.83px; height: 20px;\" height=\"20\"\u003e\u003cspan style=\"color: #6fa8dc;\"\u003e\u003cstrong\u003eFactory Pack Qty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.503px; height: 20px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5729px;\" height=\"20\"\u003e\n\u003ctd style=\"width: 222.83px; height: 35.5729px;\" height=\"20\"\u003e\u003cstrong\u003eEU Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.503px; height: 35.5729px;\"\u003e\n\u003cp\u003eEN61000, EN61010\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5729px;\" height=\"20\"\u003e\n\u003ctd style=\"width: 222.83px; height: 35.5729px;\" height=\"20\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.503px; height: 35.5729px;\"\u003e\n\u003cp\u003eProtection Class II\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\" height=\"20\"\u003e\n\u003ctd style=\"width: 222.83px; height: 39.1667px;\" height=\"20\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.503px; height: 39.1667px;\"\u003ePC\/ABS non combustable-self-extinguishability, complying with UL 94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd style=\"width: 222.83px; height: 20px;\" height=\"20\"\u003e\u003cb\u003eEnclosure Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.503px; height: 20px;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd style=\"width: 222.83px; height: 20px;\" height=\"20\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 300.503px; height: 20px;\"\u003e-20 →+70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1752460812\/Beluk\/blr-cx-plus-modbus-installation-manual.pdf\" title=\"Beluk MBD Series Comms User Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eUser Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Beluk","offers":[{"title":"Default Title","offer_id":42399538217094,"sku":"FE-MBD","price":278.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/MBDConverter_3a18f1f2-7905-4ca2-86f1-4ac23aeeab5c.jpg?v=1756101551"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/collections\/images_1_52a955b2-833e-443e-8f67-2c2e377450dd.jpg?v=1572639486","url":"https:\/\/fastron.com.au\/collections\/communication-accessories.oembed?page=2","provider":"Fastron Electronics Store ","version":"1.0","type":"link"}