{"title":"AC Surge Protection Device (SPD) for AC","description":"\u003ch1 style=\"text-align: left;\"\u003e\u003cspan style=\"color: #6ea4d7;\"\u003e\u003cstrong\u003eAC Surge Protection Device (SPD) for AC Sub Distribution Boards or Main Distribution Boards\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eIf you’re looking for an excellent range of Surge Protection Devices from an industry-leading team, talk to the experts at Fastron Electronics.\u003c\/p\u003e\n\u003cp\u003eOur specialists are leaders in protection of power circuits. As well as providing a great range of products, we can also assist you with a wide range of services, solutions and tech support.\u003c\/p\u003e\n\u003cp\u003eThe Surge Protection Devices we provide are ideal for use as surge protectors. When you need to limit voltage in electrical components and electronic circuits, our range is ideal. Our SPD’s are typically connected between Neutral and Power Earth, or Line to Earth.\u003c\/p\u003e\n\u003cp\u003eExplore our products on this page and enjoy the peace of mind that comes with free shipping (available on all orders over $300AUD).\u003c\/p\u003e\n\u003cp\u003eIf you’re looking for higher ratings, please enquire about or range of \u003ca title=\"Gas Discharge Tubes Page\" href=\"\/pages\/gas-discharge-tubes\" target=\"_blank\"\u003eRaycap\/Varsi Gas Discharge Tubes\u003c\/a\u003e, which are currently sold on a project basis to OEM's.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"\/pages\/contact-us\" title=\"Contact Fastron\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eContact us\u003c\/a\u003e\u003c\/span\u003e for any items not shown or for utility grade Surge protection products.\u003c\/p\u003e\n\u003cp\u003eMore Information on Raycap \u003ca title=\"Raycap \/ Varsi Page\" href=\"\/pages\/varsi-energy-absorbers\" target=\"_blank\"\u003ehere.\u003c\/a\u003e\u003c\/p\u003e\n\n  \u003cbr\u003e\n  \u003ch2\u003e FAQ's\u003c\/h2\u003e\n\u003cbr\u003e\n\u003cdiv class=\"faq-tabs\"\u003e\n  \u003cdiv class=\"faq-item active\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e1. What is a lightning arrestor and how does it protect electrical systems?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eA lightning arrestor protects electrical systems by diverting high-voltage surges, such as lightning strikes, safely to the ground.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e2. Where can I buy a reliable lightning arrestor in Australia?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eYou can buy a reliable lightning arrestor in Australia from Fastron Electronics, a trusted supplier of surge protection solutions.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e3. What is the purpose of an overvoltage protector in electrical circuits?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eAn overvoltage protector limits excessive voltage in a circuit to prevent damage to connected devices and components.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e4. How does a surge protection device prevent damage to electronic equipment?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eA surge protection device (SPD) detects and redirects excess voltage to earth, preventing it from reaching sensitive equipment.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e5. Can I use a lightning arrestor in both residential and industrial applications?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eYes, a lightning arrestor can be used in both residential and industrial setups to protect against high-voltage surges.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e6. How do overvoltage protectors differ from surge protection devices?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eOvervoltage protectors focus on limiting continuous overvoltages, while surge protection devices react to sudden voltage spikes like lightning or switching surges.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e7. Are surge protection devices necessary for all electrical systems?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eYes, surge protection devices are recommended for all electrical systems to ensure safety and protect valuable equipment.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e8. What is the typical lifespan of a lightning arrestor?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eThe lifespan of a lightning arrestor depends on usage and exposure, but regular inspection is advised for ongoing protection.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e9. Can a lightning arrestor be used for both low and high-voltage systems?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eYes, lightning arrestors can be used across low and high-voltage systems depending on the specific rating and application.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e10. Do you offer overvoltage protectors that comply with Australian electrical standards?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eYes, overvoltage protectors available at Fastron Electronics are designed to comply with Australian standards and performance requirements.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e11. How do I install a surge protection device in my electrical system?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eTo install a surge protection device, connect it between neutral and earth or line and earth, according to your system configuration.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e12. Are surge protection devices effective in protecting against lightning strikes?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eYes, surge protection devices help protect against lightning-induced surges by safely diverting excess voltage away from circuits.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e13. What voltage ratings are available for lightning arrestors and surge protectors?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eLightning arrestors and surge protectors are available in various voltage ratings. Contact Fastron Electronics for model-specific details.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e14. Can an overvoltage protector be used with sensitive electronics like computers?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eYes, an overvoltage protector is suitable for protecting sensitive electronics like computers from harmful voltage spikes.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"faq-item\"\u003e\n    \u003cdiv class=\"faq-question\"\u003e15. What are the maintenance requirements for surge protection devices?\u003c\/div\u003e\n    \u003cdiv class=\"faq-answer\"\u003eSurge protection devices should be inspected regularly to ensure functionality and replaced if worn or after major surge events.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\n","products":[{"product_id":"ispro-aq-40-440","title":"ISPRO AQ 40\/440, Class II \/ Type 2 \/ A Surge Protection Device (SPD) 40kA, 440VAC, Stud Mount with PE Wire, for indirect lightning strikes","description":"\u003ch1\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eClass II \/ Type 2 \/ A Surge Protection Device (SPD) 40kA, 440VAC, 1 Pole, Stud Mount with PE wire, for indirect lightning strikes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e \u003cspan style=\"color: #8fbad7;\"\u003eIskra Doo part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eAQ 40\/460\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e440VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eClass II \/ Type 2 \/ A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eOverhead power lines\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL\/N-PE \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eImax up to 40 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"ISPRO Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\" target=\"_blank\" data-mce-href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Iskra Doo","offers":[{"title":"Default Title","offer_id":30275114500230,"sku":"FE-ISPRO AQ 40\/440","price":44.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/iskra-systemi-surge-protection-device-ispro-aq-40-440-surge-protection-device-spd-40ka-440vac-stud-mount-with-pe-wire-for-indirect-lightning-strikes-13277808722054_ae3c0ecc-3502-4920-96bd-7ea364b086e9.jpg?v=1684918547"},{"product_id":"ispro-aq-40-275","title":"ISPRO AQ 40\/275, Class II \/ Type 2 \/ A Surge Protection Device (SPD) 40kA, 275VAC, Stud Mount with PE Wire, for indirect lightning strikes","description":"\u003ch1\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eClass II \/ Type 2 \/ A Surge Protection Device (SPD) 40kA, 275VAC, Stud Mount with PE wire, for indirect lightning strikes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e \u003cspan style=\"color: #8fbad7;\"\u003eIskra Doo part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eAQ 40\/275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eClass II \/ Type 2 \/ A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eOverhead power lines\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL\/N-PE \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eImax up to 40 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\" title=\"ISPRO Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Iskra Doo","offers":[{"title":"Default Title","offer_id":30275114532998,"sku":"FE-ISPRO AQ 40\/275","price":41.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/iskra-systemi-surge-protection-device-ispro-aq-40-440-surge-protection-device-spd-40ka-440vac-stud-mount-with-pe-wire-for-indirect-lightning-strikes-13277808722054.jpg?v=1684918594"},{"product_id":"ispro-cr-40-275","title":"ISPRO CR 40\/275, Class II \/ Type 2 \/ C, Modular Surge Protection Device (SPD) 1 Pole 40kA, 275VAC, DIN Rail Mount. For Sub Distribution Boards","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eIskra ISPRO CR 40\/275, \u003cspan data-mce-fragment=\"1\"\u003eClass II \/ Type 2 \/ C, \u003c\/span\u003eModular Surge Protection Device (SPD) 1 Pole 40kA,440VAC, DIN Rail Mount. For Sub Distribution Boards\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eIskra Doo part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eISPRO CR 40\/275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e275VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e1 (modular, stackable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eClass II \/ Type 2 \/ C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Boards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003e\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL\/N-PE \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV + GDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eImax up to 40 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\" title=\"ISPRO Datasheet\" target=\"_blank\" data-mce-href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Iskra Doo","offers":[{"title":"Default Title","offer_id":34779683094662,"sku":"FE-ISPRO CR 40\/275","price":48.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/iskra-systemi-surge-protection-device-ispro-c-120-440-3-0-modular-surge-protection-device-spd-3-pole-40ka-440vac-din-rail-mount-for-sub-distribution-boards-12813642072198_75ff3ad5-29b_ba40d0c8-3f30-49e9-b088-14a813346c43.jpg?v=1684919224"},{"product_id":"ispro-cr-40-440","title":"ISPRO CR 40\/440, Class II \/ Type 2 \/ C, Modular Surge Protection Device (SPD) with Remote Contacts, 1 Pole 40kA, 440VAC, DIN Rail Mount. For Sub Distribution Boards","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eIskra ISPRO CR 40\/440, \u003cspan data-mce-fragment=\"1\"\u003eClass II \/ Type 2 \/ C, \u003c\/span\u003eModular Surge Protection Device (SPD) with Remote Contacts, 1 Pole 40kA, 440VAC, DIN Rail Mount. For Sub Distribution Boards\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eIskra Doo part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eISPRO CR 40\/440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e440VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e1 (modular, stackable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eClass II \/ Type 2 \/ C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Boards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL\/N-PE \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eImax up to 40 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\" title=\"ISPRO Datasheet\" target=\"_blank\" data-mce-href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Iskra Doo","offers":[{"title":"Default Title","offer_id":34779698954374,"sku":"FE-ISPRO CR 40\/440","price":48.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/iskra-systemi-surge-protection-device-ispro-c-120-440-3-0-modular-surge-protection-device-spd-3-pole-40ka-440vac-din-rail-mount-for-sub-distribution-boards-12813642072198_75ff3ad5-29b.jpg?v=1684919184"},{"product_id":"ispro-k-bsr-75-440-3-0","title":"ISPRO-K BSR 75\/440 (3+0), Class I,II \/ Type 1,2 \/ B,C, Surge Protection Device (SPD) with Remote Contact, 3 Pole 75kA,440VAC, DIN Rail Mount, L\/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eIskra ISPRO-K BSR 75\/440 (3+0), \u003cspan data-mce-fragment=\"1\"\u003eClass I,II \/ Type 1,2 \/ B,C, \u003c\/span\u003eSurge Protection Device (SPD) with Remote Contact, 3 Pole 75kA,440VAC, DIN Rail Mount\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eIskra Doo part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eISPRO-K BSR 75\/440 (3+0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e440VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eClass I,II \/ Type 1,2 \/ B,C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eMain Distribution Boards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL\/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV + GDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eImax up to 75 kA, or 25kA per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\" title=\"ISPRO Datasheet\" target=\"_blank\" data-mce-href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Iskra Doo","offers":[{"title":"Default Title","offer_id":34785325940870,"sku":"FE-ISPRO-K BSR 75\/440 (3+0)","price":419.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/ISPROMAIN4Pole.jpg?v=1624864141"},{"product_id":"ispro-k-bsr-100-440-3-1","title":"ISPRO-K BSR 100\/440 (3+1), Class I,II \/ Type 1,2 \/ B,C, Surge Protection Device (SPD) with Remote Contacts, 3 Pole 100kA, 440VAC, DIN Rail Mount, L\/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eIskra ISPRO-K BSR 100\/440 (3+1), \u003cspan data-mce-fragment=\"1\"\u003eClass I,II \/ Type 1,2 \/ B,C, \u003c\/span\u003eSurge Protection Device (SPD) with Remote Contacts, 3 Pole 100kA, 440VAC, DIN Rail Mount, L\/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eIskra Doo part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eISPRO-K BSR 100\/440 (3+1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e440VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eClass I,II \/ Type 1,2 \/ B,C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eOverhead power lines\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL\/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eAdditional Remote Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV + GDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eImax up to 75 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\" title=\"ISPRO Datasheet\" target=\"_blank\" data-mce-href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Iskra Doo","offers":[{"title":"Default Title","offer_id":34785337573510,"sku":"FE-ISPRO-K BSR 100\/440 (3+1)","price":612.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/ISPROMAIN4Pole_0dc9231c-12b0-4c1c-b82c-93649f1f90c7.jpg?v=1624864151"},{"product_id":"ispro-bsr-25-440","title":"ISPRO BSR 25\/440, Class I, II \/ Type 1,2 \/ B, C, Surge Protection Device (SPD) with Remote Contacts, 1 Pole 25kA,440VAC, DIN Rail Mount, L\/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eIskra ISPRO BSR 25\/440, Class I, II \/ Type 1,2 \/ B, C,  Surge Protection Device (SPD) with Remote Contacts, 3 Pole 37.5kA,440VAC, DIN Rail Mount, L\/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eIskra Doo part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eISPRO BSR 25\/440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e440VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eClass I,II \/ Type 1,2 \/ B,C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan mce-data-marked=\"1\"\u003eMain Distribution Boards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL\/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eAdditional Remote Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eYES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV + GDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eImax up to 25 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"ISPRO Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\" data-mce-href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Iskra Doo","offers":[{"title":"Default Title","offer_id":34785340981382,"sku":"FE-ISPRO BSR 25\/440","price":138.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/ISPRO1PoleMain.jpg?v=1684918676"},{"product_id":"ispro-c-120-275-3-0","title":"ISPRO C 120\/275 (3+0), Class II \/ Type 2 \/ C, Modular Surge Protection Device (SPD) 3 Pole 40kA,275VAC, DIN Rail Mount. For Sub Distribution Boards","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eISPRO C 120\/275 (3+0),\u003cspan data-mce-fragment=\"1\"\u003eClass II \/ Type 2 \/ C,\u003c\/span\u003e Modular Surge Protection Device (SPD) 3 Pole 40kA,275VAC, DIN Rail Mount. For Sub Distribution Boards\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eIskra Doo part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eISPRO C 120\/275 (3+0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e275VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3 (via 3 modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eClass II \/ Type 2 \/ C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Boards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eAdditional Remote Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eNO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL\/N-PE \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV + GDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eImax up to 40 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\" title=\"ISPRO Datasheet\" target=\"_blank\" data-mce-href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Iskra Doo","offers":[{"title":"Default Title","offer_id":39311739027590,"sku":"FE-ISPRO C 120\/275 (3+0)","price":129.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/4PoleSPD_88006c99-b40f-478a-a4cb-d1cd340c6561.jpg?v=1684920827"},{"product_id":"module-ispro-c-40-275","title":"Module ISPRO C 40\/275, Replacement Cartridge for Surge Protection Device (SPD) 1 Pole 40kA, 275VAC, Class II \/ Type 2 \/ C","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eIskra Module ISPRO C 40\/275, Replacement Cartridge for Surge Protection Device (SPD) 1 Pole 40kA, 275VAC, \u003cspan data-mce-fragment=\"1\"\u003eClass II \/ Type 2 \/ C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eIskra Doo part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e786.600.196.000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e275VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eClass II \/ Type 2 \/ C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan mce-data-marked=\"1\"\u003eIn ISPRO Products\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL\/N-PE \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV + GDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eImax up to 40 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\" title=\"ISPRO Datasheet\" target=\"_blank\" data-mce-href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Iskra Doo","offers":[{"title":"Default Title","offer_id":39324348285062,"sku":"FE-Module ISPRO CR 40\/275","price":27.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/ISPROcartridge.jpg?v=1650948031"},{"product_id":"module-ispro-c-40-440","title":"Module ISPRO C 40\/440, Replacement Cartridge for Surge Protection Device (SPD) 1 Pole 40kA, 440VAC","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eIskra Module ISPRO C 40\/440, Replacement Cartridge for Surge Protection Device (SPD) 1 Pole 40kA, 440VAC, \u003cspan data-mce-fragment=\"1\"\u003eClass II \/ Type 2 \/ C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eIskra Doo part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eModule ISPRO C 40\/440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e440VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eClass II \/ Type 2 \/ C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan mce-data-marked=\"1\"\u003eIn ISPRO Products\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL\/N-PE \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV + GDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eImax up to 40 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\" title=\"ISPRO Datasheet\" target=\"_blank\" data-mce-href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1567324843\/Iskra%20Systemi\/Datasheets\/overvoltage-protection-05.pdf\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Iskra Doo","offers":[{"title":"Default Title","offer_id":39324350349446,"sku":"FE-Module ISPRO C 40\/440","price":27.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/ISPROcartridge_dea21c49-efaf-42f2-a086-4a473cd5384e.jpg?v=1650948041"},{"product_id":"st5593d","title":"ST5593D, Surge Protection Device (SPD), 400VAC, Panel Mount with PE Wire, for Direct Lightning strikes","description":"\u003ch1\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eST5593D, Surge Protection Device (SPD), 400VAC, Panel Mount with PE Wire, for Direct Lightning strikes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e Fastron\u003cspan style=\"color: #8fbad7;\"\u003e part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eST5593D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eClass II \/ Type 2 \/ A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSubstation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL\/N-PE  \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eBack to Back Diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eImax up to 200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eN\/A Diode fails to short or open ciruit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n","brand":"Fastron Electronics","offers":[{"title":"Default Title","offer_id":39589155864710,"sku":"FE-ST5593D","price":1149.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/ST5593D_500x500_8b03ecb4-6566-4f00-87db-7ee3fce974ca.png?v=1657683553"},{"product_id":"protec-t1-750-3-0-r","title":"T2 Protec T2-750-3+0-R, 750VAC Surge Protection Device for 600VAC Systems, Type 1, Type 2\/Open Type 1CA, SPD Listed, with Remote Contact","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eProtec Protec T1-750-3+0-R, 750VAC Surge Protection Device for 600VAC Systems, Type 1, Type 2\/Open Type 1CA, SPD Listed, with Remote Contact\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eRaycap part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eProtec Protec T2 Protec T2-750-3+0-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e750VAC (for 600VAC systems)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eType 1, Type 2\/Open Type 1CA SPD Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eSub Distribution Boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan mce-data-marked=\"1\"\u003eL-PEN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV + GDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 20kA (10\/350uS), 60kA(8\/20uS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1688541777\/Raycap\/G29-00-988-OTL-ProTec-T2-30.pdf\" target=\"_blank\" title=\"T2 Protec T2-750-3+0-R Surge Protection Device Datasheet\" rel=\"noopener noreferrer\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" title=\"Raycap G29 SPD Tester\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raycap","offers":[{"title":"Default Title","offer_id":40192191234182,"sku":"FE-T2 Protec T2-750-3+0-R","price":152.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/ProTec-T1-1500PV-30-S-1_b8bbaa52-1338-49c7-b19b-f3df2a198507.png?v=1688541590"},{"product_id":"fgs1-c-1-275-20","title":"FGS1-C\/1-275-20, 275VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFGS1-C\/1-275-20, 275VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFGS1-C\/1-275-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e275VAC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan mce-data-marked=\"1\"\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eClass II, Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL-N,L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1689067437\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/SPD-AC.pdf\" title=\"Trent FGS1-C Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40195089989766,"sku":"FE-FGS1-C\/1-275-20","price":35.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FGS1-CACSPD1Pole.jpg?v=1689067768"},{"product_id":"fgs1-c-2-275-20","title":"FGS1-C\/2-275-20, 275VAC 2 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFGS1-C\/2-275-20, 275VAC 2 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFGS1-C\/2-275-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e275VAC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eClass II, Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL-N,L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1689067437\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/SPD-AC.pdf\" title=\"Trent FGS1-C Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40195091038342,"sku":"FE-FGS1-C\/2-275-20","price":60.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FGS1-CACSPD2Pole.jpg?v=1689067905"},{"product_id":"fgs1-c-3-275-20","title":"FGS1-C\/3-275-20, 275VAC 3 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFGS1-C\/3-275-20, 275VAC 3 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFGS1-C\/3-275-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e275VAC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eClass II, Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL-N,L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1689067437\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/SPD-AC.pdf\" title=\"Trent FGS1-C Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40195091103878,"sku":"FE-FGS1-C\/3-275-20","price":90.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FGS1-CACSPD3Pole.jpg?v=1689068027"},{"product_id":"fgs1-c-4-275-20","title":"FGS1-C\/4-275-20, 275VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFGS1-C\/4-275-20, 275VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFGS1-C\/4-275-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e275VAC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eClass II, Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL-N,L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1689067437\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/SPD-AC.pdf\" title=\"Trent FGS1-C Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40195091234950,"sku":"FE-FGS1-C\/4-275-20","price":120.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FGS1-CACSPD4Pole.jpg?v=1689068135"},{"product_id":"fgs1-c-1-320-20","title":"FGS1-C\/1-320-20, 320VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFGS1-C\/1-320-20, 320VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFGS1-C\/1-320-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e320VAC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan mce-data-marked=\"1\"\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eClass II, Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL-N,L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1689067437\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/SPD-AC.pdf\" title=\"Trent FGS1-C Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40195091464326,"sku":"FE-FGS1-C\/1-320-20","price":35.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FGS1-CACSPD1Pole_0da187f6-ff60-4d9c-ae97-04a1cbf8f353.jpg?v=1689068406"},{"product_id":"fgs1-c-2-320-20","title":"FGS1-C\/2-320-20, 320VAC 2 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFGS1-C\/2-320-20, 320VAC 2 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFGS1-C\/2-320-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e320VAC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eClass II, Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL-N,L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1689067437\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/SPD-AC.pdf\" title=\"Trent FGS1-C Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40195091497094,"sku":"FE-FGS1-C\/2-320-20","price":60.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FGS1-CACSPD2Pole_12bd144c-c273-41fd-9492-1a9955ea09ff.jpg?v=1689068407"},{"product_id":"fgs1-c-3-320-20","title":"FGS1-C\/3-320-20, 320VAC 3 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFGS1-C\/3-320-20, 320VAC 3 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFGS1-C\/3-320-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e320VAC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eClass II, Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL-N,L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1689067437\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/SPD-AC.pdf\" title=\"Trent FGS1-C Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40195091529862,"sku":"FE-FGS1-C\/3-320-20","price":90.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FGS1-CACSPD3Pole_a4225b1e-1179-4a2e-9e94-0e8ec420331b.jpg?v=1689068408"},{"product_id":"fgs1-c-4-320-20","title":"FGS1-C\/4-320-20, 320VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFGS1-C\/4-320-20, 320VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFGS1-C\/4-320-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e320VAC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eClass II, Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL-N,L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1689067437\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/SPD-AC.pdf\" title=\"Trent FGS1-C Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40195091562630,"sku":"FE-FGS1-C\/4-320-20","price":120.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FGS1-CACSPD4Pole_61c086e3-afb7-43cf-86a0-801a99287c00.jpg?v=1689068410"},{"product_id":"fgs1-c-1-385-20","title":"FGS1-C\/1-385-20, 385VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFGS1-C\/1-385-20, 385VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFGS1-C\/1-385-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e385VAC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan mce-data-marked=\"1\"\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eClass II, Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL-N,L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1689067437\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/SPD-AC.pdf\" title=\"Trent FGS1-C Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40195091923078,"sku":"FE-FGS1-C\/1-385-20","price":35.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FGS1-CACSPD1Pole.jpg?v=1689068411"},{"product_id":"fgs1-c-2-385-20","title":"FGS1-C\/2-385-20, 385VAC 2 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFGS1-C\/2-385-20, 385VAC 2 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFGS1-C\/2-385-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e385VAC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eClass II, Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL-N,L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1689067437\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/SPD-AC.pdf\" title=\"Trent FGS1-C Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40195091955846,"sku":"FE-FGS1-C\/2-385-20","price":60.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FGS1-CACSPD2Pole.jpg?v=1689068413"},{"product_id":"fgs1-c-3-385-20","title":"FGS1-C\/3-385-20, 385VAC 3 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFGS1-C\/3-385-20, 385VAC 3 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFGS1-C\/3-385-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e385VAC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eClass II, Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL-N,L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1689067437\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/SPD-AC.pdf\" title=\"Trent FGS1-C Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40195091988614,"sku":"FE-FGS1-C\/3-385-20","price":90.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FGS1-CACSPD3Pole.jpg?v=1689068414"},{"product_id":"fgs1-c-4-385-20","title":"FGS1-C\/4-385-20, 385VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)","description":"\u003ch1\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFGS1-C\/4-385-20, 385VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFGS1-C\/4-385-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e385VAC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eClass II, Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL-N,L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1689067437\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/SPD-AC.pdf\" title=\"Trent FGS1-C Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40195092021382,"sku":"FE-FGS1-C\/4-385-20","price":120.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FGS1-CACSPD4Pole.jpg?v=1689068416"},{"product_id":"fgs1-c-1-440-20","title":"FGS1-C\/1-440-20, 440VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFGS1-C\/1-440-20, 440VAC 1 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFGS1-C\/1-440-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e440VAC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eClass II, Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL-N,L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1689067437\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/SPD-AC.pdf\" title=\"Trent FGS1-C Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40195092054150,"sku":"FE-FGS1-C\/1-440-20","price":35.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FGS1-CACSPD1Pole_d73df2e5-709c-432f-8002-51f5c3d36d45.jpg?v=1689068417"},{"product_id":"fgs1-c-2-440-20","title":"FGS1-C\/2-440-20, 440VAC 2 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFGS1-C\/2-440-20, 440VAC 2 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFGS1-C\/2-440-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e440VAC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eClass II, Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL-N,L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1689067437\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/SPD-AC.pdf\" title=\"Trent FGS1-C Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40195092086918,"sku":"FE-FGS1-C\/2-440-20","price":60.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FGS1-CACSPD2Pole_514191b1-051e-4ccc-8832-ff0b3379c5f7.jpg?v=1689068418"},{"product_id":"fgs1-c-3-440-20","title":"FGS1-C\/3-440-20, 440VAC 3 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFGS1-C\/3-440-20, 440VAC 3 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFGS1-C\/3-440-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e440VAC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eClass II, Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL-N,L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1689067437\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/SPD-AC.pdf\" title=\"Trent FGS1-C Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40195092119686,"sku":"FE-FGS1-C\/3-440-20","price":90.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FGS1-CACSPD3Pole_e77b8b81-2f26-4833-b122-f97c1f57e7d9.jpg?v=1689068420"},{"product_id":"fgs1-c-4-440-20","title":"FGS1-C\/4-440-20, 440VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA (max)","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eFGS1-C\/4-440-20, 440VAC 4 Pole Surge Protection Device for Sub Distribution Boards, Class II, Type 2, 40kA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFGS1-C\/4-440-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e440VAC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eClass II, Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eSub Distribution Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL-N,L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo Fault\/Fault Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eGreen Flag \/ Not Green Flag\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003ePer pole 40kA (8\/20uS)9KA) Max, 20kA (8\/20uS)9KA) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC50539-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1689067437\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/SPD-AC.pdf\" title=\"Trent FGS1-C Surge Protection Device Datasheet\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGDT\/MOV\/TVS Tester\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Raycap G29 SPD Tester\" href=\"https:\/\/fastron-electronics-store.myshopify.com\/admin\/products\/g29-00-159-prosct\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSPD Tester\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":40195092152454,"sku":"FE-FGS1-C\/4-440-20","price":120.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/products\/FGS1-CACSPD4Pole_b62fde9a-6878-4c4b-bd35-205c36a85ce1.jpg?v=1689068421"},{"product_id":"fbt-p-bcm12-5-275-rm-3-0","title":"FBT P BCM12.5 275 RM (3+0), Class I,II \/ Type 1,2 \/ B,C, AC Surge Protection Device (SPD) with Remote Contacts, 3 Pole 37.5kA,440VAC, DIN Rail Mount, L\/N-PE, L-PEN, L-N, N-PE High Energy MOV Type","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eTrent  FBT P BCM12.5 275 RM (3+0), Class I,II \/ Type 1,2 \/ B,C, AC Surge Protection Device (SPD) with Remote Contacts, 3 Pole 37.5kA,440VAC, DIN Rail Mount, L\/N-PE, L-PEN, L-N, N-PE High Energy MOV Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 89.3762%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003eFBT P BCM12.5 275 RM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e440VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e\u003cspan\u003eClass I,II \/ Type 1,2 \/ B,C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e\u003cspan\u003eMain Distribution Boards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e\u003cspan\u003eL\/N-PE, L-PEN, L-N, N-PE High Energy MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e\u003cspan\u003eImax up to 37.5 kA(10\/350us) \/ 100kA(8\/20us) or 12.5kA(10\/350us) \/ 60kA(8\/20us) per pole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1720086258\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FBT_PCM12.5_275_RM_Eng_150px.pdf\" title=\"FBT P BCM AC APD Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":41180205416582,"sku":"FE-FBT P BCM12.5 275 RM\/3P","price":169.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FBT_P_BCM_12.5_275_RM_3_0.jpg?v=1720735075"},{"product_id":"fbt-p-bcm12-5-275-rm-3-0-modules","title":"FBT P BCM12.5 275 RM (3+0 Modules), MODULES ONLY for Class I,II \/ Type 1,2 \/ B,C, AC Surge Protection Device (SPD), 12.5KA\/60kA per Pole","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eTrent FBT P BCM12.5 275 RM (3+0) (Modules), MODULES ONLY for Class I,II \/ Type 1,2 \/ B,C, AC Surge Protection Device (SPD), 12.5KA\/60kA per Pole\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFBT P BCM12.5 275 RM (3+0 Modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e440VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eClass I,II \/ Type 1,2 \/ B,C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eMain Distribution Boards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL\/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eImax up to 37.5 kA(10\/350us) \/ 100kA(8\/20us) or 12.5kA(10\/350us) \/ 60kA(8\/20us) per pole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"FBT P BCM AC APD Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1720086258\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FBT_PCM12.5_275_RM_Eng_150px.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":41203659997318,"sku":"FE-FBT P BCM12.5 275 RM (3+0 Modules)","price":224.4,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/SPD_Cartridge.png?v=1720404723"},{"product_id":"fbt-p-bcm12-5-275-rm-4-0","title":"FBT P BCM12.5 275 RM (4+0), Class I,II \/ Type 1,2 \/ B,C, AC Surge Protection Device (SPD) with Remote Contacts, 3 Pole 37.5kA,440VAC, DIN Rail Mount, L\/N-PE, L-PEN, L-N, N-PE High Energy MOV Type","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eTrent FBT P BCM12.5 275 RM (4+0), Class I,II \/ Type 1,2 \/ B,C, AC Surge Protection Device (SPD) with Remote Contacts, 3 Pole 37.5kA,440VAC, DIN Rail Mount, L\/N-PE, L-PEN, L-N, N-PE High Energy MOV Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 89.3762%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003eFBT P BCM12.5 275 RM (4+0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e440VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e\u003cspan\u003eClass I,II \/ Type 1,2 \/ B,C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e\u003cspan\u003eMain Distribution Boards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e\u003cspan\u003eL\/N-PE, L-PEN, L-N, N-PE High Energy MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\n\u003cb data-mce-fragment=\"1\"\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e\u003cspan\u003eImax up to 37.5 kA(10\/350us) \/ 100kA(8\/20us) or 12.5kA(10\/350us) \/ 60kA(8\/20us) per pole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1722238902\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FBT_P_BCM12.5_..._RM_4P.pdf\" title=\"FBT P BCM AC APD Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":41267503005830,"sku":"FE-FBT P BCM12.5 275 RM (4+0)","price":189.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FBT_BCM_4_Pole.jpg?v=1722238972"},{"product_id":"frs4-c40-1p-n-3p-n-275vac","title":"FRS4-C40 3P+N 230V (R), Class II\/Type 2, AC Surge Protection Device (SPD) with Remote Contacts, 3 Pole In = 20\/50kA L-N ,440VAC, DIN Rail Mount, L\/N-PE, L-PEN, L-N, N-PE High Energy MOV Type","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eTrent FRS4-C40 3P+N 230V (R), Class II\/Type 2, AC Surge Protection Device (SPD) with Remote Contacts, 3 Pole In = 20\/50kA L-N, DIN Rail Mount, L\/N-PE, L-PEN, L-N, N-PE High Energy MOV Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 89.3762%; height: 313.385px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 19.5833px;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 19.5833px;\"\u003eFRS4-C40 3P+N 230V (R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 19.5833px;\"\u003e\u003cstrong\u003eNominal Voltage (Un)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 19.5833px;\"\u003e230VAC L-N, 400VAC L-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.3762%;\"\u003e\u003cstrong\u003eMaximum Operating Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%;\"\u003e\u003cspan\u003e320VAC L-N\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 19.5833px;\"\u003e\u003cstrong\u003eVoltage Protection Level (Up)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 19.5833px;\"\u003e\u003cspan\u003e\u0026lt;1.5kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 19.5833px;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 19.5833px;\"\u003e\u003cspan\u003e3 + 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 19.5833px;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 19.5833px;\"\u003e\u003cspan\u003eClass II \/ Type 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 39.1667px;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 39.1667px;\"\u003e\u003cspan\u003eSub Distribution Boards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 19.5833px;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 19.5833px;\"\u003e\u003cspan\u003eL\/N-PE, L-PEN, L-N, N-PE High Energy MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.184px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 39.184px;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 39.184px;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 19.5833px;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 19.5833px;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.184px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 39.184px;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 39.184px;\"\u003e\u003cspan\u003eImax up to 50kA(8\/20us) L-N 320VAC \/ 65kA(8\/20us) 255VAC N-PE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.184px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 39.184px;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 39.184px;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 19.5833px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 19.5833px;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1752718770\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS4-C40.pdf\" title=\"FRS4-C40 1P+N\/3P+N 230VAC Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":41517616758918,"sku":"FE-FRS4-C40 3P+N 320VAC (R)","price":109.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS4-C403P_N-1.jpg?v=1737347415"},{"product_id":"frs7-b-c-37-5-440-3-0","title":"FRS7-B+C 37.5\/440 (3+0), Class I,II \/ Type 1,2 \/ B,C, Surge Protection Device (SPD), 3 Pole 37.5kA (12.5kA per pole), 440VAC, DIN Rail Mount, L\/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eTrent FRS7-B+C 37.5\/440 (3+0), Class I,II \/ Type 1,2 \/ B,C, Surge Protection Device (SPD), 3 Pole 37.5kA (12.5kA per pole), 440VAC, DIN Rail Mount, L\/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFRS7-B+C 37.5\/440 (3+0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage (Un) L-L\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e400VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eMaximum Voltage (Uc) L-L\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e440VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eVoltage Protection Level (Up)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e\u0026lt;2.2kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eClass I,II \/ Type 1,2 \/ B,C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eMain Distribution Boards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL\/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV + GDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eImax up to 50 kA, or 12.5kA per pole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Trent FRS7 Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1741149459\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS7-B_C.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Iskra Doo","offers":[{"title":"Default Title","offer_id":41620276248710,"sku":"FE-FRS7-B+C 37.5\/440 (3+0)","price":109.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS7-B_C12.5kA.jpg?v=1741149239"},{"product_id":"frs7-b-c-37-5-440-3-0r","title":"FRS7-B+C 37.5\/440 (3+0)R, Class I,II \/ Type 1,2 \/ B,C, Surge Protection Device (SPD), 3 Pole 37.5kA (12.5kA per pole), 440VAC, DIN Rail Mount, With Remote Contacts, L\/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eTrent FRS7-B+C 37.5\/440 (3+0)R, Class I,II \/ Type 1,2 \/ B,C, Surge Protection Device (SPD), 3 Pole 37.5kA (12.5kA per pole), 440VAC, DIN Rail Mount, With Remote Contacts, L\/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eFRS7-B+C 37.5\/440 (3+0)R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNominal Voltage (Un) L-L\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e400VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eMaximum Voltage (Uc) L-L\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e440VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eVoltage Protection Level (Up)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003e\u0026lt; 2.2kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eClass I,II \/ Type 1,2 \/ B,C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eMain Distribution Boards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eL\/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003eMOV + GDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eImax up to 50 kA, or 12.5kA per pole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.5263%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.8421%;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1741149459\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS7-B_C.pdf\" title=\"Trent FRS7 Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Iskra Doo","offers":[{"title":"Default Title","offer_id":41900690014342,"sku":"FE-FRS7-B+C 37.5\/440 (3+0)R","price":169.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS7-B_C12.5kA.jpg?v=1741149239"},{"product_id":"frs4-c40-320v-1p-1-0","title":"FRS4-C40 320V 1P (1+0) (R), Class II\/Type 2, AC Surge Protection Device (SPD), 1 Pole In = 20\/50kA L-N, L\/N-PE, Un = 230VAC, Uc = 320VAC, DIN Rail Mount, High Energy MOV Type, with Remote Contacts","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eTrent FRS4-C40 320V 1P (1+0) (R), Class II\/Type 2, AC Surge Protection Device (SPD), 1 Pole In = 20\/50kA L-N, L\/N-PE, Un = 230VAC, Uc = 320VAC, DIN Rail Mount, High Energy MOV Type, with Remote Contacts\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 89.3762%; height: 274.313px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003eFRS4-C40 230V 1P (1+0) (R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eNominal Voltage (Un)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003e230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.387%;\"\u003e\u003cstrong\u003eMaximum Operating Voltage (Uc(\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%;\"\u003e\u003cspan\u003e320VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.387%;\"\u003e\u003cstrong\u003eVoltage Protection Level (Up)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%;\"\u003e\u003cspan\u003e\u0026lt;1.5kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003e\u003cspan\u003eClass II \/ Type 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003e\u003cspan\u003eSub Distribution Boards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003e\u003cspan\u003eL\/N-PE,  High Energy MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 39.1875px;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 39.1875px;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 39.1875px;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 39.1875px;\"\u003e\u003cspan\u003eImax up to 40kA(8\/20us) L\/N-PE 320VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 39.1875px;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 39.1875px;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1752718770\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS4-C40.pdf\" title=\"FRS4-C40 1P+N\/3P+N 230VAC Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":42307152576646,"sku":"FE-FRS4-C40 320V 1P (1+0) (R)","price":39.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS4-C40320VAC1P-1.jpg?v=1752717512"},{"product_id":"frs4-c40-320v-2p-2-0-r","title":"FRS4-C40 320V 2P (2+0) (R), Class II\/Type 2, AC Surge Protection Device (SPD) with Remote Contacts, 2 Pole In = 20\/50kA L-N, 230VAC, DIN Rail Mount, L\/N-PE, High Energy MOV Type","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eTrent FRS4-C40 320V 2P (2+0) (R), Class II\/Type 2, AC Surge Protection Device (SPD) with Remote Contacts, 2 Pole In = 20\/50kA L-N, Un = 230VAC, Uc = 320VAC, DIN Rail Mount, L\/N-PE, High Energy MOV Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 89.3762%; height: 313.385px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003eFRS4-C40 320V 2P (2+0) (R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cstrong\u003eNominal Voltage (Un)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003e230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cstrong\u003eMaximum Operating Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003e\u003cspan\u003e320VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cstrong\u003eVoltage Protection Level (Up)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003e\u003cspan\u003e\u0026lt;1.5kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003e\u003cspan\u003eClass II \/ Type 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003e\u003cspan\u003eSub Distribution Boards \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003e\u003cspan\u003eL\/N-PE,  High Energy MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.184px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 39.184px;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 39.184px;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.184px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 39.184px;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 39.184px;\"\u003e\u003cspan\u003eImax up to 40kA(8\/20us) L\/N-PE 320VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.184px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 39.184px;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 39.184px;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1752718770\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS4-C40.pdf\" title=\"FRS4-C40 1P+N\/3P+N 230VAC Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":42467941613702,"sku":"FE-FRS4-C40 320V 2P (2+0) (R)","price":55.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS4D20320V2PR.jpg?v=1775717788"},{"product_id":"frs4-c40-480ac-r","title":"FRS4-C40\/480VAC (R), 4 Pole, Uc = 480VAC L-L 960VAC, L-PE 1360VAC, Type 2 (Class II) Surge Protection Device In 20kA, Imax 40kA, Pluggable, With 4 x Remote Contacts","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eTrent FRS4-C40\/480VAC (R),4 Pole, Uc = 480VAC L-L 960VAC, L-PE 1360VAC, Type 2 (Class II) Surge Protection Device In 20kA, Imax 40kA, Pluggable, With 4 x Remote Contacts\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 89.3762%; height: 313.333px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 19.5833px;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 19.5833px;\"\u003eFRS4-C40 3P+N 480VAC (R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 19.5833px;\"\u003e\u003cstrong\u003eNominal Voltage (Un)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 19.5833px;\"\u003e480VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 19.5833px;\"\u003e\u003cstrong\u003eMaximum Operating Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 19.5833px;\"\u003e\u003cspan\u003eL-L : 960 V AC ; L-PE : 880VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 19.5833px;\"\u003e\u003cstrong\u003eVoltage Protection Level (Up)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 19.5833px;\"\u003e\u003cspan\u003eL-L: ≤ 3.8kV; L-PE: ≤ 5.1kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 19.5833px;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 19.5833px;\"\u003e\u003cspan\u003e3 + 0\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 19.5833px;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 19.5833px;\"\u003e\u003cspan\u003eClass II \/ Type 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 19.5833px;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 19.5833px;\"\u003e\u003cspan\u003eSub Distribution Boards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 19.5833px;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 19.5833px;\"\u003e\u003cspan\u003eL-L L-PE, High Energy MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 39.1667px;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 39.1667px;\"\u003e\u003cspan\u003eYES (4x)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 19.5833px;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 19.5833px;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 39.1667px;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 39.1667px;\"\u003e\u003cspan\u003eImax up to 40kA(8\/20us) L-PE\/L-L 320VAC \/ 20kA(8\/20us) L-PE\/L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 39.1667px;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 39.1667px;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.3762%; height: 19.5833px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.3353%; height: 19.5833px;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1764051374\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS4-C40-480_AC.pdf\" title=\"FRS4-C40\/480 Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":42948867883142,"sku":"FE-FRS4-C40\/480VAC (R)","price":119.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS4-C40_480AC.jpg?v=1764051321"},{"product_id":"frs4-c40-350ac-r","title":"FRS4-C40\/350VAC (R), 4 Pole, Un = 240VAC, Uc = 350VAC, Type 2 (Class II) Surge Protection Device In 20kA, Imax 40kA, Pluggable, With Remote Contacts","description":"\u003ch3\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003e Trent FRS4-C40\/350VAC (R), 4 Pole, Un = 240VAC, Uc = 350VAC, Type 2 (Class II) Surge Protection Device In 20kA, Imax 40kA, Pluggable, With Remote Contacts\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 89.3762%; height: 274.313px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 19.5938px;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 19.5938px;\"\u003eFRS4-C40\/350VAC (R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 19.5938px;\"\u003e\u003cstrong\u003eNominal Voltage (Un)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 19.5938px;\"\u003e240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.4019%;\"\u003e\u003cstrong\u003eMaximum Operating Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%;\"\u003e\u003cspan\u003e350VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.4019%;\"\u003e\u003cstrong\u003eVoltage Protection Level (Up)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%;\"\u003e\u003cspan\u003e\u0026lt;1.75kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 19.5938px;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 19.5938px;\"\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 19.5938px;\"\u003e\u003cspan\u003eClass II \/ Type 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 19.5938px;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 19.5938px;\"\u003e\u003cspan\u003eSub Distribution Boards \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 19.5938px;\"\u003e\u003cspan\u003eL-L L-PE, High Energy MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 39.1875px;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 39.1875px;\"\u003e\u003cspan\u003eYES (1 x CO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 19.5938px;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 39.1875px;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 39.1875px;\"\u003e\u003cspan\u003eImax up to 40kA(8\/20us) L-PE\/L-L 350VAC \/ 20kA(8\/20us) L-PE\/L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 39.1875px;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 39.1875px;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 19.5938px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 19.5938px;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1764051374\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS4-C40-480_AC.pdf\" title=\"FRS4-C40\/480 Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":43702142861446,"sku":"FE-FRS4-C40\/350VAC (R)","price":119.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS4-C40-350-R.jpg?v=1773179753"},{"product_id":"frs4-b50-150-r-3p-n","title":"FRS4-B50\/150\/R 3P+N, 4 Pole, Un = 120VAC, Uc = 150VAC, Type 2 (Class II) Surge Protection Device In 20kA, Imax 50kA, Pluggable, With Remote Contacts","description":"\u003ch3\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003e Trent FRS4-B50\/150\/R 3P+N, 4 Pole, Un = 120VAC, Uc = 150VAC, Type 2 (Class II) Surge Protection Device In 20kA, Imax 50kA, Pluggable, With Remote Contacts\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 89.3762%; height: 274.313px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 19.5938px;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 19.5938px;\"\u003eFRS4-B50\/150\/R 3P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 19.5938px;\"\u003e\u003cstrong\u003eNominal Voltage (Un)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 19.5938px;\"\u003e120VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.4019%;\"\u003e\u003cstrong\u003eMaximum Operating Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%;\"\u003e\u003cspan\u003e150VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.4019%;\"\u003e\u003cstrong\u003eVoltage Protection Level (Up)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%;\"\u003e\u003cspan\u003e\u0026lt;1.25kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 19.5938px;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 19.5938px;\"\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 19.5938px;\"\u003e\u003cspan\u003eClass II \/ Type 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 19.5938px;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 19.5938px;\"\u003e\u003cspan\u003eSub Distribution Boards \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 19.5938px;\"\u003e\u003cspan\u003eL-L, L-PE, High Energy MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 39.1875px;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 39.1875px;\"\u003e\u003cspan\u003eYES (1 x CO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 19.5938px;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 39.1875px;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 39.1875px;\"\u003e\u003cspan\u003eImax up to 40kA(8\/20us) L-PE\/L-L 350VAC \/ 20kA(8\/20us) L-PE\/L-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 39.1875px;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 39.1875px;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.4019%; height: 19.5938px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.2989%; height: 19.5938px;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1773957977\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS4-B50_AC_T2_SPD_150V_3P.pdf\" title=\"FRS4-B50\/150 Datasheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":43725394444422,"sku":"FE-FRS4-B50\/150\/R 3P+N","price":119.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS4-B50_150_3_1_Type_II.jpg?v=1773960740"},{"product_id":"frs4-d20-320v-2p-2-0-r","title":"FRS4-D20 320V 2P (2+0) (R), Class II\/Type 2, AC Surge Protection Device (SPD) with Remote Contacts, 2 Pole In = 10\/20kA L-N, 230VAC, DIN Rail Mount, L\/N-PE, High Energy MOV Type","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eTrent FRS4-D20 320V 2P (2+0) (R), Class II\/Type 2, AC Surge Protection Device (SPD) with Remote Contacts, 2 Pole In = 10\/20kA L-N, 230VAC, DIN Rail Mount, L\/N-PE, High Energy MOV Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 89.3762%; height: 313.385px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003eFRS4-D20 320V 2P (2+0) (R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cstrong\u003eNominal Voltage (Un)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003e230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cstrong\u003eMaximum Operating Voltage (Uc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003e\u003cspan\u003e320VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cstrong\u003eVoltage Protection Level (Up)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003e\u003cspan\u003e\u0026lt;1.2kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003e\u003cspan\u003eClass II \/ Type 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003e\u003cspan\u003eSub Distribution Boards \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003e\u003cspan\u003eL\/N-PE,  High Energy MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.184px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 39.184px;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 39.184px;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.184px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 39.184px;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 39.184px;\"\u003e\u003cspan\u003eImax up to 20kA(8\/20us) L\/N-PE 320VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.184px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 39.184px;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 39.184px;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5833px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5833px;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"FRS4-C40 1P+N\/3P+N 230VAC Datasheet\" href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1752718770\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS4-C40.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":43850633052294,"sku":"FE-FRS4-D20 320V 2P (2+0) (R)","price":45.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS4D20320V2PR.jpg?v=1775717788"},{"product_id":"frs4-c40-385v-1p-1-0-r","title":"FRS4-C40 385V 1P (1+0) (R), Class II\/Type 2, AC Surge Protection Device (SPD), Un = 320VAC, Uc = 385VAC, 1 Pole In = 20\/50kA L-N, L\/N-PE, DIN Rail Mount, High Energy MOV Type, with Remote Contacts","description":"\u003ch3\u003e\u003cspan style=\"color: #87b3d7;\"\u003e\u003cstrong\u003eTrent FRS4-C40 385V 1P (1+0) (R), Class II\/Type 2, AC Surge Protection Device (SPD), Un = 320VAC, Uc = 385VAC, 1 Pole In = 20\/50kA L-N, L\/N-PE, DIN Rail Mount, High Energy MOV Type, with Remote Contacts\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #8bb5d7;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 89.3762%; height: 274.313px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cspan style=\"color: #67b0e2;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #8fbad7;\"\u003eTrent part number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003eFRS4-C40 385V 1P (1+0) (R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eNominal Voltage (Un)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003e320VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.387%;\"\u003e\u003cstrong\u003eMaximum Operating Voltage (Uc(\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%;\"\u003e\u003cspan\u003e385VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.387%;\"\u003e\u003cstrong\u003eVoltage Protection Level (Up)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%;\"\u003e\u003cspan\u003e\u0026lt;1.5kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eNo of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory IEC \/ EN \/ VDE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003e\u003cspan\u003eClass II \/ Type 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eLocation of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003e\u003cspan\u003eSub Distribution Boards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtection modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003e\u003cspan\u003eL\/N-PE,  High Energy MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 39.1875px;\"\u003e\n\u003cb\u003eAdditional Remote Contacts\u003c\/b\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 39.1875px;\"\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtective element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003eMOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 39.1875px;\"\u003e\u003cstrong\u003eSurge discharge rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 39.1875px;\"\u003e\u003cspan\u003eImax up to 40kA(8\/20us) L\/N-PE 385VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 39.1875px;\"\u003e\u003cstrong\u003eInternal protection and safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 39.1875px;\"\u003e\u003cspan\u003eThermal disconnector in each MOV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.387%; height: 19.5938px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.4232%; height: 19.5938px;\"\u003e\u003cspan\u003eIEC\/EN 61643-11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDatasheet\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/fastron-electronics\/image\/upload\/v1780616331\/Fastron%20Stuff\/Low%20Voltage%20Switchgear\/FRS4-C40-385R-T2_WEB.pdf\" target=\"_blank\" title=\"FRS4-C40 1P 320VAC Datasheet\" rel=\"noopener\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eProduct Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Trent","offers":[{"title":"Default Title","offer_id":44034406285446,"sku":"FE-FRS4-C40 385V 1P (1+0) (R)","price":39.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/files\/FRS4-C40-385R-T2.jpg?v=1780615714"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0032\/1834\/2003\/collections\/4_Pole_SPD.png?v=1689121965","url":"https:\/\/fastron.com.au\/collections\/ac-surge-protection-device-spd-for-ac.oembed?page=3","provider":"Fastron Electronics Store ","version":"1.0","type":"link"}